40 resultados para Film and HIstory


Relevância:

90.00% 90.00%

Publicador:

Resumo:

We investigated the alignment induced on a nematic liquid crystal (LC) by a photo-aligned polymer film with azo-dye side groups. The orientation of the LC molecules can be manipulated in a reversible manner by irradiating the film with polarized light. We analyzed the competition between the orientation induced by the main chain, through rubbing of the film and that induced by the photo-aligned polymer. Anchoring strength for the different processing conditions are reported. The changes in film morphology caused by rubbing or photo-alignment could be captured by atomic force microscopy. The reversibility of the photo-induced alignment and the competition between the two anchoring mechanisms may allow recording and erasing of information in a LC display.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

We have studied the effects of niobium beam filtration on absorbed doses, on image density and contrast, and on photon spectra with conventional and high-frequency dental x-ray generators. Added niobium reduced entry and superficial absorbed doses in periapical radiography by 9% to 40% with film and digital image receptors, decreased the radiation necessary to produce a given image density on E-speed film and reduced image contrast on D- and E-speed films. As shown by increased half-value layers for aluminum, titanium, and copper and by pulse-height analyses of beam spectra, niobium increased average beam energy by 6% to 19%. Despite the benefits of adding niobium on patient dose reduction and on narrowing the beams' energy spectra, the beam can be overhardened. Adding niobium, therefore, strikes the best balance between radiation dose reduction and beam attenuation, with its risks of increased exposure times, motion blur, and diminished image contrast, when it is used at modest thicknesses (30 μm) and at lower kVp (70) settings. © 1995 Mosby-Year Book, Inc.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The respiratory and storage behavior of fresh cut 'Tommy Atkins' mango, naturally ripened (NR) or with use of ethylene (RE), were studied. Fruits were selected, washed and disinfected (200 mgCl.L-1) and stored for 12 hours at 10°C. After this period, they were processed under hygienic conditions at 10°C, packaged in polyethylene terephthalate (PET) trays or in styrofoam trays wrapped with stretchable polyvinyl chloride (PVC) film and stored for up to 15 days at 3°C. The products were evaluated regarding the evolution of internal atmosphere in the packing (O2 and CO 2), development of weight, appearance, shelf life and consumer acceptability. The respiratory rate was measured before and after processing every two hours. The yield of 'Tommy Atkins' mango to produce fresh cut product was 48.09±0.95%. Increase of the respiration rate of both mango samples was verified one hour after the preparation (NR = 17.75 mL CO 2.kg-1.h-1; RE = 28.29 mL CO 2.kg-1.h-1), followed by stabilization at 3.76 and 8.07 mL CO2/kg.h, respectively. The percentage of O2 in packages was stable in all treatments, 15-20% in PVC trays, 18-20% in PET tray. The percentage of CO2 was steady around 1.5-2.5%. The products lost fresh mass during the storage, from 0.06% to 0.30% for PET trays and from 0.15% to 1.61% for trays covered with PVC. The appearance was considered appropriate for commercialization until the 13th day, whereas product from mangoes ripened with application of ethylene was for 11 days, presenting browning in the external surface. The naturally ripened mango presented the best flavor and consumer preference in relation to the mango ripened with application of ethylene for 11 days of storage. The control of hygienic conditions during the production and storage was good and with safety for until 10 days.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The study was performed in a greenhouse with the aim of evaluating the production of butterhead lettuce cultivars with and without plastic film mulch in the summer. The cultivars studied were 'Elisa', 'Lídia', 'Herman' and 'Luísa'. The experimental design was a split plot, in which the main plot was plastic film mulch (with or without black polyethylene film) and the subplots were the cultivars, with three repetitions. The seedlings were grown in Styrofoam trays of 288 cells and transplanted 25 days after seeding in a space of 25 × 25 cm. Harvests were carried out 45 days after transplanting and the following variables were determined: fresh and dry weights of the aerial part, number of leaves per plant, plant height and the longitudinal and transverse diameters of the plant. Significant differences were found only among the cultivars for the characteristics studied, with no cover × cultivar interaction. Fresh weight of the aerial part of 'Lídia' (270.9 g) was greater than that of 'Herman' (142.5 g), but did not differ from those of 'Luísa' (229.8 g) or 'Elisa' (204.8). The dry weight of the aerial part of 'Lídia' (12.4 g) differed statistically only with respect to that of 'Herman' (7.9 g). The cultivars 'Luísa' and 'Elisa' had an aerial part dry weight of 11.4 and 11.2 g, respectively. The number of leaves per plant of the cultivars 'Luísa' (45.1) and 'Elisa' (43.0) was higher than for 'Herman' (24.05), but did not differ from that of the cultivar 'Lídia' (39.5). The mean transverse and longitudinal diameters, as well as the mean height of the plants, showed that 'Lídia', 'Elisa' and 'Luísa' had the greatest values. The cultivars 'Lídia', 'Elisa' and 'Luísa' were the most productive and plastic film mulch had no effect on lettuce production under protected cultivation.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The purpose of this study was to evaluate the radiopacity of root canal sealers containing calcium hydroxide and MTA (Acroseal, Sealer 26, Sealapex, Endo CPM Sealer, Epiphany and Intrafill). Five disc-shaped specimens (10 x 1 mm) were fabricated from each material, according to the ISO 6876/2001 standard. After setting of the materials, radiographs were taken using occlusal film and a graduated aluminum stepwedge varying from 2 to 16 mm in thickness. The dental X-ray unit (GE1000) was set at 50 kVp, 10 mA, 18 pulses/s and distance of 33.5 cm. The radiographs were digitized and the radiopacity compared to that of the aluminum stepwedge using VIXWIN-2000 software (Gendex). The data (mmAl) were analyzed statistically by ANOVA and Tukey's test at the 5% significance level. Epiphany and Intrafill presented the highest radiopacity values (8.3 mmAl and 7.5 mmAl respectively, p < 0.05) followed by Sealer 26 (6.3 mmAl), Sealapex (6.1 mmAl) and Endo CPM Sealer (6 mmAl). Acroseal was the least radiopaque material (4 mmAl, p < 0.05). In conclusion, the calcium hydroxide- and MTA-containing root canal sealers had different radiopacities. However, all materials presented radiopacity values above the minimum recommended by the ISO standard. © 2009 Sociedade Brasileira de Pesquisa Odontológica.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

A study on the electrochemical behavior of histamine species in aqueous medium is described. A glassy carbon electrode chemically modified with copper (II) hexacyanoferrate (CuHCFe) film and covered with Nafion® film was employed. The interaction between the analyte and the CuHCFe film can be demonstrated by a decrease in both the cathodic and anodic peak currents at 0.68V (vs. Ag/AgCl), attributed to the film and the appearance of new peak current at 0.47V. Cyclic voltammetric parameters obtained for histamine indicate the formation of stable complex between histamine adsorbed at the electrode surface. The dependence of peak currents on the concentration of the analyte is not linear in the employed work range, indicating the presence of a coupled chemical reaction in the electrodic process. © 2010 by ESG.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Trying to reduce particle contamination in lubrication systems, industries of the whole world spend millions of dollars each year on the improvement of filtration technology. In this context, by controlling fluid cleanliness, some companies are able to reduce failures rates up to 85 percent. However, in some industries and environments, water is a contaminant more frequently encountered than solid particles, and it is often seen as the primary cause of component failure. Only one percent of water in oil is enough to reduce life expectancy of a journal bearing by 80 percent. For rolling bearing elements, the situation is worse because water destroys the oil film and, under the extreme temperatures and pressures generated in the load zone of a rolling bearing element, free and emulsified water can result in instantaneous flash-vaporization giving origin to erosive wear. This work studies the effect of water as lubricant contaminant in ball bearings, which simulates a situation that could actually occur in real systems. In a designed bench test, three basic lubricants of different viscosities were contaminated with different contents of water. The results regarding oil and vibration analysis are presented for different bearing speeds.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

It is shown that highly conducting films of polyaniline protonated with di-esters of sulfosuccinic and sulfophthalic acids which contain alkyl- or alkoxy-type substituents exhibit highly anisotropic structural, electrical and magnetic properties. The layered-like structure of these films can be described as consisting of polyaniline chains which are mainly oriented parallel to the plane of the film and form regular out-of-plane stacks. These stacks are separated by bilayers of the dopant anions. Accordingly, the main anisotropy observed for solution cast films implies in-plane and out-of-plane measurements. An electrical anisotropy of about 80 is found for the in-plane and out-of-plane electronic conductivities at 5 K. The temperature dependences of the in-plane and out-of-plane conductivities are qualitatively similar and have been fitted as a series combination of variable-range-hopping-type and power law contributions. A maximum is observed in the temperature dependence of the electrical anisotropy at low temperature. The films also show a clear anisotropy of magnetization whose temperature and field characteristics depend on the chemical structure of the dopant anion. © 2013 Elsevier B.V.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Purpose: The purpose of this study was to evaluate the effect of diamond-like carbon thin films doped and undoped with silver nanoparticles coating poly(methyl methacrylate) (PMMA) on Candida albicans biofilm formation. The control of biofilm formation is important to prevent oral diseases in denture users. Materials and Methods: Forty-five PMMA disks were obtained, finished, cleaned in an ultrasonic bath, and divided into three groups: Gc, no surface coating (control group); Gdlc, coated with diamond-like carbon film; and Gag, coated with diamond-like carbon film doped with silver nanoparticles. The films were deposited using a reactive magnetron sputtering system (physical vapor deposition process). The specimens were characterized by optical profilometry, atomic force microscopy, and Rutherford backscattering spectroscopy analyses that determined differences in chemical composition and morphological structure. Following sterilization of the specimens by γ-ray irradiation, C. albicans (ATCC 18804) biofilms were formed by immersion in 2 ml of Sabouraud dextrose broth inoculated with a standardized fungal suspension. After 24 hours, the number of colony forming units (cfu) per specimen was counted. Data concerning biofilm formation were analyzed using ANOVA and the Tukey test (p < 0.05). Results: C. albicans biofilm formation was significantly influenced by the films (p < 0.00001), reducing the number of cfu, while not affecting the roughness parameters (p > 0.05). The Tukey test showed no significant difference between Gdlc and Gag. Films deposited were extremely thin (∼50 nm). The silver particles presented a diameter between 60 and 120 nm and regular distribution throughout the film surface (to Gag). Conclusion: Diamond-like carbon films, doped or undoped with silver nanoparticles, coating the base of PMMA-based dentures could be an alternative procedure for preventing candidosis in denture users. © 2013 by the American College of Prosthodontists.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

In this work we described for the first time the construction of a 25 μL electrochemical cell from low temperature co-fired ceramic (LTCC) material and carbon screen-printed electrode applicable in portable devices. Firstly, a carbon screen-printed electrode was prepared and characterized by cyclic voltammetry and scanning electron microscopy. Afterwards carbon polymeric film and metal pastes were dropped into the LTCC cell cavities in order to determine the device electrodes, and this arrangement was also electrochemically characterized. The great advantage of this promising device is the simple construction method and its widespread applicability in reusable portable devices. © 2013 The Royal Society of Chemistry.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This study evaluated the influence of deposition parameters for Si-based thin films using magnetron sputtering for coating zirconia and subsequent adhesion of resin cement. Zirconia ceramic blocks were randomly divided into 8 groups and specimens were either ground finished and polished or conditioned using air-abrasion with alumina particles coated with silica. In the remaining groups, the polished specimens were coated with Si-based film coating with argon/oxygen magnetron discharge at 8:1 or 20:1 flux. In one group, Si-based film coating was performed on air-abraded surfaces. After application of bonding agent, resin cement was bonded. Profilometry, goniometry, Energy Dispersive X-ray Spectroscopy and Rutherford Backscattering Spectroscopy analysis were performed on the conditioned zirconia surfaces. Adhesion of resin cement to zirconia was tested using shear bond test and debonded surfaces were examined using Scanning Electron Microscopy. Si-based film coating applied on air-abraded rough zirconia surfaces increased the adhesion of the resin cement (22.78 ± 5.2 MPa) compared to those of other methods (0-14.62 MPa) (p = 0.05). Mixed type of failures were more frequent in Si film coated groups on either polished or air-abraded groups. Si-based thin films increased wettability compared to the control group but did not change the roughness, considering the parameters evaluated. Deposition parameters of Si-based thin film and after application of air-abrasion influenced the initial adhesion of resin cement to zirconia. © 2013 Elsevier B.V. All rights reserved.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Pós-graduação em Letras - IBILCE