86 resultados para Diagnostic validity
Resumo:
The identification of appropriate laboratory measures to confirm clinical hypotheses is important in routine paracoccidioidomycosis medical care. The clinical records and laboratory reports of 401 paracoccidioidomycosis patients attended at the Tropical Diseases Area, Faculdade de Medicina de Botucatu, from 1974 to 2008 were reviewed. Direct mycological (DM), cell block (CB), histopathological (HP), and double immunodiffusion (DID) tests were evaluated before treatment. Typical Paracoccidioides brasiliensis yeast forms were observed in clinical specimens of 86% of the patients, but 14% were detected only by serological test. DM of 51 different tissue specimens produced 74.5% sensitivity, and 62.5% sensitivity was observed in 112 sputum samples. CB in 483 sputum samples generated 55.3% sensitivity. HP performed in 239 samples from different tissues revealed 96.7% sensitivity. Serology carried out in 351 patients and 200 healthy controls provided 90.0% sensitivity, 100.0% specificity, 100.0% positive predictive value, 85.1% negative predictive value and 93.6% accuracy. Comparisons of laboratory measurements performed in the same patient showed that sensitivity decreases from HP to DID to CB and DM, with the last two assays providing similar sensitivities. This study demonstrated that P. brasiliensis identification by HP, CB, and/or DM associated with DID is sufficient to establish the laboratorial diagnosis of paracoccidioidomycosis in practically all cases. (C) 2011 Royal Society of Tropical Medicine and Hygiene. Published by Elsevier Ltd. All rights reserved.
Resumo:
Tradicionalmente, os limites de tolerância biológica são utilizados exclusivamente para a promoção e a preservação da saúde dos trabalhadores, não sendo aplicados com fins diagnósticos. Entretanto, com relação a algumas intoxicações profissionais, o assunto é polêmico. Neste artigo, defende-se a utilização do limite de tolerância aplicado atualmente no Brasil à plumbemia como um critério importante para a realização do diagnóstico da intoxicação profissional pelo chumbo. Argumenta-se que, em oposição ao tradicional critério clínico, deve-se abordar o problema do diagnóstico da intoxicação pelo chumbo sob um ponto de vista epidemiológico, utilizando-se o atual valor do limite de tolerância para a plumbemia como um marcador de risco relativo significativamente aumentado.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The aim of this study was to evaluate the application of PCR technique for the detection of BoHV-5 in routinely formalin-fixed, paraffin-embedded brain tissues in 20 naturally infected calves affected by fatal meningoencephalitis. Brains were divided into two halves, one kept fresh for virus isolation and PCR assay, targeting the glycoprotein C gene from BoHV-5 genome. The other half brain, corresponding to posterior cortex region, was submitted to formalin fixation and embedded into paraffin blocks for microscopic evaluation and total DNA isolation. Most of the slides showed severe multifocal non-supurative encephalitis with neuronal degeneration, neurophagia, and no acidophilic intranuclear inclusions could be found in neurons and glial. The 20 fresh samples were confirmed, by virus isolation and PCR assay, as having the BoHV-5 virus and, respective glicoprotein C sequence, while 15 of 20 formalin-fixed, paraffin-embedded samples were considered positive for the same analysis. The results revealed the first description of PCR efficiency, applied to formalin-fixed, paraffin-embedded brain collected from naturally infected calves, improving the detection of BoHV-5 from archival samples in South America. (c) 2007 Published by Elsevier B.V.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The maximal lactate steady state (MLSS) is the highest blood lactate concentration that can be identified as maintaining a steady state during a prolonged submaximal constant workload. The objective of the present study was to analyze the influence of the aerobic capacity on the validity of anaerobic threshold (AT) to estimate the exercise intensity at MLSS (MLSS intensity) during cycling. Ten untrained males (UC) and 9 male endurance cyclists (EC) matched for age, weight and height performed one incremental maximal load test to determine AT and two to four 30-min constant submaximal load tests on a mechanically braked cycle ergometer to determine MLSS and MLSS intensity. AT was determined as the intensity corresponding to 3.5 mM blood lactate. MLSS intensity was defined as the highest workload at which blood lactate concentration did not increase by more than 1 mM between minutes 10 and 30 of the constant workload. MLSS intensity (EC = 282.1 ± 23.8 W; UC = 180.2 ± 24.5 W) and AT (EC = 274.8 ± 24.9 W; UC = 187.2 ± 28.0 W) were significantly higher in trained group. However, there was no significant difference in MLSS between EC (5.0 ± 1.2 mM) and UC (4.9 ± 1.7 mM). The MLSS intensity and AT were not different and significantly correlated in both groups (EC: r = 0.77; UC: r = 0.81). We conclude that MLSS and the validity of AT to estimate MLSS intensity during cycling, analyzed in a cross-sectional design (trained x sedentary), do not depend on the aerobic capacity.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
We reinvestigate the Bose-Einstein condensation (BEC) thermodynamics of a weakly interacting dilute Bose gas under the action of a trap using a semi-classical two-fluid mean-field model in order to find the domain of applicability of the model. Such a model is expected to break down once the condition of diluteness and weak interaction is violated. We find that this breakdown happens for values of coupling and density near the present experimental scenario of BEG. With the increase of the interaction coupling and density the model may lead to unphysical results for thermodynamic observables. (C) 2000 Published by Elsevier B.V. B.V, All rights reserved.
Resumo:
In a recent paper, we raised a question on the validity of Feynman's prescription of disregarding the Pauli principle in intermediate states of perturbation theory. In the preceding Comment, Cavalcanti correctly pointed out that Feynman's prescription is consistent with the exact solution of the model that we used. This means that the Pauli principle does not necessarily apply to intermediate states. We discuss implications of this puzzling aspect.
Resumo:
Regarding the Pauli principle in quantum field theory and in many-body quantum mechanics, Feynman advocated that Pauli's exclusion principle can be completely ignored in intermediate states of perturbation theory. He observed that all virtual processes (of the same order) that violate the Pauli principle cancel out. Feynman accordingly introduced a prescription, which is to disregard the Pauli principle in all intermediate processes. This ingenious trick is of crucial importance in the Feynman diagram technique. We show, however, an example in which Feynman's prescription fails. This casts doubts on the general validity of Feynman's prescription. [S1050-2947(99)04604-1].
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
A Nested-PCR (N-PCR) tem como objetivo melhorar a sensibilidade do diagnóstico direto da Pneumonia Enzoótica Suína, pois o isolamento do Mycoplasma hyopneumoniae é trabalhoso tornando-se inviável na rotina. Neste trabalho, foi realizado um projeto piloto para a otimização da técnica de N-PCR, utilizando três variáveis: tipo de amostra biológica, meio de transporte da amostra e método de extração do DNA, utilizando oito animais. Os resultados obtidos foram empregados no segundo experimento para a validação do teste utilizando 40 animais. Os resultados obtidos, pela otimização da N-PCR, neste trabalho, permite sugerir esta prova como método de diagnóstico de rotina no monitoramento das infecções por Mycoplasma hyopneumoniae em granjas de suínos.