152 resultados para Disinfected impressions


Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work attempts to establish dermatological identification patterns for Brazilian enidarian species and it probable correlation with envenoming, severity In all observational prospective study, one hundred and twenty-eight patients from the North Coast re-ion of São Paulo State, Brazil were seen between 2002 and 2008. About 80% of these Showed only local effects (erythema, edema, and pain) with small, less than 20 cm, oval or round skin marks and impressions from Small tentacles. Approximately 20% of the victims had long, more than 20 cm, linear and crossed marks with frequent systemic phenomena, such as malaise, vomiting, dyspnea, and tachycardia. The former is compatible with the common hydromedusa from Southeast and Southern Brazil (Olindias sambaquiensis). The long linear marks with intense pain and systemic phenomena are compatible with envenoming, by the box jellyfish Tamoya haplonema and Chiropsalmus quadrumanus and the hydrozoan Portuguese man-of-war (Physalis physalis). There was an association between Skin marks and probable accident etiology. This simple observation rule can be indicative of severity as the Cubozoa Class (box jellyfish) and Portuguese man-of-war cause the most severe accidents. In such cases, medical attention, including intensive care, is important, as the systemic manifestations call be associated with death.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A desinfecção de todo e qualquer molde obtido é medida de biossegurança obrigatória na atividade clínica. Tão importante quanto a desinfecção é a seleção do método e da solução desinfetante a ser utilizada para cada material de moldagem. É imperativo que a capacidade de reprodução de detalhes, a estabilidade dimensional e o grau de umedecimento (ou molhabilidade) não sejam criticamente afetados. O propósito deste trabalho foi avaliar o grau de umedecimento de uma marca comercial de poliéter (Impregum F) por três diferentes marcas comerciais de gesso tipo IV (Herostone, Durone e Polirock), após sua desinfecção por aerossóis de hipoclorito de sódio 1% (líquido de Milton) ou glutaraldeído 2% (Glutalabor II). Foram confeccionados 45 moldes de poliéter, os quais, em grupos de 15, receberam aerossóis de água (Grupo Controle), Líquido de Milton ou Glutalabor II. em seguida, sobre a superfície dos moldes foram confeccionados modelos de gesso tipo IV, em número de 5 para cada marca de gesso. Após seu seccionamento mediano e preparo da superfície de corte, os modelos foram levados ao microscópio Carl Zeiss para leitura do ângulo de contato. Os resultados obtidos permitiram concluir que: a) a capacidade de umedecimento do poliéter por diferentes marcas comerciais de gesso tipo IV variou para os gessos estudados; b) o gesso Durone adaptou-se melhor aos moldes de poliéter do que os gessos Herostone e Polirock; c) a desinfecção dos moldes com aerossóis de hipoclorito de sódio 1% (líquido de Milton) ou glutaraldeído 2% (Glutalabor) não afetou a adaptação entre os gessos e o poliéter.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: The aim of this study was to compare 2 different methods of assessment of implants at different inclinations (90 degrees and 65 degrees)-with a profilometer and AutoCAD software. Materials and Methods: Impressions (n = 5) of a metal matrix containing 2 implants, 1 at 90 degrees to the surface and 1 at 65 degrees to the surface, were obtained with square impression copings joined together with dental floss splinting covered with autopolymerizing acrylic resin, an open custom tray, and vinyl polysiloxane impression material. Measurement of the angles (in degrees) of the implant analogs were assessed by the same blinded operator with a profilometer and through analysis of digitized images by AutoCAD software. For each implant analog, 3 readings were performed with each method. The results were subjected to a nonparametric Kruskal-Wallis test, with P <= .05 considered significant. Results: For implants perpendicular to the horizontal surface of the specimen (90 degrees), there were no significant differences between the mean measurements obtained with the profilometer (90.04 degrees) and AutoCAD (89.95 degrees; P=.9142). In the analyses of the angled implants at 65 degrees in relation to the horizontal surface of the specimen, significant differences were observed (P=.0472) between the mean readings with the profilometer (65.73 degrees) and AutoCAD (66.25 degrees). Conclusions: The degrees of accuracy of implant angulation recording vary among the techniques available and may vary depending on the angle of the implant. Further investigation is needed to determine the best test conditions and the best measuring technique for determination of the angle of the implant in vitro.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: The aim of this study was to compare splinting techniques for impression copings of osseointegrated implants with different angulations.Materials and Methods: Replicas (N = 24) of a metal matrix (control) containing two implants at 90 degrees and 65 degrees in relation to the horizontal surface were obtained by using four impression techniques: Technique 1 (T1), direct technique with square copings without union in open trays; Technique 2 (T2), square copings splinted with dental floss and autopolymerizing acrylic resin; Technique 3 (T3), square copings splinted with dental floss and autopolymerizing acrylic resin, sectioned and splinted again with autopolymerizing acrylic resin; Technique 4 (T4), square copings splinted with prefabricated acrylic resin bar. The impression material was polyether. The replicas were individually scanned to capture the images, which were assessed in a graphic computation program. The program allowed the angulation between the bases of the replicas and the reading screws to be measured. The images of the replicas were compared with the matrix image (control), and the differences in angulations from the control image were calculated. The analysis of variance and the Tukey test for comparisons (p < 0.05) were used for statistical analysis.Results: All groups showed significant differences in the implant angulations in comparison with the control group (p < 0.05). Group T1 showed the highest difference (1.019 degrees) followed by groups T2 (0.747 degrees), T3 (0.516 degrees), and T4 (0.325 degrees), which showed the lowest angular alteration compared to the control group. There were significant differences between inclined and straight implants in all the groups, except in group T4.Conclusions: Based on the results, the splinting of pick-up impression copings is indicated for osseointegrated implant impressions. The square copings splinted with a prefabricated acrylic resin bar presented the best results among the pick-up impression techniques evaluated in this study.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: The purpose of this study was to evaluate the color stability of MDX4-4210 maxillofacial elastomer with opacifier addition submitted to chemical disinfection and accelerated aging.Materials and Methods: Ninety specimens were obtained from Silastic MDX4-4210 silicone. The specimens were divided into three groups (n = 30): Group I: colorless, Group II: barium sulfate opacifier, Group III: titanium dioxide opacifier. Specimens of each group (n = 10) were disinfected with effervescent tablets, neutral soap, or 4% chlorhexidine gluconate. Disinfection was conducted three times a week for 2 months. Afterward, the specimens were submitted to different periods of accelerated aging. Color evaluation was carried out after 60 days (disinfection period) and after 252, 504, and 1008 hours of accelerated aging, using a reflection spectrophotometer. Color alterations were calculated by the CIE L*a*b* system. Data were analyzed by three-way ANOVA and Tukey test (alpha = 0.05).Results: Group II exhibited the lowest color change, whereas Group III the highest (p < 0.05), regardless of the chemical disinfection and accelerated aging periods.Conclusion: Opacifier addition, chemical disinfection, and accelerated aging procedures affected the color stability of the maxillofacial silicone.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The failure of facial prostheses is caused by limitations in their flexibility and durability. Therefore, we evaluated the effects of disinfection and aging on Shore A hardness and deterioration of a facial silicone with different pigmentations. Twenty samples with addition of each pigment (ceramic (C), make-up (M)) and without pigment (L) were made. For each pigment type and no pigment, 10 samples were subjected to two types of disinfectant solution (soap (S) and Efferdent (E)), totaling sixty samples. The specimens were disinfected three times per week for 60 days, and subjected to accelerated aging for 1008 h. The hardness of the facial silicone was measured with a durometer, and its deterioration was evaluated by obtaining the weight difference over time. Both the hardness and weight of the samples were measured at baseline, after chemical disinfection, and periodically during accelerated aging (252, 504, and 1008 h). Deterioration was calculated during the periods between baseline and chemical disinfection, and between baseline and each aging period. The results were analyzed using three-way repeated measures ANOVA and the Tukey's HSD Post-hoc test (alpha = 0.05). Specifically, samples containing pigment exhibited significantly higher hardness and deterioration values than those lacking pigment (P < 0.05). In addition, period of time (disinfection and accelerated aging) statistically increased the hardness and deterioration values of the silicone (P < 0.05). It can be concluded that both pigment and time statistically affected the hardness and deterioration of the silicone elastomer. (c) 2012 Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Computer-aided design/computer-aided manufacturing images can be taken through either direct or indirect imaging. For the indirect systems, the digitalization is obtained from the impression material or cast, and for the direct ones the image is taken directly from the mouth using intraoral scanners.The direct acquisition systems have been constantly improved because these are less invasive, quicker, and more precise than the conventional method. Besides, the digital images can be easily stored for a long time. Therefore, the aim of this paper was to describe and discuss based on the literature the main direct image acquisition systems available on the market: CEREC Bluecam (Sirona), Lava C.O.S. System (3M ESPE), iTero System (Cadent/Straumann), and E4D System (D4D Technologies).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this study was to evaluate the color stability of a maxillofacial elastomer with the addition of a nanoparticle pigment and/or an opacifier submitted to chemical disinfection and artificial aging. Specimens were divided into four groups (n = 30): group I: silicone without pigment or opacifier, group II: ceramic powder pigment, group III: Barium sulfate (BaSO(4)) opacifier, and group IV: ceramic powder and BaSO(4) opacifier. Specimens of each group (n = 10) were disinfected with effervescent tablets, neutral soap, or 4% chlorhexidine gluconate. Disinfection was done three times a week during two months. Afterward, specimens were submitted to different periods of artificial aging. Color evaluation was initially done, after 60 days (disinfection period) and after 252, 504, and 1008 h of artificial aging with aid of a reflection spectrophotometer. Data were analyzed by three-way ANOVA and Tukey test (alpha = 0.05). The isolated factor disinfection did not statistically influence the values of color stability among groups. The association between pigment and BaSO(4) opacifier (GIV) was more stable in relationship to color change (Delta E). All values of Delta E obtained, independent of the disinfectant and the period of artificial aging, were considered acceptable in agreement with the norms presented in literature. (C) 2011 Society of Photo-Optical Instrumentation Engineers (SPIE). [DOI: 10.1117/1.3625401]

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: To evaluate patients' perceptions of alterations occurring after chin bone harvesting.Materials and Methods: Thirty patients were evaluated subjectively by visual analog scale-related sensitivity, facial aesthetics, eating, speaking, and lower lip movement, during 12 months. Objective analysis used the static light touch neurosensorial test. The statistical analysis was executed with Friedman test with P < 0.05 for both samples.Results: Subjective analysis revealed no alterations (1) to facial aesthetics, eating, speaking or lower lip movement but sensitivity of the mental region went from a lot of alteration initially (5) to little at the end of the study (3). Objective analysis results showed normal sensitivity (1) in the region after 12 months.Conclusion: The discrepancy between subjective and objective analyses may be indicative of the limited precision of clinical testing for subjective impressions assessment. (Implant Dent 2012;21:411-414)