176 resultados para ECHOCARDIOGRAPHIC MEASUREMENTS
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Objectives: To assess cardiac morphology and function by means of echocardiograms of children with obstructad breathing while asleep.Methods: the study enrolled 40 children of both sexes, aged from 3 to 11 years; 30 of them had obstructed breathing during sleep (group I) and 10 children were healthy controls (group II). The two groups were similar in terms of sex, age, weight and height. The 40 children underwent echocardiogram, viewing all four chambers during systole and diastole, paying special attention to the right ventricle (RV). These data were compared by means of Student's t test (p < 0.05).Results: In group I, increased diameter and area of the right ventricle were observed during both systole and diastole. There was less variation in RV area between systole and diastole. Reduced left ventricle (LV) diastolic diameter was also observed, together with reduced ejection fraction and reduced contraction.Conclusions: the morphological and functional cardiac abnormalities observed in the RV and LV suggest that, in children, obstructed breathing during sleep can lead to cardiovascular repercussions. These abnormalities may expose these children to increased anesthetic and surgical risks.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Background: The objective of this study was to determine the early echocardiographic predictors of elevated left ventricular end-diastolic pressure (LVEDP) after a long follow-up period in the infarcted rat model.Material/Methods: Five days and three months after surgery, sham and infarcted animals were subjected to transthoracic echocardiography. Regression analysis and receiver-operating characteristic (ROC) curve were performed for predicting increased LVEDP 3 months after MI.Results: Among all of the variables, assessed 5 days after myocardial infarction, infarct size (OR: 0.760; CI 95% 0.563-0.900; p=0.005), end-systolic area (ESA) (OR: 0.761; Cl 95% 0.564-0.900; p=0.008), fractional area change (FAC) (OR: 0.771; CI 95% 0.574-0.907; p=0.003), and posterior wall-shortening velocity (PWSV) (OR: 0.703; CI 95% 0.502-0.860; p=0.048) were predictors of increased LVEDP. The LVEDP was 3.6 +/- 1.8 mmHg in the control group and 9.4 +/- 7.8 mmHg among the infarcted animals (p=0.007). Considering the critical value of predictor variables in inducing cardiac dysfunction, the cut-off value was 35% for infarct size, 0.33 cm(2) for ESA, 40% for FAC, and 26 mm/s for PWSV.Conclusions: Infarct size, FAC, ESA, and PWSV, assessed five days after myocardial infarction, can be used to estimate an increased LVEDP three months following the coronary occlusion.
Resumo:
Realizaram-se mensurações sérica e urinária de fosfatase ácida prostática (PAP) e antígeno prostático específico (PSA) de 20 cães. Os testes de PAP e PSA foram feitos em um equipamento automatizado, com o uso de kits comerciais para humanos. A média de PAP sérico foi de 0,7U/l e urinário 0,U/l. As médias do PSA sérico e urinário foram 0,005ng/dL e 0,004ng/dl, respectivamente. A determinação do dois biomarcadores in vivo é uma nova opção de diagnóstico na medicina veterinária e os valores obtidos devem ser correlacionados com a lesão morfológica da próstata.
Resumo:
OBJECTIVE: To assess structural and functional cardiac changes in asymptomatic pregnant women with chronic arterial hypertension (CAH). METHODS: One hundred pregnant women with CAH underwent conventional Doppler echocardiography. The Student t test was used to compare them with 29 normotensive pregnant women (NT) in their third gestational trimester. RESULTS: Systolic (SBP; mmHg) and diastolic (DBP; mmHg) blood pressure values were higher (p<0.001) in the CAH pregnant women (SBP: 139±19 and DBP: 92± 18) as compared with those of the NT group (SBP: 112±10 and DBP: 74±9). A significant enlargement of the left atrium (4.10±0.48 cm vs 3.6±0.3 cm; p<0.001) and of the left ventricular normalized mass (59.6±19.7 g/cm2,7 vs 41.9±3.4 g/cm2,7; p<0.001) was observed. Cardiac output (CO, L/min) and systolic volume (SV, mL) were significantly higher in the CAH group (CO: 6.0±1.54 vs 4.9±2.1, p<0.01; SV: 77.3±19.8 vs 56.5±25.8, p<0.001). CONCLUSION: Chronic hypertensive pregnant women have structural and functional cardiac changes that justify routine cardiologic assessment, even in the absence of cardiopulmonary symptoms.
Resumo:
Latências do reflexo trigêmino-facial e índices cefalométricos foram analisados em 30 voluntários adultos normais, de 3 diferentes raças, sendo 10 brancos, 10 negros e 10 orientais. Idades variaram de 15 a 59 anos, alturas de 1,6 a 1,8 m e pesos de 60 a 80 kg. Os reflexos trigêmino-faciais foram obtidos por estimulação elétrica unilateral do nervo supra-orbital e captação nos músculos orbicularis oculi, para análise quantitativa de 3 respostas, ipsolateral precoce (R1), ipsolateral tardia (R2i) e contralateral tardia (R2c). Índices cefalométricos foram obtidos multiplicando-se por 100 a razão entre maior diâmetro transverso e maior diâmetro sagital do crânio. As médias dos índices cefalométricos de cada grupo foram compatíveis com as respectivas características raciais. As respostas R1, R2i e R2c não mostraram diferenças de latências estatisticamente significativas entre as 3 diferentes raças analisadas neste estudo.
Resumo:
Doxorubicin is an excellent chemotherapeutic agent utilized for several types of cancer but the irreversible doxorubicin-induced cardiac damage is the major limitation for its use. Oxidative stress seems to be associated with some phase of the toxicity mechanism process. To determine if lycopene protects against doxorubicin-induced cardiotoxicity, male Wistar rats were randomly assigned either to control, lycopene, doxorubicin or doxorubicin + lycopene groups. They received corn oil (control, doxorubicin) or lycopene (5 mg/kg body weight a day) (lycopene, doxorubicin + lycopene) by gavage for a 7-week period. They also received saline (control, lycopene) or doxorubicin (4 mg/kg) (doxorubicin, doxorubin + lycopene) intraperitoneally by week 3, 4 5 and 6. Animals underwent echocardiogram and were killed for tissue analyses by week 7. Mean lycopene levels (nmol/kg) in liver were higher in the doxorubicin + lycopene group (5822.59) than in the lycopene group (2496.73), but no differences in lycopene were found in heart or Plasma of these two groups. Lycopene did not prevent left ventricular systolic dysfunction induced by doxorubicin. However, morphologic examination revealed that doxorubicin-induced myocyte damage was significantly suppressed in rats treated with lycopene. Doxorubicin treatment was followed by increase of myocardium interstitial collagen volume fraction. Our results show that: (i) doxorubicin-induced cardiotoxicity was confirmed by echocardiogram and morphological evaluations; (ii) lycopene absorption was confirmed by its levels in heart, liver and plasma; (iii) lycopene supplementation provided myocyte protection without preventing interstitial collagen accumulation increase; (iv) doxorubicin-induced cardiac dysfunction was not prevented by lycopene supplementation; and (v) lycopene depletion was not observed in plasma and tissues from animals treated with doxorubicin.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The present work aimed to evaluate udders of Bergamasca ewes and their correlation with milk yield in a mix system of milk yield. Seventy-seven ewes were fed with balanced concentrate starting 20 days before lambing until the end of the experiment. The lambs stayed with their mothers in pastures during the day and were separated at night. They returned to their mothers after the morning milking and were weaned at 45 days of age. Forty-eight hours after lambing, ewes were machine milked once daily at 7 am and the milk yield was recorded for a period of 60 days. Measurements of circumference, depth and width of the udder, and width and length of teats, at 30 and 60 days, were taken. A higher average daily yield of commercial milk was observed after lambs weaning (0.509 vs. 0.435 kg/ewe/day) than before. In the same way, the correlations between udder depth, circumference and width and milk yield were positive and significant only after weaning (0.74, 0.75 and 0.62, respectively). Udder measures had positive correlations with milk yield and can be used in programs of milk yield improvement. (c) 2007 Elsevier B.V. All rights reserved.
Resumo:
The aim of this in vitro study was to evaluate the influence of pit and fissure sealants on fluorescence readings using lasers. We selected 166 permanent molars and randomly divided them into 4 groups which were each treated with a different sealant (a commercially available clear sealant, 2 opaque sealants and an experimental nanofilled clear sealant). The teeth were independently measured twice by 2 experienced dentists using conventional laser fluorescence (LF) and a laser fluorescence pen device (LFpen), before and after sealing, and again after thermocycling to simulate the thermal stressing between the tooth and the dental materials. Friedman test showed no statistically significant changes using LF and LFpen for the commercial clear sealant group, although values tended to increase after sealing. However, the values increased significantly after thermocycling. There was a statistically significant decrease in fluorescence after application of opaque sealants. After application of the experimental nanofilled clear sealant, LF values increased only after thermocycling, whereas the LFpen values increased after sealing and after thermocycling as well. The intraclass correlation coefficient ranged from 0.87 to 0.96 for interexaminer and 0.82 to 0.94 for intraexaminer reproducibility. It was shown that pit and fissure sealants influence LF and LFpen readings, with the values increasing or decreasing according to the material used. In conclusion, both laser fluorescence devices could be useful as an adjunct to detect occlusal caries under unfilled clear sealants. Nevertheless, surfaces sealed with clear nanofilled material could be assessed using only the LF device. Copyright (C) 2008 S. Karger AG, Basel.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)