44 resultados para ELASTIC STOCKINGS
Resumo:
The influence of hygrothermal conditioning on mechanical properties of Carall laminates have been investigated by tensile and compression tests. The environmental factors can limit the applications of composites by deteriorating the mechanical properties during service. The importance of temperature at the time of conditioning plays an important role in environmental degradation of such composite materials. In this work, the results show that for carbon fiber/epoxy composites tensile and compression values decrease after hygrothermal conditioning. However, the changes on mechanical properties of Carall are negligible, regardless the hygrothermal conditioning.
Resumo:
This study focuses on the use of hemotoxylin-eosin staining plus fluorescence microscopy for the investigation of elastic fibers in some elastic cartilages. We have observed that elastic fibers are consistently imaged by the proposed procedure and the resolution attained is similar to that obtained with the classical Weigert's fuchsin-resorcin. The results also demonstrate that elastin autofluorescence gives little or no contribution to the final fluorescence and that the use of the confocal laser scanning microscope adds to the resolution, permits the use of thicker sections and reveals of minute structural features. We conclude that this is a relevant tool in elastin research.
Resumo:
BACKGROUND. The extracellular matrix (ECM) has important roles in prostatic development, and marked stromal changes take place in the rat ventral prostate (VP) after androgen deprivation. However, little knowledge exists about individual ECM components.METHODS. The distribution of elastic fibers (EF) and elastic-related fibers (ERF) in the VP of castrated and control rats was investigated, using histochemistry and transmission electron microscopy (TEM).RESULTS. EF are barely detected in the prostatic stroma, but ERF are relatively abundant. Castration results in a relative increase in the number and thickness of ERF. TEM showed an open network of ECM microfibrils throughout the stroma and thin and short EF, which increase in number and thickness after orchiectomy.CONCLUSIONS. The presence of elastic system components in the rat VP warrants the deformability required for the secretion exclusion under the action of smooth muscle cells, and the castration-induced modification may be related to the contraction of the tissue and maintenance of peculiar arrangements of other ECM components. (C) 1997 Wiley-Liss, Inc.
Resumo:
This work presents a methodology for elastic-plastic fracture reliability analysis of plane and axisymmetric structures. The structural reliability analysis is accomplished by means of the FORM analytical method. The virtual crack extension technique based on a direct minimization of potencial energy is utililized for the calculation of the energy release rate. Results are presented to illustrate the performance of the adopted methodology.
Resumo:
We have studied the possibility of associating fluorescence microscopy and hematoxylin-eosin staining for the identification of elastic fibers in elastin-rich tissues. Elastic fibers and elastic laminae were consistently identified by the proposed procedure, which revealed itself to be easy and useful for the determination of such structures and their distribution. The fluorescence properties of stained elastic fibers are due to eosin staining as revealed by fluorescence analysis of the dye in solution, with no or only minor contribution by the elastin autofluorescence. The main advantage of this technique resides in the possibility of studying the distribution of elastic fibers in file material without further sectioning and staining. The use of the confocal laser scanning microscope greatly improved the resolution and selectivity of imaging elastic fibers in different tissues. The determination of the three-dimensional distribution and structure of elastic fiber and laminae using the confocal laser scanning microscope was evaluated and also produced excellent results.
Resumo:
This work reports on the mechanical properties of germanium-rich amorphous carbon-germanium alloys prepared by RF sputtering of a germanium/graphite target under an argon/hydrogen atmosphere. Nano-hardness, elastic modulus and stress were investigated as a function of the carbon content. The stress, which is reduced by the incorporation of carbon, was related to the film structure and to the difference in the Ge-Ge and Ge-C bond length. Contrary to what was expected, the hardness and elastic modulus of the alloys are lower than the corresponding values for pure amorphous hydrogenated germanium film, which in turn has both properties also smaller than those of crystalline germanium. These properties are analyzed in terms of the structural properties of the films. (C) 2001 Elsevier B.V. B.V All rights reserved.
Resumo:
We use the QCD pomeron model proposed by Landshoff and Nachtmann to compute the differential and the total cross-sections for pp scattering in order to discuss a QCD-based approach to the proton form factor. This model is quite dependent on the experimental electromagnetic form factor, and it is not totally clear why this form factor gives good results even at moderate transferred momentum. We exchange the electromagnetic form factor by the asymptotic QCD proton form factor determined by Brodsky and Lepage (BL) plus a prescription for its low energy behavior dictated by the existence of a dynamically generated gluon mass. We fit the data with this QCD inspired form factor and a value for the dynamical gluon mass consistent with the ones determined in the literature. Our results also provide a determination of the proton wave function at the origin, which appears in the BL form factor.
Resumo:
This work is related with the proposition of a so-called regular or convex solver potential to be used in numerical simulations involving a certain class of constitutive elastic-damage models. All the mathematical aspects involved are based on convex analysis, which is employed aiming a consistent variational formulation of the potential and its conjugate one. It is shown that the constitutive relations for the class of damage models here considered can be derived from the solver potentials by means of sub-differentials sets. The optimality conditions of the resulting minimisation problem represent in particular a linear complementarity problem. Finally, a simple example is present in order to illustrate the possible integration errors that can be generated when finite step analysis is performed. (C) 2003 Elsevier Ltd. All rights reserved.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Wood is generally considered an anisotropic material. In terms of engineering elastic models, wood is usually treated as an orthotropic material. This paper presents an analysis of two principal anisotropic elastic models that are usually applied to wood. The first one, the linear orthotropic model, where the material axes L (Longitudinal), R(radial) and T(tangential) are coincident with the Cartesian axes (x, y, z), is more accepted as wood elastic model. The other one, the cylindrical orthotropic model is more adequate of the growth caracteristics of wood but more mathematically complex to be adopted in practical terms. Specifically due to its importance in wood elastic parameters, this paper deals with the fiber orientation influence in these models through adequate transformation of coordinates. As a final result, some examples of the linear model, which show the variation of elastic moduli, i.e., Young's modulus and shear modulus, with fiber orientation are presented.
Resumo:
A 16-year-old girl presented with complaints of recurrent spontaneous pain in the mandibular second molar region. Treatment favored use of a simple uprighting technique involving orthodontic elastic separating rings.
Resumo:
Background: Actinic cheilitis (AC) is a premalignant condition intimately related to exposure of the lips to sun rays. Aim: The objective of this study was to evaluate the elastic and collagen fibers in the lamina propria of AC. The degree of epithelial atypia was correlated with the quantity of elastic and collagen fibers. Materials and Methods: Fifty-one cases were investigated. One slide was stained with hematoxylin-eosin for the evaluation of atypia, the second was stained with Weigert′s resorcin-fuchsin for the assessment of elastic fibers, and the third slide was stained with Mallory′s trichrome for the analysis of collagen fibers. Results: Ordinal logistic regression analysis revealed a significant correlation between the presence of atypia and collagen fibers (P<0.05). Conclusions: It was concluded that there seems to be a reduction in the quantity of collagen fibers in cases of moderate and severe atypia. No correlation was observed between the degradation of elastic system fibers and the grade of dysplasia.
Resumo:
Numerous researchers have studied about nonlinear dynamics in several areas of science and engineering. However, in most cases, these concepts have been explored mainly from the standpoint of analytical and computational methods involving integer order calculus (IOC). In this paper we have examined the dynamic behavior of an elastic wide plate induced by two electromagnets of a point of view of the fractional order calculus (FOC). The primary focus of this study is on to help gain a better understanding of nonlinear dynamic in fractional order systems. © 2011 American Institute of Physics.
Resumo:
Background : Deep venous thrombosis (DVP) is a frequent disease. Prophylaxis is the best means to reduce its incidence, for lowering morbidity and mortality rates and treatment costs caused by its complications. Objective : To evaluate the knowledge and use of any kind of DVT prophylaxis by Brazilian Oral and Maxillofacial surgeons. Materials and Methods : A questionnaire was sent to all Oral and Maxillofacial surgeons associated to the Brazilian College of Oral and Maxillofacial Surgeons that have a valid e-mail address. The data retrieved was evaluated and tabulated. Results : Of the 1100 questionnaires sent, only 4% were retrieved. The 42 retrieved were included in the study. Twenty six of the surgeons do not use any kind of deep venous thrombosis (DVT) prophylaxis, 11 use mechanical means as elastic compressive stockings or pneumatic compressive devices for prophylaxis, and 5 uses low-molecular weight heparins (LMWH) as the choice for prophylaxis. Conclusion : The data collected, despite the low rate of participation (4%) by the surgeons, shows that this subject still does not receive proper attention. Whereas other medical specialties make routine use of prophylactic means maybe the maxillofacial surgeons lack concern on that matter.