55 resultados para Distributed Material Flow Control
Resumo:
This work describes an optical device for the simultaneous recording of shadowgrams and schlieren images, and some results are presented concerning its applications to the study of plasma assisted flow control in airfoil models. This approach offers many advantages in comparison to other methods, specially because the use of tracer particles (like smoke in wind tunnels) is not required for the experiments, thus avoiding contaminations in the electric discharges or air flows. Besides, while schlieren images reveal the refractive index gradients in the area of study, shadowgrams detect the second order spatial derivatives of the refractive indexes. Therefore, the simultaneous recording of these different images may give interesting information about the phenomena under study. In this paper, these images were used to confirm the existence of vortex structures in the flow induced by corona discharges on airfoil models. These structures are a possible explanation for the effects of drag reduction and lift force increasing, which have been reported in experiments of plasma assisted Aerodynamics.
Resumo:
This work describes an optical device for the simultaneous recording of shadowgrams and schlieren images, and some results are presented concerning its application to the study of plasma assisted flow control in airfoil models. This approach offers many advantages in comparison to other methods, specially because the use of tracer particles (like smoke in wind tunnels) is not required for the experiments, thus avoiding contaminations in the electric discharges or air flows. Besides, while schlieren images reveal the refractive index gradients in the area of study, shadowgrams detect the second order spatial derivatives of the refractive indexes. Therefore, the simultaneous recording of these different images may give interesting information about the phenomena under study.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Com a finalidade de quantificar o desempenho dos sistemas de debulhamento e limpeza da colhedora Penha CLM-350,, estudou-se as perdas percentuais era grão de milho, ocorridos na saída de palhas, bem como a porcentagem de impurezas, presente no milho ensacado. Tomando-se como 100% os grãos de milho colhidos pelo sistema espigador, determinou-se o valor percentual perdido pelos sistemas de debulhamento e limpeza, bem como a porcentagem de impurezas presente nos grãos de milho ensacado, nos diversos tratamentos estudados. O teor médio de umidade foi de 15,78% (b.u.). Os tratamentos correspondentes ao sistema de debulhamento e limpeza são as velocidades periféricas do debulhador ou as rotações do aspirador em faces da configuração geométrica da máquina. Os resultados obtidos foram estudados através da análise de variância, empregando-se os testes F, aos níveis de 1% e 5% de probabilidade e o teste Tukey, para a comparação estatística entre as médias. A análise estatística para verificar a influência da rotação do aspirador, era relação a porcentagem de grãos de milho perdidos na saída de palhas, mostrou diferenças altamente significativas, podendo-se admitir uma relação direta entre os dois parâmetros nas condições do ensaio. Com relação a rotação do aspirador e a porcentagem de impurezas, presentes nos grãos de milho ensacados, os testes das médias revelaram significância entre os tratamento D (1241,7 rpm) e E (820 rpm) sendo que este último apresentou a maior média. Uma análise mais acurada dos resultados sugere que a porcentagem de impurezas, estaria mais na dependência das relações de fluxo através da colhedora, do que propriamente do regime do aspirador.
Resumo:
Cm vistas a estudar o efeito do sistema de debulhamento na qualidade dos grãos de milho, realizou-se o presente trabalho, onde foram estudados os danos mecânicos sofridos pelos grãos, bem como os danos mecânicos invisíveis, evidenciados pelos testes de germinação. Nos diversos tratamentos estudados, determinou-se a porcentagem de umidade presente nos grãos de milho. Definiu-se a velocidade periférica do debulhador, pelo diâmetro (300 mm) do mesmo e as rotações, para os diversos tratamentos. O delineamento experimental foi de blocos ao acaso com 5 tratamentos e 6 repetições onde foram estudados os valores percentuais de grãos inteiros e quebrados, os teores de umidade correspondentes e os valores de germinação através da análise de variância. Empregou-se o teste F aos níveis de 1% e 5% de probabilidade e o teste Tukey para comparação entre as médias. da análise pode-se concluir que em relação ao teor de umidade dos grãos, os tratamentos não diferiram estatisticamente.
Resumo:
A colheita é a operação final de campo do processo produtivo, e por isso os fatores que interferem na mesma devem ser observados e avaliados atentamente para reduzir ao mínimo as perdas nessa etapa. O objetivo deste trabalho foi avaliar a influência dos sistemas de adubação (em pré-semeadura e na semeadura) e dos consórcios de culturas intercalares (milho+mucuna-cinza-anã, milho+guandu-anão e milho+lablab) nas variáveis de colheita da cultura do milho em sistema plantio direto. O experimento foi realizado na UNESP de Jaboticabal - SP, no período de safra normal, utilizando-se do delineamento em blocos ao acaso, no esquema fatorial (2 x 3), com quatro repetições. Os componentes avaliados na colheita foram: diâmetro do colmo, altura de inserção da primeira espiga, altura da planta, número de espigas por planta, índice de espiga, número de fileiras na espiga, biomassa seca da palhada no solo, estande final, produtividade de grãos, fluxos de grãos, de palha e de sabugo e perdas na colheita. Os resultados demonstraram que o diâmetro do colmo, a altura de inserção da primeira espiga e a altura de plantas apresentaram maiores valores para o sistema de adubação na semeadura. O número de fileiras, espigas viáveis, índice de espiga, estande final, biomassa seca da palhada, produtividade, fluxos de palha, de sabugo, de grãos e as perdas na colheita não foram afetados pelos sistemas de adubação e os consórcios.
Resumo:
Purpose: To evaluate the effect of 2 postpolymerization treatments on toothbrushing wear (weight loss) and surface roughness of 3 autopolymerized reline resins-Duraliner II (D) (Reliance Dental), Kooliner (K) (Coe Laboratories), and Tokuso Rebase Fast (T) (Tokuyama Dental)-and 1 heat-polymerized resin, Lucitone 550 (L) (Dentsply International). Materials and Methods: Specimens (40 x 10 x 2mm) of each material (n = 24) were prepared and divided into 3 groups: control (no postpolymerization treatment); water bath (immersion in water at 55°C); and microwave (microwave irradiation). Specimens were dried until constant weight was achieved and the surface roughness (Ra) was measured. Tests were performed in a toothbrush machine using 20,000 strokes of brushing at a weight of 200 g, with the specimens immersed in 1:1 dentifrice/water slurry. Specimens were reconditioned to constant weight and the weight loss (mg) and surface roughness were evaluated. Data were analyzed by 2-way analysis of variance and followed by Tukey test (α = .05). Results: In the control group, the weight loss of materials D and T was lower (P < .05) than that of L. No differences among materials were found after postpolymerization treatments (P > .05). The weight loss of material T (control = 0.5 mg) was significantly increased (P < .05) after postpolymerization treatments (water bath = 1.9 mg; microwave = 1.8 mg). For materials K and T, the toothbrushed surface roughness was higher (P < .05) after microwave and waterbath postpolymerization treatments. Material L showed increased surface roughness after microwave postpolymerization treatment. Conclusion: The toothbrushing wear resistance of L was not superior to the reline resins. The postpolymerization treatments did not improve the toothbrushing wear resistance of the materials and produced an increased surface roughness for materials L, K, and T.
Resumo:
The aim of this study was to determine the effect of the exposure of different endodontic materials to different dye solutions by evaluating the optical density of the dye solutions. Seventy-five plastic tubes were filled with one of the following materials: AH Plus, Sealapex, Portland cement, MTA (Angelus and Pro Root) and fifteen control plastic tubes were not. Each specimen of material and control was immersed in a container with 1 ml of each dye solution. A 0.1 ml-dye solution aliquote was removed before immersion and after 12, 24, 48 and 72 hours of each specimen immersion to record its optical density (OD) in a spectrophotometer. Statistical analysis was performed with ANOVA and Tukey tests (5%). No significant difference was found among any of the solution OD values for AH Plus cement. Portland cement promoted different OD values after 12 hours of immersion. MTA-Angelus cement presented different OD values only for 2% rhodamine B and the MTA-Pro Root cement presented different OD values in all 2% rhodamine B samples. Sealapex cement promoted a reduction in the India Ink OD values. Dye evaluation through OD seems to be an interesting method to select the best dye solution to use in a given marginal leakage study.
Resumo:
Purpose: This in vitro study aimed to evaluate the effect of different fruit juice drinks available in the Brazilian market on smear layer removal and dentinal tubules opening, as well as to verify the effect of toothbrushing subsequently to the juices exposure. Methods: Dentin specimens were prepared and randomly distributed into the control group (distilled water) and twelve types of fruit juice drinks (cashew, orange, mandarin, apple, passion fruit, guava, strawberry, grape, mango, pear, peach, pineapple). The following treatments were applied: immersion or immersion + brushing. After preparation for SEM, photomicrographs were assessed using an index of smear layer removal. Results: No significant differences regarding smear layer removal and dentinal tubules exposure could be observed between the groups after both treatments (Kruskal-Wallis, post-hoc paired comparisons, P>0.05). The control solution and the fruit juice drinks were not able to remove smear layer and to open dentinal tubules. Significant difference between the applied treatments was detected only for the mango juice group (Mann-Whitney, P<0.05). Conclusion: Under the experimental conditions, the different fruit juice drinks did not promote significant alterations on human radicular dentin morphology regardless of the subsequent application of brushing procedures. Copyright: © 2011 Zandim et al.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Engenharia Mecânica - FEG
Resumo:
Pós-graduação em Agronomia (Energia na Agricultura) - FCA
Resumo:
Pós-graduação em Engenharia Elétrica - FEIS