234 resultados para Electromyography.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Despite its high incidence, patellofemoral pain etiology remains unclear. No prior study has compared surface electromyography frequency domain parameters and surface electromyography time domain variables, which have been used as a classic analysis of patellofemoral pain. Thirty one women with patellofemoral pain and twenty eight pain-free women were recruited. Each participant was asked to descend a seven step staircase and data from five successful trials were collected. During the task, the vastus medialis and vastus lateralis muscle activities were monitored by surface electromyography. The data were processed and analyzed in four variables of the frequency domain (median frequency, low, medium and high frequency bands) and three time domain variables (Automatic, Cross-correlation and Visual Onset between the vastus medialis and vastus lateralis muscles). Reliability, Receiver Operating Characteristic curves and regression models were performed. The medium frequency band was the most reliable variable and different between the groups for both muscles, also demonstrated the best values of sensitivity and sensibility, 72% and 69% for the vastus medialis and 68% and 62% for the vastus lateralis, respectively. The frequency variables predicted the pain of individuals with patellofemoral pain, 26% for the vastus medialis and 20% for the vastus lateralis, being better than the time variables, which achieved only 7%. The frequency domain parameters presented greater reliability, diagnostic accuracy and capacity to predict pain than the time domain variables during stair descent and might be a useful tool to diagnose individuals with patellofemoral pain.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Embora a análise no domínio da freqüência do sinal eletromiográfico (EMG) seja empregada na caracterização do processo de fadiga muscular localizada, sua aplicação, especificamente a da freqüência mediana (Fmed), é pouco explorada no âmbito esportivo. O objetivo do presente estudo foi verificar a viabilidade da aplicação do sinal EMG, através de sua análise no domínio da freqüência, como parâmetro para determinação e diferenciação no comportamento da fadiga muscular localizada. Dois grupos de sujeitos, um caracterizado como atletas (n =12) e outro como sedentários (n =12), foram submetidos a análises baseadas em procedimentos executados em três diferentes situações experimentais, todos envolvendo a modalidade de exercício isométrico: i) teste máximo para determinação da contração isométrica voluntária máxima (CIVM); ii) teste de fadiga, sustentado por 35 seg. a 80% da CIVM; iii) teste de recuperação, sustentado por 10 seg. a 80% da CIVM; neste ultimo foi monitorado o comportamento da Fmed nos três primeiros (Fmedi) e três últimos segundos (Fmedf) do sinal EMG no músculo tibial anterior durante o teste de fadiga. Durante os 10 segundos do teste de recuperação foi calculada a Fmed referente a todo o período (Fmedr). parâmetro utilizado no cálculo do índice de recuperação muscular (IRM). Os resultados apontam que a Fmedf apresentou valor menor em relação à Fmedi em ambos os grupos (p < 0,05). Quando comparado com o grupo de sedentários, o grupo de atletas apresentou valores maiores de Fmedi e Fmedf (p < 0,05). O valor médio e desvio-padrão do IRM para o grupo de atletas foram de 62,1% ± 28,7 e, para o grupo de sedentários, de 55,2% ± 27,8 (p > 0,05). Dessa forma, os resultados apresentados neste estudo permitem inferir a viabilidade na aplicação de parâmetros no domínio da freqüência do sinal EMG para a determinação e diferenciação do comportamento da fadiga muscular localizada.
Resumo:
The aim of this study was to analyze the reproducibility of the electromyography signal's parameters (EMG) in the frequency domain used in the characterization of localized muscle fatigue. Fifteen male subjects underwent a fatigue test based on isometric knee extension, being held at three different times at intervals of seven days. To assess the reproducibility of data between the tests we calculated the correlation coefficient (ICC) for the median frequency (MF) in total exercise time (MFT), MF obtained for every 10% of exercise time (MF10%) and the powers of the frequency bands obtained by dividing the power spectrum at windows of 20 Hz. The results showed: (1) excellent reproducibility for MFT, (2) good reproducibility for MF10%, and (3) greater variation in the signal EMG bands from 20 to 120 Hz, especially at the bands of 20-40 Hz and 40-60 Hz, which showed greater sensitivity to the process of muscle fatigue. We conclude that the MF is a variable that shows good reproducibility and that the fragmented analysis of the power spectrum, by means of frequency bands, showed that significant variations occur in the EMG signal during the installation of the fatigue process, having potential to become a new method for the characterization of localized muscle fatigue.
Resumo:
The aim of this study was to evaluate the efficiency of the Pro-Fono Facial Exerciser (Pro-Fono Productos Especializaclos para Fonoaudiologia Ltda.., Barueri/SP, Brazil) to decrease bruxism, as well as the correlation between the masseter and the buccinator muscles using electromyography (EMG). In this study, 39 individuals ranging from 23 to 48 years of age were selected from a dental school and then underwent surface EMG at three different periods of time: 0, 10, and 70 days. They were divided into a normal control group, a bruxer control group (without device), and an experimental bruxer group who used the device. The bruxer group showed a greater masseter EMG amplitude when compared to the normal group, while the experimental group had deceased activity with a reduction in symptoms. The buccinator EMG spectral analysis of the experimental bruxist group showed asynchronous contractions of the masseter muscle (during jaw opening) after using the Pr6-Fono Facial Exerciser. The normal group also showed asynchronous contractions. Upon correlation of the data between these muscles, the inference is that there is a reduction in bruxism when activating the buccinator muscle.
Resumo:
OBJETIVO: investigar as diferenças entre os achados eletromiográficos dos músculos supra-hióideos direito e esquerdo durante a deglutição de um líquido e um pastoso fino, em sujeitos idosos com doença de Parkinson e idosos sem doença neurológica. MÉTODOS: 30 sujeitos de ambos os sexos participaram deste estudo, 15 idosos sem doença neurológica e os demais com doença de Parkinson. Todos foram submetidos a um protocolo de avaliação clínica e avaliação eletromiográfica de superfície. RESULTADOS: foram constatadas diferenças significantes nos valores entre os sujeitos (f=14.4 e p= 0.000) e entre os lados (f=4.4 e p=0.0037). em relação ao tempo de duração da contração muscular durante a deglutição as diferenças foram significantes apenas entre as consistências (f=8.2 e p=0.005). CONCLUSÃO: a amplitude eletromiográfica foi menor nos sujeitos com doença de Parkinson e maior nos músculos supra-hiódeos do lado direito em ambos os grupos. A duração da contração muscular não diferiu significativamente entre os sujeitos com doença de Parkinson e idosos sem doença neurológica e foi menor para a consistência líquida.
Resumo:
Background: The literature reports that the eccentric muscular action produces greater force and lower myoelectric activity than the concentric muscular action, while the heart rate (HR) responses are bigger during concentric contraction. Objectives: To investigate the maximum average torque (MAT), surface electromyographic (SEMG) and the heart rate (HR) responses during different types of muscular contraction and angular velocities in older men. Methods: Twelve healthy men (61.7 +/- 1.6years) performed concentric (C) and eccentric (E) isokinetic knee extension-flexion at 60 degrees/s and 120 degrees/s. SEMG activity was recorded from vastus lateralis muscle and normalized by Root Mean Square-RMS (mu V) of maximal isometric knee extension at 60 degrees. HR (beats/min) and was recorded at rest and throughout each contraction. The data were analyzed by the Friedman test for repeated measures with post hoc Dunn's test (p<0.05). Results: The median values of MAT (N.m/kg) was smaller and the RMS (mu V) was larger during concentric contraction (C60 degrees/s=2.80 and 0.99; C120 degrees/s=2.46 and 1.0) than eccentric (E60 degrees/s=3.94 and 0.85; E120 degrees/s=4.08 and 0.89), respectively. The HR variation was similar in the four conditions studied. Conclusion: The magnitude of MAT and RMS responses in older men were dependent of the nature of the muscular action and independent of the angular velocity, whereas HR response was not influenced by these factors.
Resumo:
The aim of this study was to evaluate modifications occurring in semitendinous muscle after transposition as a ventral perineal muscle flap using electromyography, ultrasonography, and morphological studies. Ten male crossbreed dogs of 3-4 year old were used. The left semitendinous muscle was cut close to the popliteus lymph node, rotated and sutured at the perineal region. The contralateral muscle was considered as control. Motor nerve conduction studies of both sciatic-tibial nerves, and electromyographic and ultrasonographic examinations of both semitendinous muscles were performed before surgery and 15, 30, 60, and 90 days postoperatively. Semitendinous muscle samples were collected for morphological analysis 90 days after surgery. No alterations were observed in clinical gait examinations, or in goniometrical and electroneuromyographical studies in pelvic limbs after surgery. Electromyography demonstrated that the transposed muscle was able to contract, but atrophy was detected by ultrasonography and morphological analysis.
Resumo:
Este trabalho apresenta estudo retrospectivo de 14 pacientes com mononeuropatia de nervo intercostal (MNI), obtidos dentre 5.560 exames eletromiográficos, realizados de janeiro de 1991 até junho de 2004, em nosso Hospital Universitário. MNI foi encontrada em 14 pacientes, tendo como causas prováveis intervenções cirúrgicas torácicas em 6 (43%), neuropatia por herpes-zoster em 4 (28%), provável neurite de nervo intercostal em 2 (14%), neoplasia pulmonar em 1 (7%) e radiculopatia em 1 (7%). As principais causas de MNI de nosso Serviço são similares às da literatura. Os antidepressivos tricíclicos e anticonvulsivantes foram os fármacos mais utilizados no controle da dor.
Resumo:
This study analyses the blink reflex in 20 adult male patients with terminal chronic renal failure undergoing hemodialysis. Abnormalities were found in ten patients (50%), eight of them with conduction studies showing axonal peripheral neuropathy. Dialysis time was longer for patients with blink reflex alterations (median 55.1 months) than for patients with normal blink reflex (median 36.3 months). Different types of early R1 and late R2 component abnormalities were recorded. The late response abnormalities may indicate subclinical functional or anatomical impairment of the low brainstem reticular formation in patients with chronic renal failure. (C) 2002 Elsevier B.V. Ltd. All rights reserved.
Resumo:
The participation of the superior belly of the omohyoid muscle and anterior belly of the digastric muscle in tongue and head movements was studied eletromyographically in 20 normal young volunteers. A pair of monopolar electrodes was used in each muscle for simultaneous recording of their actions. The muscles act in the following tongue movements: protrusion, right and left lateral movements, placement of the tip of the tongue on soft and hard palates and on the floor of the mouth. The strongest levels of activity of the superior belly of the omohyoid muscle were observed in the placement of the tip of the tongue on the soft palate, coincidentally with a greater dislocation of hyoid bone. Both of the muscles studied did not participate in the head's kinesiology. (C) 1999 Elsevier B.V. Ltd. All rights reserved.
Resumo:
The study's objective was to realize comparisons among different acepromazine, chlorpromazine and methotrimeprazine doses, evaluate parametric changes, test analgesia using press and term algimetry, and evaluate bispectral condition. 90 mongrel dogs were used, male and female, adult, weighting 10 to 15 Kg as a rule, distributed in 9 groups with 10 animals each. At first, second and third groups acepromazine was used at 0,1; 0,05 e 0,025 mg/Kg, respectively. At forth, fifth and sixth groups, chlorpromazine was used at 1,0; 0,5 and 0,25 mg/Kg, respectively. At seventh, eighth and ninth groups, methotrimeprazine at 1,0; 0,5 and 0,25 mg/Kg was used, respectively. All drugs were administered intravenously. objects of study: heart rate (HR), non invasive blood pressure (SAP, MAP, DAP), respiratory rate (f), capnography (ETCO(2)), pulse oxymetry (SatO(2)), mouth and rectal temperature, bispectral index (BIS), electromyography (EMG%), press and term algimetry. Somatic analgesia was evaluated by animal's response to nociceptives stimulus. We concluded that chlorpromazine had more bypotension. Dogs showed higher hypnosis level at: chlorpromazine group, with evident myorelaxation. All groups showed analgesia to thermic and mechanic stimulus. Acepromazine group showed high duration to both pain stimuli. Bispectral index was shorten at chlorpromazine group at 1,0 mg/kg doses, showing higher hypnosis index, and acepromazine was the less depressing considering the bispectral index.