307 resultados para Fluvial Abrasion


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To determine the influence of different dentin treatments on the microtensile bond strengths of adhesive resins to dentin. Methods: Fifteen human molars were ground to 600-grit to obtain flat root-dentin surfaces. Five different dentin treatments were evaluated: Group 1 - 10% phosphoric acid for 30 seconds; Group 2 - 37% phosphoric acid for 15 seconds; Group 3 - air-abrasion for 10 seconds followed by 10% phosphoric acid for 30 seconds; Group 4 - air-abasion for 10 seconds followed by 37% phosphoric acid for 15 seconds. The dental adhesive (OptiBond Solo Plus) was applied according to manufacturer's instructions and followed by composite (Z100) application to provide sufficient bulk for microtensile bond testing. All samples were placed in distilled water for 24 hours at 37degreesC, thermocycled for 500 cycles in distilled water at 10degreesC and 50degreesC, and serially sliced perpendicular to the adhesive surface and subjected to tensile forces (0.5 mm/minute). Additional samples were prepared for SEM to observe the adhesive interface. Results: Group 2 exhibited significantly (P< 0.05) lower bond strength values than all other treatments. The bond strengths of the different conditions were (in MPa): Group 1: 43.0 +/- 16.1; Group 2: 29.2 +/- 8.3; Group 3: 48.1 +/- 14.2; Group 4: 41.0 +/- 9.3. The dentin treated with phosphoric acid 37% for 15 seconds showed the lowest values of microtensile bond strength. The results obtained with Groups 1, 3 and 4 were statistically similar.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: the aim of this in vitro study was to assess the effect of tip diameter, nozzle distance, and application time of an air-abrasion system for cavity preparation on the enamel of primary teeth. Method and materials: Forty exfoliated primary teeth were air abraded with a microabrasion machine used with a handpiece with an 80-degree-angle nozzle, 50-mum abrasive particle size, and 80-psi air pressure. The effects of 0.38- or 0.48-mm inner tip diameter, 2- or 5-mm distance from tip to tooth surface, and 15 or 30 seconds of application time on cutting efficiency were evaluated. Cutting width and depth were analyzed and measured from scanning electron micrographs. Results: Statistical analysis revealed that the width of the cuts was significantly greater when the tip distance was increased. Significantly deeper cavities were produced by a tip with a 0.48-mm inner diameter. The application time did not influence the cuts. Conclusion: the cutting patterns found in this study suggest that precise removal of enamel in primary teeth is best accomplished when a tip with a 0.38-mm inner diameter is used at a 2-mm distance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This in situ/ex vivo study assessed the effect of fluoride dentifrice on eroded enamel subjected to brushing abrasion. In a crossover study performed in 2 phases, 10 volunteers wore acrylic palatal appliances, each containing 3 human enamel blocks. Dentifrice was used to brush the volunteers' teeth and the specimens subjected to abrasion. In phases A and B the dentifrices used had the same formulation, except for the absence or presence of fluoride, respectively. The blocks were subjected to erosion by immersion of the appliances in a cola drink for 5 min, 4 times a day. Then the blocks were brushed, and the appliance was replaced into the mouth. Enamel alterations were determined using profilometry and percentage change in surface microhardness (%SMHC) tests. The data were tested using the paired t test. The mean wear values (+/- SD, mu m) were: group A 6.84 +/- 1.72 and group B 5.38 +/- 1.21 (p = 0.04). The mean %SMHC values (+/- SD) were: group A 54.6 +/- 16.2 and group B 45.7 +/- 6.8 (p = 0.04). Fluoride dentifrice had a protective effect on eroded enamel subjected to brushing abrasion. Copyright (c) 2007 S. Karger AG, Basel.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose : the aim of this study was to evaluate the effect of nozzle angle and tip diameter on the cutting efficiency of an air abrasion system. Materials and Methods: Thirty-six extracted human third molars were air-abraded with the PrepStar microabrasion machine using a handpiece with either 80degrees or 45degrees nozzle angles with 0.38 or 0.48 nun tip orifice diameters. The following parameters were held constant: abrasive particle size (27 mum), air pressure (80 psi), distance (2 mm.) and duration (15 seconds). The cutting efficiency was compared using enamel, dentin and cementum substrates. Width and depth of the cutting patterns were analyzed and measured using scanning electron micrographs. Results: Statistical analysis using three-way ANOVA and Duncan's Multiple Range test revealed that the width of the cuts was significantly greater when the cavities were prepared using the 45degrees nozzle angle. Significantly deeper cavities were produced with the 80degrees nozzle angle. The tip orifice of the nozzle influenced the cutting efficiency in softer substrates, dentin and cementum. Precise removal of hard tissue is best accomplished using the 80degrees angle nozzle tips for all types of tooth surfaces, enamel, dentin and cementum.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: This in situ/ex vivo study evaluated whether a rinse with an iron solution could reduce wear and the percentage of microhardness change of human enamel and dentine submitted to erosion followed by brushing after 1 or 30 min.Design: During 2 experimental 5-day crossover phases (wash-out period of 10 days), 10 volunteers wore intraoral palatal devices, with 12 specimens (6 of enamel and 6 of dentine) arranged in 3 horizontal rows (4 specimens each). In one phase, the volunteers immersed the device for 5 min in 150 mL of cola drink, 4 times a day. Immediately after immersion, no treatment was performed in one row. The other row was brushed after 1 min using a fluoride dentifrice and the device was replaced into mouth. After 30 min, the remaining row was brushed. In the other phase, the procedures were repeated, but after immersion the volunteers rinsed for 1 min with 10 mL of a 10 mM ferrous sulphate solution. Changes in surface microhardness (%SMH) and wear (profilometry) of enamel and dentine were measured. Data were tested using ANOVA and Tukey's tests (p < 0.05).Results: the enamel presented more wear than dentine, under all experimental conditions. The iron solution caused a significant reduction on the %SMH in enamel, and a significant reduction on the wear in dentine, regardless the other conditions.Conclusions: Rinsing with an iron solution after an erosive attack, followed or not by an abrasive episode, may be a viable alternative to reduce the loss of dental structure. (c) 2006 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study assessed cavity preparations produced with different air abrasion tip parameters. Twelve test groups of extracted teeth were prepared to evaluate the parameters of 80 degrees or 45 degrees nozzle angles and 0.38 or 0.48 mm inner tip diameters. All other factors were held constant. A device was made to hold the specimen and air abrasion handpiece that standardized the distance and position relative to the tooth and time of application. The cavities were evaluated by assessing the rounding of the cavosurface margins and cavity floor. Measurements of cavosurface angles and the angle of concavity were made at the deepest portion of the abraded surface using scanning electron micrographs. The cavosurface angles were compared using paired t-test, and the effects of the tip design parameters were analyzed by ANOVA and Duncan's Multiple Range test. From the cavity patterns found in this study, the authors suggest that 80 degrees angle tips are more appropriate than 45 degrees angle tips for making narrow, deep cuts for preventive resin restorations. Conversely, when shallow preparations are needed, as in the case of Class V cavity preparations, cutting patterns of 45 degrees angle tips are more suitable.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this study is the geometric characterization of a fluvial system, exemplified by the Itaquaquecetuba Formation. The studied area is a quarry located in Itaquaquecetuba, distant 35 km from the city of São Paulo, which is inserted in the context of São Paulo Basin. Fluvial systems are important hydrocarbon reservoirs, and this study may contribute with an analogue for ancient reservoirs. It was elaborated ten facies logs along a distance of 200 m (log spacing of 20 m), with a vertical column (thickness) of 40 m for each log. Eight facies cycles, and its lateral chrono-correlation allowed to map the potential reservoir and non-reservoir facies within each cycle. Regarding the depositional model for the studied section, it is assumed an alluvial fan system composed of meandering and ribbon-type fluvial channels.