181 resultados para Facial fractures


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A 15-month-old DSH cat was presented with facial deformity secondary to multiple oral and maxillofacial fractures after being struck by an automobile. Multiple wires and dental acrylics were used for fracture repair.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Pythiosis in horses is a proliferative and ulcerative disease that primarily affects the skin and subcutaneous tissue of limbs, thoracic-abdominal region and head. This disease sometimes can also affect limb bones or cause tumoral masses in abdomen. Usually, the cutaneous cases are confused with habronemiasis. The disease is more common in marshy areas, places with formation of slow drainage ponds and aquatic vegetation under high temperatures. The aim of this study was to describe the development of facial lesions in a horse caused by pythiosis in Cuiaba, Mato Grosso, and, additionally to discuss relevant issues regarding the diagnosis, clinical course and response to immunotherapy treatment.Case: One five years old mare of unknown breed, created in property located in the Cerrado region, had a wound on its face difficult to be healed and non-responsive to several treatments based on ivermectin and organophosphate administrated by either topical or systemic via. The animal was assisted on the farm of origin by the veterinary team of the Clinical Medicine sector, of the Veterinary Hospital, Universidade Federal de Mato Grosso (HOVET-UFMT). on the occasion of the visit, which occurred 60 days after onset of signs, the animal showed a circular single large lesion, ulcerative with serous discharge on the right part of its face, between the eyes and nostrils. There were some necrotic foci with sinus, from which kunkers were extracted; a condition compatible with pythiosis. The diagnosis was confirmed by histology, ELISA and PCR.Discussion: Assuming pythiosis from data obtained from the survey and profile of the lesion (secretory aspect, emaciation and presence of sinus and kunkers), immunotherapy treatment was immediately applied. The advanced clinical aspects and the fact that early diagnosis and treatment are essentials to satisfactory therapeutic response were also taken into consideration for starting the treatment. The remission of signs was achieved after five subcutaneous applications with 14 days between each application. From the second application, it was observed clinical improvement and after 60 days of treatment there was almost complete remission of signs. The signs for a satisfactory response in the injury site followed the order of decreasing secretory aspect, decreasing borders, decrease the itching and bringing the edges together with the formation of a thin layer of crust on the surface. Pythiosis cases with lesions on the face and lower abdomen are commonly confused with habronemiasis by macroscopic and widespread similarity between technicians and attendants, and essential support to the diagnosis through laboratory tests, which in turn are still underutilized. In this case, the authors demonstrated the therapeutic efficacy of immunotherapy as an advantage, considering the possibility of applying it in cases of lesions in areas of difficult surgical access, treatment conditions in the field, with low cost and ease of application. Further studies approaching this alternative therapy are necessary, since side effects have been observed in some cases.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to evaluate the efficiency of the Pro-Fono Facial Exerciser (Pro-Fono Productos Especializaclos para Fonoaudiologia Ltda.., Barueri/SP, Brazil) to decrease bruxism, as well as the correlation between the masseter and the buccinator muscles using electromyography (EMG). In this study, 39 individuals ranging from 23 to 48 years of age were selected from a dental school and then underwent surface EMG at three different periods of time: 0, 10, and 70 days. They were divided into a normal control group, a bruxer control group (without device), and an experimental bruxer group who used the device. The bruxer group showed a greater masseter EMG amplitude when compared to the normal group, while the experimental group had deceased activity with a reduction in symptoms. The buccinator EMG spectral analysis of the experimental bruxist group showed asynchronous contractions of the masseter muscle (during jaw opening) after using the Pr6-Fono Facial Exerciser. The normal group also showed asynchronous contractions. Upon correlation of the data between these muscles, the inference is that there is a reduction in bruxism when activating the buccinator muscle.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: Pressure ulcer (PU) is a frequent complication of hip fracture. Studies were carried out to identify the risk factors of PU development after hip fractures. The objective of the study was to determine the role of anthropometric measurements and handgrip strength as predictors of PUs in patients with hip fractures during their hospital stay and 30 d after discharge, which has not yet been established.Methods: Ninety-two consecutive patients with hip fractures who were older than 65 y old and admitted to an orthopedic unit were prospectively evaluated. Within the first 72 h of admission, each patient's characteristics were recorded, anthropometric measurements were taken (circumferences of the arm, waist, thigh, calf, triceps, and biceps and subscapular and suprailiac skinfolds), handgrip strength was measured, and blood samples were collected. PU evaluations were performed during the hospital stay and 30 d after hospital discharge.Results: Three patients were excluded because of PUs before hospitalization. Eighty-nine patients (average age 80.6 +/- 7.5 y) were studied; 70.8% were women, and 49.4% developed PUs during their hospital stay. In a univariate analysis, length of hospital stay (P = 0.001) and handgrip strength (P = 0.02), but not body circumferences and skinfolds, were associated with PUs during a hospital stay. Only handgrip strength (P = 0.007) was associated with PUs 30 d after hospital discharge. In a multivariate analysis, only handgrip strength was found to predict PU development at these points.Conclusion: Handgrip strength was found to predict PU development in patients with hip fractures during their hospital stay and 30 d after discharge. (C) 2012 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Este estudo apresenta documentos de paralisia facial periférica nas artes plásticas no Egito antigo, Grécia e Roma, Idade Média, Renascimento e também dos últimos 4 séculos. Pensamos que a história da paralisia facial periférica acompanha a história da própria espécie humana. São apresentadas as contribuições de Avicenna e Nicolaus Friedreich, e são mostradas controvérsias sobre a descrição original de Charles Bell.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The hypothyroidism is the most commonly endocrinopathy in dogs, that occurs preferentially in middle-aged pure breed. The clinical signs associated with hypothyroidism are variable, many times non-specific, including metabolical, dermatological or cardiovascular. The main laboratorial findings are non-regenerative anemia and hypercholesterolemia. Hyponatremia, increase on alanine transferase and alkaline phosphatase activity also can be observed in a lower frequency. There are some reports of peripheral neuropathies caused by hypothyroidism, but the pathophysiology of this process is still unknown. There are specific diagnostic tests that can be used to help diagnose hypothyroidism, and those should be aligned together with the animal's clinical symptoms. The thyroxine stimulating hormone, and free and total thyroxine concentrations are the most used tests. A Pit Bull dog, female, over weighted, was treated presenting left facial paralysis. Thyroid function tests confirmed hypothyroidism. The animal was treated with hormonal replacement and there was improvement in clinical signs in 40 days, confirming that hypothyroidism was facial paralysis' cause.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Ramsay Hunt syndrome is a rare disease caused by an infection of the geniculate ganglion by the varicella-zoster virus. The main clinical features of the syndrome are as follows: Bell palsy unilateral or bilateral, vesicular eruptions on the ears, ear pain, dizziness, preauricular swelling, tingling, tearing, loss of taste sensation, and nystagmus. We describe a 23-year-old white woman, who presented with facial paralysis on the left side of the face, pain, fever, ear pain, and swelling in the neck and auricular region on the left side. She received appropriate treatment with acyclovir, vitamin B complex, and CMP nucleus. After 30 days after presentation, the patient did not show any signs or symptoms of the syndrome. At follow-up at 1 year, she showed no relapse of the syndrome.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to assess the behavior and stress distribution of 3 retention systems associated with implant for facial prosthesis by using the photoelasticity method. A photoelastic model was made from the replica of the orbital region on the left side of a dry skull with two 4-mm implants fixed in the superior orbital region. Three facial prosthetic retention systems were made for this study: O'ring, bar-clip, and magnets. The set (model/retention systems/prosthesis) was placed in a polariscope, and then traction began to be applied to the retention systems. The limit values for removal of the retention system were obtained by tests performed in an EMIC Universal test machine. The results were obtained by observation during the experiments and by photographic record of the stress behavior in the photoelastic model, resulting from the traction of the retention systems. In the magnet system, a lowest formation of fringes was verified both around and between the implants; in the O'ring system, the formation of photoelastic fringes was noted between the implants in the apical region; and in the bar-clip system, there was a greater concentration of colored fringes in the regions between the implants and cervical area. Based on the results obtained, it was concluded that the retention systems produced different stress distribution characteristics that, in general, were concentrated in the area around the implants, and the highest concentration of fringes, in increasing order, occurred ill the retention systems of the magnets, O'ring, and bar-clip.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Traumatic tooth injuries involve function and aesthetics and cause damage that range from minimal enamel loss to complex fractures involving the pulp tissue and even loss of the tooth crown. Technical knowledge and clinical experience are essential to establish an accurate diagnosis and provide a rational treatment. The purpose of this study was to evaluate the knowledge of Restorative Dentistry specialists about the management of crown and crown-root fractures based on treatment plans proposed by these professionals for these cases. A descriptive questionnaire was mailed to 245 Restorative Dentistry specialists with questions referring to their professional profile and the treatment plans they would propose for the management of crown and crow-root fractures resulting from dental trauma. One hundred and fifty-four questionnaires were returned properly filled. The data were subjected to descriptive statistics and the chi-square test was used to determine the frequency and the level of the significance among the variables. The analysis of data showed that in spite of having a specialist title, all interviewees had great difficulty in planning the treatments. As much as 42.8% of the participants were unable to treat all types of dental trauma. Complicated and uncomplicated crown-root fractures posed the greatest difficulties for the dentists to establish adequate treatment plans because these fractures require multidisciplinary knowledge and approach for a correct case planning and prognosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This in vitro study evaluated the influence of the type of miniplate and the number of screws installed in the proximal and distal segments on the stability and resistance of Champy's osteosynthesis in mandibular angle fractures. Sixty polyurethane hemimandibles with bone-like consistency were randomly assigned to four groups (n = 15) and sectioned in the mandibular angle region to simulate fracture. The bone segments were fixed by different osteosynthesis methods using 2.0 mm miniplates and 2.0 mm x 6 mm rnonocortical screws. In groups 1 and 2, two conventional (G1) or locking (G2) screws were installed in each bone segment using a conventional (G1) or a locking (02) straight miniplate; in groups 3 and 4, three conventional (03) or locking (04) screws were installed in the proximal segment and four conventional (G3) or locking (04) screws were installed in the distal segment using a conventional (G3) or a locking (G4) seven-hole straight miniplate. The hemimandibles were loaded in compressive strength until a 4 mm displacement occurred between the segments, vertically or horizontally. Locking plate/screw systems provided significantly greater resistance to displacement than conventional ones (p < .01). Locking miniplates offered more resistance than conventional miniplates. Long locking miniplates provided greater stability than short ones.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The matching of the aesthetic, functional, and psychosocial results of a facial deformity may produce devastating effects in its carriers, especially if the lesion is extensive or the treatment is aggressive. Because of this, the objective of the present article was to evaluate patient's satisfaction rating after surgical facial reconstruction or rehabilitation with oral and maxillofacial prosthesis, by means of reviewing the literature.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The failure of facial prostheses is caused by limitations in the properties of existing materials, especially the biocompatibility. This study aimed to evaluate the biocompatibility of maxillofacial silicones in subcutaneous tissue of rats. Thirty Wistar rats received subcutaneous implants of 3 maxillofacial silicone elastomers (LIM 6050, MDX 4-4210, and industrial Silastic 732 RTV). A histomorphometric evaluation was conducted to analyze the biocompatibility of the implants. Eight areas of 60.11 mm(2) from the surgical pieces were analyzed. Mesenchymal cells, eosinophils, and foreign-body giant cells were counted. Data were submitted to analysis of variance and Tukey test. Initially, all implanted materials exhibited an acceptable tissue inflammatory response, with tissue reactions varying from light to moderate. Afterward, a fibrous capsule around the silicone was observed. The silicones used in the current study presented biocompatibility and can be used for implantation in both medical and dental areas. Their prosthetic indication is conditioned to their physical properties. Solid silicone is easier to adapt and does not suffer apparent modifications inside the tissues.