115 resultados para Differences-in-Differences method
Resumo:
A study was made to compare dry matter, crude protein and gross energy digestibility of corn silage, associated to concentrate, through in vitro and in vivo digestion techniques. A completely randomized design was used, with two treatments and nine replications, involving three assays. The in vivo digestion assay was conducted with 12 Holstein heifers, on a 24 h permanent sample collection. The in vitro digestion assay was achieved with three collection methods: manual (M), vacuum pump (VP) and nasoesophagic (N). The collection methods VP and M can he used to determine the dry matter digestibility, instead of in vivo method, for the present study ration. The digestion methods influenced the DM, CP and GE digestibility for the studied ration.
Resumo:
OBJETIVOS: propor padrão de normalidade das dimensões do IVventrículo e estudar suas características em neurocisticercose. MÉTODO: em um grupo controle (GC) constituído de 114 indivíduos com tomografias normais e em outro grupo composto de 80 doentes com neurocisticercose (GN), mediram-se a distância fronto-polar de ventrículos laterais (FP) e os diâmetros craniano interno (Cr), ântero-posterior (AP) e látero-lateral (LL) do IVº ventrículo para a padronização de seis índices. RESULTADOS: AP/Cr, AP/LL e AP/FP foram os índices mais discriminatórios e apresentaram, em GC, valores médios de 0,063, 0,267 e 0,582, respectivamente. em GN os valores foram estatisticamente superiores a GC. Selecionaram-se 51 doentes do GN com índice> ou =2 desvios-padrão da média em GC. Neles, AP/Ll foi> ou =1 em 95% doentes com derivação liquórica e em 88% com depressão, ocorrendo em 73% com evolução satisfatória e todos que faleceram. CONCLUSÃO: AP/Cr, AP/LL e, principalmente, AP/FP são representativos das dimensões do IVventrículo.
Resumo:
The Whitham modulation equations for the parameters of a periodic solution are derived using the generalized Lagrangian approach for the case of the damped Benjamin-Ono equation. The structure of the dispersive shock is considered in this method.
Resumo:
A method was developed for the differential-pulse cathodic stripping voltammetric determination of ceftazidime with a hanging mercury drop electrode using its reduction peak at -0.43 V in Britton-Robinson buffer pH 4.0. The optimum accumulation potential and time were -0.15 V and up to 60 s, respectively. Linear calibration graphs were obtained from 1 x 10(-8) M and 1.5 x 10(-7) M. The limit of determination was calculated to be 5 x 10(-9) M. The coefficient of variation was 4% (n = 7) at 1 x 10(-7) M ceftazidime. The effect of various components of urine on the voltammetric response was studied, and creatinine, uric acid, urea, and glucose were shown to interfere in the method. Ceftazidime bound to human albumin gives a unique stripping peak at -0.48 V. Recoveries of 87% +/- 2% of the ceftazidime (n = 5) were obtained from urine spiked with 1.27 mu g ml(-1) using C-18 solid phase extraction cartridges. (C) 1997 Academic Press.
Resumo:
The identification of ground control on photographs or images is usually carried out by a human operator, who uses his natural skills to make interpretations. In Digital Photogrammetry, which uses techniques of digital image processing extraction of ground control can be automated by using an approach based on relational matching and a heuristic that uses the analytical relation between straight features of object space and its homologous in the image space. A build-in self-diagnosis is also used in this method. It is based on implementation of data snooping statistic test in the process of spatial resection using the Iterated Extended Kalman Filtering (IEKF). The aim of this paper is to present the basic principles of the proposed approach and results based on real data.
Resumo:
Objectives: The objectives of this study were to assess the fluoride concentration in the public water supply and the prevalence of dental fluorosis in schoolchildren between 7 and 15 years old, living in a peripheral district of the municipality of Bauru. Material and Methods: For this, fifty two water samples were collected on three different days of one week. These samples were analyzed for fluoride by means of the ion-sensitive electrode method (Orion 9609) coupled to a potentiometer (Procyon, model 720). In this method, 1.0 mL of TISAB II (Orion) was added to 1.0 mL of the sample. For the epidemiological survey of fluorosis, 52 schoolchildren of both genders, aged between 7 and 15 were assessed, with prior authorization from their caretakers. Only one person examined the children, after supervised toothbrushing and drying with cotton wool rolls. The TF index was used. Results: The fluoride concentrations in the water samples ranged from 0.62 to 1.20 mg/L, with a mean of 0.9 mg/L. The prevalence of dental fluorosis was 33%, with severity ranging from TF1 to TF4 (Kappa of 0.73 and concordance of 83.33%). Conclusions: The results from the analysis of water samples indicated a fluoride concentration greater than recommended for Bauru. The fluorosis levels found were higher than expected for a peripheral district, in which water is one of the few sources of fluoride.
Resumo:
The GPS observables are subject to several errors. Among them, the systematic ones have great impact, because they degrade the accuracy of the accomplished positioning. These errors are those related, mainly, to GPS satellites orbits, multipath and atmospheric effects. Lately, a method has been suggested to mitigate these errors: the semiparametric model and the penalised least squares technique (PLS). In this method, the errors are modeled as functions varying smoothly in time. It is like to change the stochastic model, in which the errors functions are incorporated, the results obtained are similar to those in which the functional model is changed. As a result, the ambiguities and the station coordinates are estimated with better reliability and accuracy than the conventional least square method (CLS). In general, the solution requires a shorter data interval, minimizing costs. The method performance was analyzed in two experiments, using data from single frequency receivers. The first one was accomplished with a short baseline, where the main error was the multipath. In the second experiment, a baseline of 102 km was used. In this case, the predominant errors were due to the ionosphere and troposphere refraction. In the first experiment, using 5 minutes of data collection, the largest coordinates discrepancies in relation to the ground truth reached 1.6 cm and 3.3 cm in h coordinate for PLS and the CLS, respectively, in the second one, also using 5 minutes of data, the discrepancies were 27 cm in h for the PLS and 175 cm in h for the CLS. In these tests, it was also possible to verify a considerable improvement in the ambiguities resolution using the PLS in relation to the CLS, with a reduced data collection time interval. © Springer-Verlag Berlin Heidelberg 2007.
Resumo:
The objective of this paper is to show a methodology to estimate transmission line parameters. The method is applied in a single-phase transmission line using the method of least squares. In this method the longitudinal and transversal parameters of the line are obtained as a function of a set of measurements of currents and voltages (as well as their derivatives with respect to time) at the terminals of the line during the occurrence of a short-circuit phase-ground near the load. The method is based on the assumption that a transmission line can be represented by a single circuit π. The results show that the precision of the method depends on the length of the line, where it has a better performance for short lines and medium length. © 2012 IEEE.
Resumo:
This study aimed to analyze the electromyographic (EMG) activity of iliocostalis lumborum (IL), internal oblique (IO) and multifidus (MU) and the antagonist cocontraction (IO/MU and IO/IL) during the performance of Centering Principle of Pilates Method. Participating in this study were eighteen young and physically fit volunteers, without experience in Pilates Method, divided in two groups: low back pain group (LBPG, n = 8) and control group (CG, n = 10). Two isometric contractions of IO muscles (Centering Principle) were performed in upright sitting posture. EMG signal amplitude was calculated by Root Mean Square (RMS), which was normalized by RMS maximum value. The common area method to calculate the antagonist cocontraction index was used. MU and IO activation and IO/MU cocontraction (. p < 0.05) were higher in CG. The CG therefore showed a higher stabilizer muscles recruitment than LBPG during the performance of Centering Principle of Pilates Method. © 2012 Elsevier Ltd.
Resumo:
Environmental problems caused by synthetic fungicides have increased the search for alternative methods of control of plant diseases. The objective was to evaluate the effect of essential oil of citronella grass, on the fungus Rhizoctonia solani, in different methods of in vitro fungitoxicity. We used a randomized design in a factorial design with four replications, where the factors were composed of four methods for assessing the in vitro fungitoxicity of the essential oil of citronella grass (essential oil diluted in Tween 80 (0.5%) and embedded in the culture medium PDA (potato dextrose agar) still melting, essential oil diluted in Tween 80 (0.5%) and distributed on the surface of the PDA; oil essential diluted in Tween 80 (0.5%) and distributed on filter paper attached to the inner surface of the lid of the Petri dish, pure essential oil and distributed on the surface of the culture medium, and control) and five evaluation periods (2, 4, 6, 8 and 10 days of incubation). Was used 0.25μL mL-1 of citronella oil in all treatments. Of the treatments evaluated the use of pure oil distributed on the surface of the culture medium was more effective in reducing the mycelial diameter in all evaluations. In this method the rate of mycelial growth was 9,02 mm day-1, reaching in last evaluation 79,77 mm.
Photodynamic potential of curcumin and blue LED against streptococcus mutans in a planktonic culture
Resumo:
Background: The photodynamic therapy (PDT) involves the use of light of specific wavelength to activate a nontoxic photosensitizing agent or dye in the presence of oxygen for eradication of target cells. In dentistry, this therapy is used to suppress the growth of microorganisms involved directly with dental decay and periodontitis process. There are evidences that curcumin dye is able to control microbial activity when illuminated with specific wavelength. The purpose of this study was to evaluate the in vitro efficacy of PDT using curcumin dye (Cur-C) in combination with a blue LED (L) device on a planktonic model of Streptococcus mutans ( S. mutans). Methods: Suspensions (0.5mL) containing S. mutans at 1×107CFUmL-1 were prepared and divided into 4 groups: Group C-L- (control: no treatment and 1 experimental condition), Group C+L- (curcumin at 3 different concentrations: 2000; 4000 and 8000μM and 3 experimental conditions), Group C-L+ (LED at 3 different dosages: 24, 48 and 72Jcm-2 and 3 experimental conditions), and Group C+L+ (PDT group: curcumin at respective concentrations combined to LED dosages and 9 experimental conditions). Samples of each experimental condition were cultured in Petri dishes of BHI agar. Incubation in micro-aerophilia at 37°C for 48h was performed for subsequent visual counting of CFU/mL. Data were transformed into log10 and analyzed by two-way ANOVA and Tukey's test at p<0.05. Results: Group C. +. L+, in specific experimental conditions, demonstrated a log bacterial reduction 70% higher than Group C. -. L-. Both groups C. -. L+ and C. +. L- presented a slight decrease in log bacterial counting. Conclusion: This in vitro method was able to reduce the number of S. mutans in a planktonic suspension. © 2013 Elsevier B.V.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
This paper aims to contribute to the three-dimensional generalization of numerical prediction of crack propagation through the formulation of finite elements with embedded discontinuities. The analysis of crack propagation in two-dimensional problems yields lines of discontinuity that can be tracked in a relatively simple way through the sequential construction of straight line segments oriented according to the direction of failure within each finite element in the solid. In three-dimensional analysis, the construction of the discontinuity path is more complex because it requires the creation of plane surfaces within each element, which must be continuous between the elements. In the method proposed by Chaves (2003) the crack is determined by solving a problem analogous to the heat conduction problem, established from local failure orientations, based on the stress state of the mechanical problem. To minimize the computational effort, in this paper a new strategy is proposed whereby the analysis for tracking the discontinuity path is restricted to the domain formed by some elements near the crack surface that develops along the loading process. The proposed methodology is validated by performing three-dimensional analyses of basic problems of experimental fractures and comparing their results with those reported in the literature.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Responses of the geometric indices of heart rate variability to the active orthostatic test in women
Resumo:
OBJECTIVES: The effects of the orthostatic test on the cardiovascular system have been investigated, but there are no data on the behavior of the geometric indices of heart rate variability. We evaluated the effects of the active orthostatic test on the geometric indices of heart rate variability in women. METHOD: The study was performed on 12 healthy women between ages 18 and 30. For the analysis of heart rate variability, heart rate was recorded beat-to-beat. The RR intervals were transformed into geometric figures, and from these we calculated the triangular index, the triangular interpolation of RR intervals, the SD1, SD2 indexes and the SD1/SD2 ratio, which were obtained from the Poincaré plot. Visual analysis of the plot was also performed. For the test, participants quickly stood up from a seated position in 3 seconds or less, and remained standing still for 15 minutes. Heart rate variability samples were collected at four moments: rest, 0-5 minutes, 5-10 minutes and 10-15 minutes at standing position. RESULTS: The triangular index, the triangular interpolation of RR intervals, the SD1 and SD2 indices were reduced (p < 0.05) at 10-15 minutes after the volunteers stood up from seated position. The SD1/SD2 ratio was decreased at 0-15 minutes after the subjects changed from seated to orthostatic position.