49 resultados para Determination coefficients


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Pós-graduação em Agronomia (Irrigação e Drenagem) - FCA

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The aim of this work was the development a computer code for simulation and analysis of atomic spectra from databases constructed from the literature. There were created four routines that can be useful for spectroscopic studies in the atomic processes of laser isotope separation. In the first routine, Possible Transitions, the program checks the possible electron transitions from an energy level of the atom present in the database considering the selection rules for an electric dipole transition. The second routine, Locator Transitions, checks the possible electronic transitions within a user-specified spectral region. The routine Spectra Simulator creates simulated spectra using the graphical application gnuplot through lorentzian curve and finally, the routine Electronic Temperature determines the temperature of electronic excitation of the atom, thought the Boltzmann Plot Method. To test the reliability of the program there were obtained experimental emission spectra of a hollow cathode discharge of dysprosium and argon as a buffer gas. The hollow cathode discharge has been subjected to different values of operating currents and pressure of inert gas. The spectra obtained were treated with the assistance of program routines developed (Transition Locator and Spectra Simulator) and temperatures electronic excitation of the atoms of dysprosium in the different discharge conditions were calculated (routine Electronic Temperature). The results showed that the electronic excitation temperature of the neutral dysprosium atoms in the hollow cathode discharge increases with increasing current applied to the cathode and also by increasing the gas pressure buffer. The determination coefficients, R2, obtained by the Electronic Temperature routine using the linear adjust of the Boltzmann Plot Method were greater... (Complete abstract click electronic access below)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The main target here is to determine the orbit of an artificial satellite, using signals of the GPS constellation and least squares algorithms implemented through sequential Givens rotations as a method of estimation, with the aim of improving the performance of the orbit estimation process and, at the same time, minimizing the computational procedure cost. Geopotential perturbations up to high order and direct solar radiation pressure were taken into account. It was also considered the position of the GPS antenna on the satellite body that, lately, consists of the influence of the satellite attitude motion in the orbit determination process. An application has been done, using real data from the Topex/Poseidon satellite, whose ephemeris is available at Internet. The best accuracy obtained in position was smaller than 5 meters for short period (2 hours) and smaller than 28 meters for long period (24 hours) orbit determination. In both cases, the perturbations mentioned before were taken into consideration and the analysis occurred without selective availability on the signals measurements.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Simple and rapid procedures were developed for the quantification of amfepramone hydrochloride and diazepam and mazindol and diazepam in tablets using high performance liquid chromatography (HPLC) with UV detection. These techniques provided conditions for the separation of each active ingredient from the complex matrices of the dosage forms by dilution or extraction in methanol. Isocratic reversed phase chromatography was performed using acetonitrile, methanol, and aqueous 0,1% ammonium carbonate (70:10:20, v/v/v) as a mobile phase, Radial-Pak C-18 column (100 x 8 mm id, 4 mu m), a column temperature of 25+/-1 degrees C and detection at 255 nm. The calibration curves were linear over a wide concentration range (100-1000 mu g.mL(-1) to amfepramone hydrochloride and mazindol and 10-100 mu g.mL(-1) to diazepam) with good correlation factors of 0.9978, 0.9956 and 0.9997 for amfepramone hydrochloride, mazindol, and diazepam, respectively.Mean recoveries obtained from the two kinds of samples ranged from 83.2 to 102.5%, with coefficients of variation ranging from 1.0 to 6.1.These results demonstrated the efficiency of the proposed methods, as well as advantages such as simplicity and short duration of analysis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Several clean-up procedures which included the use of glass chromatography columns (silica gel, alumina, Florisil, silanized Celite-charcoal), Sep-Pak cartridges and standard solutions were compared for the determination of the following N-methylcarbamate (NMC) insecticides: aldicarb, carbaryl, carbofuran, methomyl and propoxur. According to recovery results of the compounds after elution in a glass column, the most efficient systems employed 4.6% deactivated alumina and a silanized Celite-charcoal (4:1) as adsorbents, using dichloromethane-methanol (99:1) and toluene-acetonitrile (75:25) mixtures, respectively, as binary eluents. The recoveries of the compounds studied varied from 84 to 120%. Comparable recoveries (75-100%) for Sep-Pak cartridges in normal phase (NH2, CN) and reversed phase (C-8) were observed. Different temperatures were tested during the concentration step in a rotary evaporator, and we verified a strong influence of this parameter on the stability of some compounds, such as carbofuran and carbaryl. Recovery studies employing the best clean up procedures were performed at the Brazilian agricultural level in potato and carrot samples; Validation methodology of the US Food and Drug Administration was adapted for the N-methylcarbamate analysis. Their recoveries ranged between 79 and 93% with coefficients of variation of 2.3-8%. (C) 1998 Elsevier B.V. B.V.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A simple and rapid method for the determination of 13 organophosphorus insecticides and their metabolites in olive oil by GC is described. The pesticide was extracted from oil with acetonitrile and no cleanup was needed. GC-nitrogen-phosphorus detection response factors of pesticides were affected by solvents and coextractive substances. Pesticides in hexane showed on average higher response factors. Standards were prepared in the residue-free oil extract solubilized in hexane to handle effects of matrix and solvent. The low amount of coextractive substances does not decrease the column efficiency, even after a few hundred analyses. Recovery at three fortification levels (ca. 0.1, 1.0 and 3.0 mg/kg) ranged from 74 to 118%, With coefficients of variation ranging from 1 to 16.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A simple and efficient method is described for the determination of fenpropathrin in oranges, pears, apples and strawberries. The procedure: is based on the extraction of each homogenized fruit sample with hexane:acetone (1:1, v/v) mixture, followed, by a cleanup technique on a column packed with florisil, using a hexane:ethyl ether (7:3, v/v) mixture, and gas chromatographic, analysis with electron capture detection (ECD). The fortification levels (0.5; 1.0; 2.0 mg kg(-1)) were selected according to the maximum residue limits (MRLs) established for fenpropathrin by Brazilian legislation. Mean recoveries from five replicates of fortified fruit samples ranged from 83 % to 98 %, with:coefficients of variation from 1.4 to 13.5 and detection limits varying from 0.1 to 0.2 mg kg(-1).