257 resultados para Fractured implant


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to present the factors that influence planning for immediate loading of implants through a literature review for treatment success. Research was conducted in the PubMed database including the key words immediate implant loading, implant-supported prostheses, and implant planning for studies published from 2000 to 2011. Forty-eight articles were used in this review to describe the indications and counterindications, presurgical planning, and technologies available for planning of this treatment alternative.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of implant-supported prosthesis to replace missing teeth became a predictable treatment. Although high success rate has been reported, implant treatment is suitable to complications, failures, and limitations such as peri-implant bone loss after implant loading. Stress evaluation on the bone-abutment-implant interface has been carried out to develop new designs of prosthetic platform and to understand the stress distribution in this interface. Several types of prosthetic platforms are available such as external and internal hexagon, Morse cone connection, and the concept of platform switching. Therefore, this study aimed to critically describe the different options of prosthetic platforms in implant dentistry, by discussing their biomechanical concepts, clinical use, and advantages and disadvantages. It was observed that all types of prosthetic platforms provided high success rate of the implant treatment by following a strict criteria of indication and limitation. In conclusion, a reverse planning of implant treatment is strongly indicated to reduce implant overload, and the use of advanced surgical-prosthetic techniques is required to obtain a long-term success of oral rehabilitations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The aim of this study was to assess the influence of cusp inclination on stress distribution in implant-supported prostheses by 3D finite element method.Materials and Methods: Three-dimensional models were created to simulate a mandibular bone section with an implant (3.75 mm diameter x 10 mm length) and crown by means of a 3D scanner and 3D CAD software. A screw-retained single crown was simulated using three cusp inclinations (10 degrees, 20 degrees, 30 degrees). The 3D models (model 10d, model 20d, and model 30d) were transferred to the finite element program NeiNastran 9.0 to generate a mesh and perform the stress analysis. An oblique load of 200 N was applied on the internal vestibular face of the metal ceramic crown.Results: The results were visualized by means of von Mises stress maps. Maximum stress concentration was located at the point of application. The implant showed higher stress values in model 30d (160.68 MPa). Cortical bone showed higher stress values in model 10d (28.23 MPa).Conclusion: Stresses on the implant and implant/abutment interface increased with increasing cusp inclination, and stresses on the cortical bone decreased with increasing cusp inclination.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This report presents the use of a dental implant with an anti-rotational attachment for the retention of a thumb prosthesis. A retention system was manufactured with an attachment (UCLA) screwed into the implant with a two-bar system that was cast in metallic silver palladium. A substructure made from heat-cured acrylic resin was joined to the retention system by clips to join the thumb to the finger (bar clip) in the cast with implant rejoinder. The silicone material, Silastic-MDX 44210, was used to achieve function and aesthetics. Following osseointegration, no skin problems were observed. Whilst the implant-retained digital prosthesis presented some motor limitations, it allowed the patient to return to entertainment and achieve social conviviality.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose:The purpose of this study was to evaluate stress transfer patterns between implant-tooth-connected prostheses comparing rigid and semirigid connectors and internal and external hexagon implants.Materials and Methods:Two models were made of photoelastic resin PL-2, with an internal hexagon implant of 4.00 x 13 mm and another with an external hexagon implant of 4.00 x 13 mm. Three denture designs were fabricated for each implant model, incorporating one type of connection in each one to connect implants and teeth: 1) welded rigid connection; 2) semirigid connection; and 3) rigid connection with occlusal screw. The models were placed in the polariscope, and 100-N axial forces were applied on fixed points on the occlusal surface of the dentures.Results:There was a trend toward less intensity in the stresses on the semirigid connection and solid rigid connection in the model with the external hexagon; among the three types of connections in the model with the internal hexagon implant, the semirigid connection was the most unfavorable one; in the tooth-implant association, it is preferable to use the external hexagon implant.Conclusions:The internal hexagon implant establishes a greater depth of hexagon retention and an increase in the level of denture stability in comparison with the implant with the external hexagon. However, this greater stability of the internal hexagon generated greater stresses in the abutment structures. Therefore, when this association is necessary, it is preferable to use the external hexagon implant.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim: To describe the orthodontic, periodontal and prosthetic management of a case with a 3 mm root fracture below the crest of the alveolar bone.Methods: The root was extruded and periodontal surgery carried out to improve aesthetics and dental function.Conclusion: A multidisciplinary approach to the management of dental root fractures is necessary for successful treatment. (Aust Orthod J 2010; 26: 90-94)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to evaluate implants installed with compromised primary stability associated or not with polylactide and polyglycolide copolymer (PLA/PGA). Two 0.4-mm overdrilled defects (3 mm in diameter and 6 mm long) were produced in the right tibia of 25 rabbits. Half of the defects were left untreated, and the other half was filled with PLA/PGA. Implants of 2.6 mm in diameter and 6 mm long were placed into all defects. Animals were killed at 5, 15, 40, and 60 postoperative days, and biomechanical analysis (torque-reverse), histomorphometry, and immunohistochemistry (osteoprotegerin, receptor activator of NFJB ligand [RANKL], osteocalcin, and collagen-1 [ COL- I] staining) were performed. All the implants achieved osseointegration. There were no statistically significant differences in the torque-reverse and in linear contact extension between bone tissue and implant surface and no statistically significant difference in osteoprotegerin, RANKL, osteocalcin, and collagen-1 expression between the studied groups in all studied periods (P > 0.05). We can conclude that osseointegration can occur in compromised primary implant stability situations, and the addition of PLA/PGA did not improve the osseointegration process in this experimental model.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: This study sought to evaluate the effect of repeated implant drilling on the immediate bone-cell viability, and to evaluate drill wear by scanning electron microscopy.Materials and Methods: The tibiae of 10 rabbits were used, divided into 5 groups (G): G1 corresponded to new drills, and G2, G3, G4, and G5 corresponded to drills used 10, 20, 30, and 40 times, respectively. The animals received 10 sequential osteotomies in each tibia. The animals were euthanized immediately after the osteotomies by perfusion with 4% formaldehyde. Samples then underwent immunohistochemistry processing for ordinal qualitative analysis of osteoprotegerin (OPG), the RANK ligant (RANKL; a tumor-related necrosis factor receptor family), and osteocalcin protein immunolabels, as detected by the immunoperoxidase method and revealed with 3,3-diaminobenzidine. Drill wear and plastic deformation were analyzed by scanning electron microscopy (SEM).Results: The proteins were expressed in osteocytes of the superior bone cortical during the 40 drillings. However, in G4 and G5, a discrete increase in the expression of RANKL was observed, when compared with OPG; this increase was statistically significant in G5 (P = .016). The SEM analysis revealed major plastic deformation and drill wear in G4 and G5.Conclusion: Based on the present methodology, it may be concluded that cell viability is preserved if a less traumatic surgical protocol is used. However, the repeated use of drills alters the protein balance as of the thirtieth perforation. (C) 2008 American Association of Oral and Maxillofacial Surgeons.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to perform a photoelastic analysis of stress distribution on straight and angulated implants with different crowns (screwed and cemented). Three models were made of photoelastic resin PL-2: model 1: external hexagon implant 3.75 x 10.00 mm at 0 degrees; model 2: external hexagon implant 3.75 x 10.00 mm at 17 degrees; model 3: external hexagon implant 3.75 x 10.00 mm at 30 degrees. Axial and oblique (45 degrees) load (100 N) was applied with a universal testing machine. The photoelastic fringes on the models were recorded with a digital camera and visualized in a graphic software for qualitative analysis. The axial loading generated the same pattern of stress distribution. The highest stresses were concentrated between medium and apical thirds. The oblique loading generated a similar pattern of stress distribution in the models with similar implant angulation; the highest stress was located on the cervical region opposite to implant angulation and on the apical third. It was concluded that the higher the implant angulation, the higher the stress value, independent of crown type. The screwed prostheses exhibited the highest stress concentration. The oblique load generated higher stress value and concentration than the axial load.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article reports the 20-month clinical outcome of the use of 4 zygomatic implants with immediate occlusal loading and reverse planning for the retreatment of atrophic edentulous maxilla after failed rehabilitation with autogenous bone graft reconstruction and maxillary implants. The intraoral clinical examination revealed mispositioned and loosened implants underneath a maxillary complete denture. The panoramic radiograph showed 6 maxillary implants. One implant was displaced into the right maxillary sinus, and the implant anchored in the region of tooth 21 was fractured. The other implants presented peri-implant bone loss. The implants anchored in the regions of teeth 21 to 23 and 11 to 13 were first removed. After 2 months, the reverse planning started with placement of 4 zygomatic fixtures, removal of the implants migrated into the sinus cavity and anchored in the region of tooth 17, and installation of a fixed denture. After 20 months of follow-up, no painful symptoms, peri-implant inflammation or infection, implant instability, or bone resorption was observed. The outcomes of this case confirm that the zygoma can offer a predictable anchorage and support function for a fixed denture in severely resorbed maxillae.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The aim of this study was to evaluate by means of digital radiography the behavior of the alveolar bone crest in external hexagon implants following the use of 2 different types of abutments, one for conventional cemented prosthesis and one for modified cemented prosthesis.Methods: Ten external hexagon implants (platform 4.1) were placed in 5 patients. Initial instrumentation was carried out to obtain primary stability of the temporary prostheses under immediate loading. Each patient received both abutments for conventional and modified cemented prosthesis. Standardized digital periapical radiographies were performed at times T0 (immediately after implant placement) and T1 (4 months after implant placement). A straight line was initially established from the implant platform to the distal and mesial periimplantar marginal bone tissue (immediately in contact with the implant) and measured by digital radiography, using Sidexis version 2.3 (Sirona Dental Systems GmbH, Bensheim, Germany) software. The data were submitted to paired-samples t-test analysis.Results: There was no significant difference between the conventional and modified cemented prosthesis. In both cases, t-test results were within the null hypothesis level.Conclusion: The abutment for the modified cemented prosthesis resulted in no significant radiographic difference of alveolar bone crest height, when compared with the conventional cemented prostheses.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Computed tomographic scanning is a precise, noinvasive surveying technique that enables the professionals to improve the precision of implant placement by building a prototype that allows the confection of surgical guides. The authors present a clinical case of anterior tooth rehabilitation with frozen homogenous bone graft and immediately loaded titanium implant using computer-guided surgery. A multislice computed tomography was realized, and a prototype was built. All the procedures were previously realized in the prototype before started in the patient. This technique allows a better surgical planning, makes the procedures more accurate, and reduces surgery time.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Post-traumatic complications occasionally lead to tooth loss as well as the need for future implants. However, rehabilitation with endosseous osseointegrated implants does not protect the patient from the risk of suffering a new trauma. Implant fracture and the damage of the hexagon are post-traumatic complications that guide the clinician to preparing a more intricate treatment plan. The authors present a clinical case of a recurrent trauma of maxillary implant fracture. The treatment plan was to remove the implants followed by autogenous bone grafting to correct the defect. Two titanium implants were replaced, followed by connective tissue graft after allowing complete the healing process of the bone graft to occur. In the postoperative period of 6 months, satisfactory results have been shown as regards soft and hard tissues wound healing.