18 resultados para Dual frequency


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Aiming to evaluate the methodologies of surveys related with the specifications of Geo-referencing Rural Parcels in Brazil, established by INCRA (National Institute of Colonization and Agrarian Reform), in attendance to the Law 10.267/01, and considering aspects of precision and accuracy, a test area was set up in the Assentamento Florestan Fernandes, in the county of Presidente Bernardes, SP. This area was subdivided in three sub-areas in order to simulate the existence of three contiguous rural parcels. The first stage of work consisted in the implantation and determination of the control points coordinates in their respective areas. These control points were determined by the process of direct transport, using dual frequency (L1/L2) GPS receivers and through the process of traverse with baselines of up to 20 km, using single frequency receivers (L1). The coordinates of the points of the perimeter of the three sub-areas were determined using single frequency GPS receivers, from two survey methods, both using static relative positioning. The first one, so called traverse, each point that delimits the property was occupied successively, starting from the control point and closing at another. In other, denominated double irradiation, each point of the property was irradiated from two control points. These procedures were accomplished with the intention to define and to implement a mistake control strategy, to realize redundancy measurements and to use an adjustment method correctly, to obtain trustworthily values in the patterns demanded in each kind of survey. With the data collected and processed some analyses could be accomplished from the discrepancies between the coordinates obtained by different methodologies. The results show that this test area may be used to validate other methodologies and equipments. The results were satisfactory and attended the specifications of Geo-referencing Rural Parcel.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The research trend for harvesting energy from the ambient vibration sources has moved from using a linear resonant generator to a non-linear generator in order to improve on the performance of a linear generator; for example, the relatively small bandwidth, intolerance to mistune and the suitability of the device for low-frequency applications. This article presents experimental results to illustrate the dynamic behaviour of a dual-mode non-linear energy-harvesting device operating in hardening and bi-stable modes under harmonic excitation. The device is able to change from one mode to another by altering the negative magnetic stiffness by adjusting the separation gap between the magnets and the iron core. Results for the device operating in both modes are presented. They show that there is a larger bandwidth for the device operating in the hardening mode compared to the equivalent linear device. However, the maximum power transfer theory is less applicable for the hardening mode due to occurrence of the maximum power at different frequencies, which depends on the non-linearity and the damping in the system. The results for the bi-stable mode show that the device is insensitive to a range of excitation frequencies depending upon the input level, damping and non-linearity.