52 resultados para HEAT EXCHANGER EFFICIENCY
Resumo:
Pós-graduação em Engenharia Mecânica - FEG
Resumo:
Pós-graduação em Engenharia Mecânica - FEIS
Resumo:
This work aims to verify and compare the efficiency of heat exchangers used in the thermal systems laboratory at Faculdade de Engenharia do Campus de Guaratinguetá - UNESP. Basically, it has been studied two types of heat exchangers: plate type, operating in parallel flow and counter-flow, shell and tube type and also operating in parallel flow and counter flow. Initially it has been presented the didactic equipment and procedures for use of these heat exchangers in the proposed experiments. With the results obtained from the experiments, comparisons were made in order to define the behavior of the heat exchangers regarding some variables. In the study, one comes to the conclusion that the results from shell and tube type of heat exchanger, used in the thermal systems lab, are superior in all conditions analyzed
Resumo:
Stricter environmental policies are shown necessary to ensure an effective pollutant emission control. It is expected for the present year of 2015, that Brazil will assume, at the 21th United Nation's Climate Change Conference (COP21), implementation of commitment to a low carbon economy. This positioning affects the industrial environment, so that is deemed necessary to search for new technologies, less aggressive to the environment, so the adequacies to the new emission policies do not cause a negative effect on production. Almost all of the processes performed in the steel industry demand burning fuel and, therefore, flue gases are sent to the atmosphere. In this present work is discussed the utilization of heat exchangers so, by recovering part of the available heat from the flue gases of certain industrial process, the combustion air is preheated. The combustion air preheat results in less energy requirement, i.e., less need of fuel consumption and, in addition, minor amount of pollutants to be emitted. Due to better fitting to the process, it is studied the utilization of spiral plate heat exchangers. The heat exchanger dimensioning is made by an iterative method implemented in the software Microsoft Excel. Subsequently are analyzed the gains in terms of process's thermal efficiency improvement and the percentage of fuel saving. The latter implies in reduction of the same percentage of greenhouse gases emission
Resumo:
This article presents empirical correlations to predict the density, specific heat, thermal conductivity and rheological power-law parameters of liquid egg yolk over a temperature range compatible with its industrial thermal processing (0-61 C). Moreover, a mathematical model for a pasteurizer that takes into account the spatial variation of the overall heat transfer coefficient throughout the plate heat exchanger is presented, as are two of its simplified forms. The obtained correlations of thermophysical properties are applied for the simulation of the egg yolk pasteurization, and the obtained temperature profiles are used for evaluating the extent of thermal inactivation. A detailed simulation example shows that there is a considerable deviation between the designed level of heat treatment and that this is predicted through process simulation. It is shown that a reliable mathematical model, combined with specialized thermophysical property correlations, provide a more accurate design of the pasteurization equipment that ensures effective inactivation, while preserving nutritional and sensorial characteristics.
Resumo:
A method for studying the technical and economic feasibility of absorption refrigeration systems in compact cogenerators is presented. The system studied consists of an internal combustion engine, an electric generator and a heat exchanger to recover residual heat from the refrigeration water and exhaust gases. As an application, a computer program simulates the cogeneration system in a building which already has 75 kW of installed electric power. The maximum electric and refrigeration demands are 45 kW and 76 kW respectively. This study simulates the system performance, utilizing diesel oil, sugar cane alcohol and natural gas as possible fuels. (C) 1997 Elsevier B.V. Ltd.
Resumo:
Laminar-forced convection inside tubes of various cross-section shapes is of interest in the design of a low Reynolds number heat exchanger apparatus. Heat transfer to thermally developing, hydrodynamically developed forced convection inside tubes of simple geometries such as a circular tube, parallel plate, or annular duct has been well studied in the literature and documented in various books, but for elliptical duct there are not much work done. The main assumptions used in this work are a non-Newtonian fluid, laminar flow, constant physical properties, and negligible axial heat diffusion (high Peclet number). Most of the previous research in elliptical ducts deal mainly with aspects of fully developed laminar flow forced convection, such as velocity profile, maximum velocity, pressure drop, and heat transfer quantities. In this work, we examine heat transfer in a hydrodynamically developed, thermally developing laminar forced convection flow of fluid inside an elliptical tube under a second kind of a boundary condition. To solve the thermally developing problem, we use the generalized integral transform technique (GITT), also known as Sturm-Liouville transform. Actually, such an integral transform is a generalization of the finite Fourier transform, where the sine and cosine functions are replaced by more general sets of orthogonal functions. The axes are algebraically transformed from the Cartesian coordinate system to the elliptical coordinate system in order to avoid the irregular shape of the elliptical duct wall. The GITT is then applied to transform and solve the problem and to obtain the once unknown temperature field. Afterward, it is possible to compute and present the quantities of practical interest, such as the bulk fluid temperature, the local Nusselt number, and the average Nusselt number for various cross-section aspect ratios.
Resumo:
Evaporative cooling operates using water and air as working fluids. It consists in water evaporation, through the passage of an airflow, thus decreasing the air temperature. This system has a great potential to provide thermal comfort in places where air humidity is low, being, however, less efficient where air humidity is high. A way to solve this problem is to use dehumidifiers to pre-conditioning the process air. This paper presents a system that can be used in humid climates coupling desiccant dehumidification equipment to evaporative coolers. The paper shows, initially, the main characteristics of the evaporative cooling and of the adsorption dehumidification systems. Later on the coupled systems, in which occurs a dehumidification by adsorption in a counter flow rotary heat exchanger following the evaporate cooling of the air in evaporative coolers, are analyzed. The thermodynamic equations of state are also presented. Following, this paper analyzes some operation parameters such as: reactivation temperature, R/P relationship (reactivation air flow/ process air flow) and the thermodynamic conditions of the entering air flow. The paper shows the conditions for the best operation point, with regard to thermal comfort conditions and to the energy used in the process. In addition this paper presents an application of the system in different climate characteristics of several tropical and equatorial cities. Copyright © 2005 by ABCM.
Resumo:
An experimental apparatus containing a domestic refrigerator coupled to a vertical hot water storage tank was used for energy recovery. The original condenser of the refrigerator was maintained, but modified with a concentric tubes heat exchanger with countercurrent water and refrigerating gas flows. The coefficient of performance for the heat pump is calculated by the ratio of energy in the heat storage and the electric power consumed by the domestic refrigerator compressor. The results show that the increasing of hydrostatic pressure in the storage tank increases the water flow rate and the coefficient of performance. The proposed device also reduces the heat dissipation to the surroundings. This is more important in small confinements found in low-cost houses.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)