61 resultados para Detection specificity


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives:The aim of this in vitro study was to assess the inter- and intra-examiner reproducibility and the accuracy of the International Caries Detection and Assessment System-II (ICDAS-II) in detecting occlusal caries.Methods:One hundred and sixty-three molars were independently assessed twice by two experienced dentists using the 0- to 6-graded ICDAS-II. The teeth were histologically prepared and classified using two different histological systems [Ekstrand et al. (1997) Caries Research vol. 31, pp. 224-231; Lussi et al. (1999) Caries Research vol. 33, pp. 261-266] and assessed for caries extension. Sensitivity, specificity, accuracy and area under the ROC curve (A(z)) were obtained at D(2) and D(3) thresholds. Unweighted kappa coefficient was used to assess inter- and intra-examiner reproducibility.Results:For the Ekstrand et al. histological classification the sensitivity was 0.99 and 1.00, specificity 1.00 and 0.69 and accuracy 0.99 and 0.76 at D(2) and D(3), respectively. For the Lussi et al. histological classification the sensitivity was 0.91 and 0.75, specificity 0.47 and 0.62 and accuracy 0.86 and 0.68 at D(2) and D(3), respectively. The A(z) varied from 0.54 to 0.73. The inter- and intra-examiner kappa values were 0.51 and 0.58, respectively.Conclusions:ICDAS-II presented good reproducibility and accuracy in detecting occlusal caries, especially caries lesions in the outer half of the enamel.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: The purpose of this study was to assess the influence of cleaning pits and fissures with on aluminum oxide air abrasion system on the detection of occlusal caries in primary teeth using laser fluorescence (LF) and visual examination. Methods. The sample comprised 65 pit and fissure sites on extracted primary teeth suspected to be carious. The sites were submitted to 2 visual examinations (examiner JAR) and 2 LF readings (examiner TMV). Next, the occlusal surfaces were air-abraded and re-examined thereafter using both methods. The teeth were sectioned, and the histological analysis of the sites with a stereoscopic magnifying lens at X32 magnification was used as the gold standard Results. Cohen's kappa statistic for LF and visual examination were, respectively, 0.282/0.884 before and 0.896/0.905 after air abrasion. LF showed a sensitivity of 0.28 increasing to 0.49 and 0 specificity of 0.50 increasing to 0.92. Visual examination showed sensitivity of 0.78 and specificity of 0.73. Both increased after air abrasion. Conclusion: The findings suggest that cleaning pits and fissures with aluminum oxide air abrasion increased the accuracy of LF and visual examination for detection of occlusal caries in primary teeth.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective, the objective of this study was to evaluate the reliability of in vivo staining with toluidine blue in the detection of oral epithelial dysplasia, in situ carcinoma, and invasive squamous cell carcinomas in potentially malignant epithelial lesions (PMELs) and superficial oral ulcerations suggesting malignancy.Study design. Fifty patients with PMELs and superficial oral ulcerations suggestive of malignancy were selected from those treated at the Oral Medicine Service, Faculty of Dentistry, Araraquara, Brazil. All lesions were submitted to staining with an aqueous solution of 1% toluidine blue, followed by biopsy and histologic analysis. The sensitivity, specificity, and positive and negative predictive values were calculated.Results. Histologic diagnosis revealed that 14% of the lesions analyzed were in situ carcinoma and invasive squamous cell carcinomas, 12% were epithelial dysplasias, 13% were keratosis, 40% were lichen planus, and 8% were other benign lesions. The sensitivity uf the staining was 77%, the specificity 67%, and the positive and negative predictive values 43.5% and 88.9%, respectivelyConclusions, Staining with toluidine blue was demonstrated to be highly reliable in the detection of in situ carcinoma acid invasive squamous cell carcinoma, because false-negative results for the lesions did not occur. Toluidine blue staining is an adjunct to clinical judgment and not a substitute for either judgment or biopsy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: To evaluate the accuracy of Image Tool Software 3.0 (ITS 3.0) to detect marginal microleakage using the stereomicroscope as the validation criterion and ITS 3.0 as the tool under study.Materials and Methods: Class V cavities were prepared at the cementoenamel junction of 61 bovine incisors, and 53 halves of them were used. Using the stereomicroscope, microleakage was classified dichotomously: presence or absence. Next, ITS 3.0 was used to obtain measurements of the microleakage, so that 0.75 was taken as the cut-off point, and values equal to or greater than 0.75 indicated its presence, while values between 0.00 and 0.75 indicated its absence. Sensitivity and specificity were calculated by point and given as 95% confidence interval (95% CI).Results: The accuracy of the ITS 3.0 was verified with a sensitivity of 0.95 (95% CI: 0.89 to 1.00) and a specificity of 0.92 (95% CI: 0.84 to 0.99).Conclusion: Digital diagnosis of marginal microleakage using ITS 3.0 was sensitive and specific.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Oxacillin is the main drug of choice for the treatment of S. aureus infections. However, S. aureus resistance to oxacillin has become a major problem in the recent decades. The study aimed assess the rates of oxacillin resistance in S. aureus samples obtained at the Botucatu Medical School Hospital, UNESP, and to compare phenotypic techniques for the detection of MRSA against the gold standard method (mecA gene detection) in these samples. A total of 102 samples, previously isolated between 2002 and 2006, and kept at the Culture Collection of the Department of Microbiology and Immunology, in the Botucatu Biosciences Institute, UNESP, were included. Oxacillin resistance was assessed by oxacillin and cefoxitin disk diffusion and agar dilution tests, screening tests using Mueller-Hinton agar with 6 mu g/mL of oxacillin and 4% NaCl, E-test, and mecA gene detection. of the samples analyzed, 46 (45.1%) were mecA-positive. Oxacillin disk sensitivity and specificity were 86.9% and 91.1%, respectively. Cefoxitin disk sensitivity and specificity were respectively 91.3% and 91.1%. The screening test with the cefoxitin disk showed almost the same level of sensitivity (91.3%) and specificity (91.1%). With E-test strips, sensitivity was higher (97.8%) and specificity was comparable to that found with the other methods (91.1%). Ninety-three percent of the samples produced beta-lactamase and five of them were mecA-negative. There was a gradual increase in the number of oxacillin-resistant S. aureus samples between 2002 and 2004. However, from 2004 to 2006, the number of resistant samples dropped from 55% of MRSA in 2004, to 45% in 2005 and 34.6% in 2006. The data obtained reveal that, among phenotypic methods, the E-test yielded the best results, with higher sensitivity levels when compared to the other methods. The decreased resistance rate observed over the most recent years may be explained by the rational use of antimicrobial agents associated with good practices in the control of hospital infection, or may be related to the diminished use of oxacillin as a treatment option.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives: To evaluate the accuracy of three different cutoff points for the detection of high blood pressure in adolescents, given the strong relationship between overweight and high blood pressure levels.Methods: A total of 1,021 adolescents of both sexes were enrolled in the study, selected at random from public and private schools in Londrina, Brazil. Their body weight was measured using a digital balance, and their height with a portable stadiometer with a maximum extension of 2 meters. Arterial blood pressure was measured using an automatic apparatus. The capacity of body mass index to detect high blood pressure was gauged using ROC curves and their parameters (sensitivity, specificity, and area under the curve).Results: The cutoff points proposed in a Brazilian standard exhibited greater accuracy (males: 0.636 +/- 0.038; females: 0.585 +/- 0.043) than the cutoff points proposed in an international (males: 0.594 +/- 0.040; females: 0.570 +/- 0.044) and a North-American standard (males: 0.612 +/- 0.039; females: 0.578 +/- 0.044).Conclusions: The Brazilian proposal offered greatest accuracy for indicating high blood pressure levels.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The efficacy of fluorescence spectroscopy to detect squamous cell carcinoma is evaluated in an animal model following laser excitation at 442 and 532 nm. Lesions are chemically induced with a topical DMBA application at the left lateral tongue of Golden Syrian hamsters. The animals are investigated every 2 weeks after the 4th week of induction until a total of 26 weeks. The right lateral tongue of each animal is considered as a control site (normal contralateral tissue) and the induced lesions are analyzed as a set of points covering the entire clinically detectable area. Based on fluorescence spectral differences, four indices are determined to discriminate normal and carcinoma tissues, based on intraspectral analysis. The spectral data are also analyzed using a multivariate data analysis and the results are compared with histology as the diagnostic gold standard. The best result achieved is for blue excitation using the KNN (K-nearest neighbor, a interspectral analysis) algorithm with a sensitivity of 95.7% and a specificity of 91.6%. These high indices indicate that fluorescence spectroscopy may constitute a fast noninvasive auxiliary tool for diagnostic of cancer within the oral cavity. (C) 2008 Society of Photo-Optical Instrumentation Engineers.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A crude antigenic preparation of Babesia bigemina was used to develop an ELISA for the detection of IgM antibodies. Optimal dilutions of the antigen, using positive and negative reference sera, were determined by checkerboard titrations. Negative sera from cattle imported from tick-free areas, serum samples collected from infected B. bigemina cattle were used to validate the test. The specificity was 94% and sensitivity of the Elisa 87.5%. Sera from 385 cattle deriving from areas free from tick-borne diseases, which were submitted to a preimmunization process, were screened by this technique. The Elisa detected seroconversion on the 14th day post-inoculation in animals either infested with Boophilus microplus ticks (infected with B. bigemina), or inoculated with B. bigemina infected blood. Antibody titers decreased after day 33; however, all animals remained positive until the end of the experiment (124 days). The ELISA described may prove to be an appropriate serological test for the detection of IgM antibodies against B. bigemina.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Um ensaio de imunoadsorção enzimática (ELISA) baseado em antígeno bruto foi avaliado na detecção de anticorpos contra Babesia bigemina. A sensibilidade e a especificidade do teste foram de 98,0% e 99,0%, respectivamente. Concordando com a alta especificidade do teste, não foram verificadas reações cruzadas com soros de bezerros inoculados três vezes com 10(7) merozoítos de Babesia bovis. Com relação à comparação do ELISA com a imunofluorescência indireta (IFAT) na detecção de anticorpos contra B. bigemina em bezerros experimentalmente infectados com cinco isolados brasileiros geograficamente distintos deste hemoparasito, o IFAT foi capaz de detectar anticorpos um dia antes do ELISA na maioria dos soros dos animais. Houve uma boa concordância entre os resultados encontrados no ELISA e no IFAT com soros de bovinos de região de estabilidade enzoótica (k=0.61). No entanto, não houve concordância entre os testes sorológicos com soros de animais de área de instabilidade enzoótica (k=0.33). O ELISA foi empregado em um inquérito epidemiológico com 1.367 soros de quatro municípios do Pantanal de Mato Grosso do Sul e caracterizou esta região como uma área de estabilidade enzoótica, uma vez que as prevalências variaram de 87,7 a 98,9%. Dessa forma, este ELISA, que apresentou alta sensibilidade, especificidade e desempenho similar ao IFAT, pode ser utilizado no diagnóstico sorológico de B. bigemina.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Langmuir films of a tetracarboxylic perylene derivative and polypyrrole display condensed surface pressure isotherms that are shifted when Cu2+ ions are added to the ultrapure water subphase. These films were transferred onto interdigitated gold electrodes leading to Y-type Langmuir-Blodgett (LB) films. The electrodes modified with 5-layer LB films were immersed into a flask with ultrapure water and water containing Cu2+ ions at concentrations ranging from mM to muM. Impedance measurements indicated a distinct electrical response for the two types of films. Although the materials chosen have no specificity for ionic metals, they can be combined for detecting trace levels of Cu2+, which may be exploited in water quality monitoring. (C) 2004 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

1. Immunocytochemical procedures have played an increasingly larger role in the identification of infectious disease agents in tissue sections owing to the increased availability and specificity of antibody reagents, the great sensitivity of the methods, and the relative facility with which the studies are performed.2. Immunocytochemical methods can be applied to routine formalin-fixed tissue for the detection of infectious agents such as viruses, bacteria, fungi, and protozoa among other microorganisms for diagnostic and research purposes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Protein A containing Staphylococcus aureus was used to develop a coagglutination (COA) test for the detection and typing of foot and mouth disease virus (FMDV) O, A and C serotypes in infected cells and tissues. Different batches and amounts of guinea pig anti-FMDV sera were assessed to optimize the preparation of COA conjugates. The sensitivity and specificity of the COA Test for the detection of FMDV O, A and C serotypes and heterologous viruses was also characterized. Comparison between the COA Test and complement fixation test for the detection and typing of FMDV obtained from extracts of tongue epithelial tissues from infected cattle revealed high agreement in the results and indicated a potential application of the COA Test for the direct diagnosis of viruses.