64 resultados para GEOPHYSICS
Resumo:
In order to evaluate the use of shallow seismic technique to delineate geological and geotechnical features up to 40 meters depth in noisy urban areas covered with asphalt pavement, five survey lines were conducted in the metropolitan area of São Paulo City. The data were acquired using a 24-bit, 24-channel seismograph, 30 and 100 Hz geophones and a sledgehammer-plate system as seismic source. Seismic reflection data were recorded using a CMP (common mid point) acquisition method. The processing routine consisted of: prestack band-pass filtering (90-250 Hz); automatic gain control (AGC); muting (digital zeroin) of dead/noisy traces, ground roll, air-wave and refracted-wave; CMP sorting; velocity analyses; normal move-out corrections; residual static corrections; f-k filtering; CMP stacking. The near surface is geologically characterized by unconsolidated fill materials and Quaternary sediments with organic material overlying Tertiary sediments with the water table 2 to 5 m below the surface. The basement is composed of granite and gneiss. Reflections were observed from 40 milliseconds to 65 ms two-way traveltime and were related to the silt clay layer and fine sand layer contact of the Tertiary sediments and to the weathered basement. The CMP seismic-reflection technique has been shown to be useful for mapping the sedimentary layers and the bedrock of the São Paulo sedimentary basin for the purposes of shallow investigations related to engineering problems. In spite of the strong cultural noise observed in these urban areas and problems with planting geophones we verified that, with the proper equipment, field parameters and particularly great care in data collection and processing, we can overcome the adverse field conditions and to image reflections from layers as shallow as 20 meters.
Resumo:
The University of British Columbia (UBC) began performing piezocone penetration tests (CPTU) with electrical resistivity measurements (RCPTU) in 1989. Since then, RCPTU research at UBC has focused on obtaining geo-environmental parameters such as fluid resistivity and soil engineering properties such as porosity and degree of saturation from measurements of bulk soil electrical resistivity using the empirical relationship proposed by Archie (1942). Within this framework, the paper illustrates and discusses important design and calibration issues for resistivity modules such as the use of isolated circuitry to achieve linear calibrations over large ranges of resistivity. The suitability of RCPTU measurements for determination of geo-environmental and geotechnical parameters are assessed using typical ranges of soil and groundwater properties and methods of isolating individual factors for study are discussed. Illustrative examples of RCPTU research efforts including the environmental characterization of mine tailings, delineation of saline water intrusions in fresh water aquifers and the quality control of geotechnical ground densification are presented throughout the text. It is shown that groundwater temperature and hence ion mobility is not significantly altered by frictional heat generated during piezocone penetration and that ratio-based approaches to monitoring soil porosity can be used to eliminate the requirement for extensive groundwater sampling programs. Lastly, it is shown that RCPTU measurements above the water table can only be made using resistivity modules that are stable over a large range of resistivities and that such measurements are the most difficult to interpret because of grain surface conduction effects and generally unknown fluid resistivities.
Resumo:
This study was developed on the basis of petrophysics characterization, 3D seismic interpretation, and rock-wire-log integration. The results were integrated with amplitude attribute through cross plot (rock attribute x amplitude value). 3D seismic data also allowed inteipreting the top of Lagoa Feia, Macaé, and Carapebus formations, and Outeiro Member. The analyses of the maps of structures and attributes, integrated with wire-log data, suggest that Namorado turbidite level is candidate to be mapped with stratigraphic attributes like AverageTroughAmplitude, RMS velocity and Total AbsoluteAmplitude. Lagoa Feia Formation attribute maps (Dip-Azimuth and TotalEnergy) allows to interpret a low fault density at the carbonate coquina level in the Namorado field. This level is also considered one at the best seismic reflector and an important reservoir of the Campos Basin.
Resumo:
This paper presents two case histories from Brazil where geophysical and resistivity piezocone tests were carried out to detect contamination. At the first one, the site investigation program was carried out to detect salt-water intrusions in a superficial sedimentary aquifer, at the Paranaguá harbor, in Paraná State. The second case history is a sanitary landfill from Bauru City, São Paulo State. In both sites, superficial geophysical tests were interpreted to detect and delineate the shape of contamination plume, helping to locate the resistivity piezocone tests. It was found that the interpretation of resistivity piezocone tests is straightforward to assess salt-water intrusion in sedimentary sands. For tropical soils, this technique presented some limitations since the groundwater table sometimes is deeper than the layer penetratable to the cone. Moreover, the genesis of those soils affects soil behavior and soil and water sampling is required to support interpretation.
Resumo:
This paper presents the results of a geophysical study carried out in northeastern São Paulo State and southwestern Minas Gerais State over an area 80 km wide and 97.5 km long in SE Brazil. The Bouguer anomaly map, and geological and structural data allowed to identify three different gravity domains - crustal blocks limited by major discontinuities -related to the structural pattern of the area. These discontinuities were interpreted as geosuture zones underlying the Paraná Basin sediments which have extensions in the Pre-cambrian Basement. The crustal discontinuities named Alterosa and Ribeirão Preto may be seen as A - type collision sutures in a triple junction arramgement. Two prominent linear anomalies are recognized in the Bouguer anomaly map, as well as the limit between the Brasilia and São Paulo crustal blocks or paleoplates. The Alterosa suture zone trends NW-SE while the Ribeirão Preto suture has a NE-SW direction. The Bouguer anomaly map provides subsidies and information on new concepts and theories leading to the refinement of tectonic models.
Resumo:
Vertical electrical soundings using eletroresistivity method were carried out in the public waste landfill in Macapá - AP, having as a goal to investigate the geoelectrical and hidrogeologic characteristics of the ground. The results of geophysics interpretation allowed obtaining a model of five geoelectrical layers until the depth of 14,6 m. This model is correlated to a sedimentary sequence of clay-silt-sandy with laterite. The main flow of the water table, also determined, is concordant to the topographical gradient.
Resumo:
The definition of models and base parameters for application of investigation tools in environment with high complexity are a basic premise to any sciences. The geophysics is a science with solid theoretical base and applications in diversified areas of the sciences geological, astronomical, meteorological, among many others. Its application in environmental studies is relatively recent and needs further research. To understand the behavior of resident contaminants in a dynamic and complex environment as the geological, it requests studies in scale laboratorial, under control of factors seasonality variable. This work simulates a leak of gasoline in soil, under conditions and in laboratory scale, with the objective of monitoring the temporary behavior of the hydrocarbon under the optics of variation of the parameter physical electric resistivity. The results indicate increase of the resistivity in recent periods the contamination, followed for stability in the values and finally fall and return tendency to the natural conditions.
Resumo:
In geophysics and seismology, raw data need to be processed to generate useful information that can be turned into knowledge by researchers. The number of sensors that are acquiring raw data is increasing rapidly. Without good data management systems, more time can be spent in querying and preparing datasets for analyses than in acquiring raw data. Also, a lot of good quality data acquired at great effort can be lost forever if they are not correctly stored. Local and international cooperation will probably be reduced, and a lot of data will never become scientific knowledge. For this reason, the Seismological Laboratory of the Institute of Astronomy, Geophysics and Atmospheric Sciences at the University of São Paulo (IAG-USP) has concentrated fully on its data management system. This report describes the efforts of the IAG-USP to set up a seismology data management system to facilitate local and international cooperation. © 2011 by the Istituto Nazionale di Geofisica e Vulcanologia. All rights reserved.
Resumo:
Several factors have contributed to the increase the world production of urban solid waste, resulting in difficulties to the correct management and the final environmentally appropriate disposal, in addition to causing serious socio-economic, environmental, and public health troubles. The soil and groundwater contamination by leachate in waste disposal sites is almost always present, leveraging the emergence and/or adaptation of methodologies for environmental assessment of these areas. The geophysical methods, especially the electrical resistivity method, are fast, reliable and low-cost alternative for this purpose. This paper reports the methodology adopted for the temporal monitoring of the plume of contamination of controlled landfill in the municipality of Rio Claro (SP). Electrical resistivity data were obtained in 1999 and 2008, by the resistivity method, using the techniques of vertical electrical sounding and electrical profile. In both years, similar tests were carried out in the same locations within the disposal area. The results indicated that the plume of contamination has resistivity values less than or equal to 50 ohm.m and moves guided by 2 flows: the main, to the southeast, and the secondary, to the west. Relatively to the first series of tests in 1999, the plume of contamination was higher and deeper in 2008, contrary to what was expected for a landfill deactivated for at least 10 years.
Resumo:
Mineral research works are fundamentals for recognition and incorporation of new reserves. This paper present an integrated analysis of geologic and metallogenetics data, with results gotten from the application of the Induced Polarization geophysical method, in an copper ore occurrence, inserted in Camaquã sedimentary basin, situated in northeast of Caçapava do Sul city (RS). In area ocurr arkosean arenites average coarse, the intensely silicified and recrystallized, pertaining to Passo da Promessa Formation. The presence of azurita and malachite in breakings and high porosity zones of the host rock characterizes the mineral occurrence in surface, located in the crossing two fault families. The inversion models indicate the predominance of high chargeability in vulcanics tuff, rock of high porosity in relation to the andesites and metaconglomerates gifts in the area. The strong structural control of the mineral occurrence associated the high chargeability in volcanic tuff is indications of the hydrothermal fluid access by means of faults, until rocks with great porosity, where it occurred disseminations of copper sulfides in depth and carbonates in surface.
Resumo:
The mineral exploration is a complex activity that should involve a combination of direct and indirect techniques of geological investigation. The growing demand for base metals in the national and international market provides the revaluation of mineral occurrences that can become deposits and mines. This paper presents the results of the electrical resistivity and induced polarization geophysical methods in azimuthal arrangement, applied in a mineral occurrence of disseminated copper sulfides, previously studied through trenches and core drilling, located in the Camaquã Sedimentary Basin, Rio Grande do Sul State, Brazil. The inversion models indicate the coincidence of high chargeability and low resistivity values. The integration of geophysical data permitted the elaboration of 3D attributes visualization models for the mineralization enclosed in volcanic tuffs. The integrated geophysical and geological analysis indicates the potential of a new mineralized area. © 2012 Sociedade Brasileira de Geofísica.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Pós-graduação em Geologia Regional - IGCE
Resumo:
Pós-graduação em Geologia Regional - IGCE
Resumo:
Pós-graduação em Geologia Regional - IGCE