20 resultados para Cumulative exergy analysis
Resumo:
In this paper, a methodology for the study of a fuel cell cogeneration system and applied to a university campus is developed. The cogeneration system consists of a molten carbonate fuel cell associated to an absorption refrigeration system. The electrical and cold-water demands of the campus are about 1,000 kW and 1,840 kW (at 7°C), respectively. The energy, exergy and economic analyses are presented. This system uses natural gas as the fuel and operates on electric parity. In conclusion, the fuel cell cogeneration system may have an excellent opportunity to strengthen the decentralized energy production in the Brazilian tertiary sector.
Resumo:
Aim: The aim of this study was to evaluate in situ, the early bacterial colonization on feldspar-ceramics submitted to different glazing. Methods and Materials: Fourteen standardized disc specimens (diameter: 5 mm, thickness: 1.5 mm) of each of two micro-particulate feldspathic ceramics (VM7 and VM13, Vita) were produced according to manufacturers' specifications for a total of 28 specimens (24 for the analysis of biofilm and 4 for topographic analysis analyzing the ceramic surfaces). Specimens from each type of ceramic were submitted to two different glazing methods composing four groups: VM7 glazed using glazing liquid Vita Akzent® 25 (G1) and glaze firing (G2), VM13 glazed using glazing liquid (G3) and glaze firing (G4). Six individuals (n=6) wore oral appliances with four ceramic specimens, fixed on the buccal face of the appliances. After 8 hours, each sample was evaluated for the presence (1) or absence (0) of bacterial colonization under a scanning electron microscope (SEM) on five randomly selected fields. The value for each sample was cumulative of the results observed in the fields. One sample from each group was evaluated under a SEM to verify the topographic pattern. Results: There was no difference with regard to bacterial colonization between the feldspar-ceramics and between the glazing types (Kruskal-Wallis non-parametric test). Conclusion: Feldspar-ceramics submitted to firing or glaze firing with Vita Akzent® 25 present a similar condition for in situ bacterial colonization. The similar topographic pattern of the ceramic surfaces seems to have influenced the bacterial colonization.
Resumo:
In this work, experimental results are reported for a small scale cogeneration plant for power and refrigeration purposes. The plant includes a natural gas microturbine and an ammonia/water absorption chiller fired by steam. The system was tested under different turbine loads, steam pressures and chiller outlet temperatures. An evaluation based on the 1st and 2nd Laws of Thermodynamics was also performed. For the ambient temperature around 24°C and microturbine at full load, the plant is able to provide 19 kW of saturated steam at 5.3 bar (161 °C), corresponding to 9.2 kW of refrigeration at -5 °C (COP = 0.44). From a 2nd law point-of-view, it was found that there is an optimal chiller outlet temperature that maximizes the chiller exergetic efficiency. As expected, the microturbine presented the highest irreversibilities, followed by the absorption chiller and the HRSG. In order to reduce the plant exergy destruction, it is recommended a new design for the HRSG and a new insulation for the exhaust pipe. © 2013 Elsevier Ltd. All rights reserved.
Resumo:
BACKGROUND AND OBJECTIVES: Gross motor (GM) deficits are often reported in children with prenatal alcohol exposure (PAE), but their prevalence and the domains affected are not clear. The objective of this review was to characterize GM impairment in children with a diagnosis of fetal alcohol spectrum disorder (FASD) or moderate to heavy maternal alcohol intake.METHODS: A systematic review with meta-analysis was conducted. Medline, Embase, Allied and Complementary Medicine Database, Cumulative Index to Nursing and Allied Health Literature, PsycINFO, PEDro, and Google Scholar databases were searched. Published observational studies including children aged 0 to <= 18 years with (1) an FASD diagnosis or moderate to heavy PAE, or a mother with confirmed alcohol dependency or binge drinking during pregnancy, and (2) GM outcomes obtained by using a standardized assessment tool. Data were extracted regarding participants, exposure, diagnosis, and outcomes by using a standardized protocol. Methodological quality was evaluated by using Strengthening the Reporting of Observational Studies in Epidemiology guidelines.RESULTS: The search recovered 2881 articles of which 14 met the systematic review inclusion criteria. The subjects' mean age ranged from 3 days to 13 years. Study limitations included failure to report cutoffs for impairment, nonstandardized reporting of PAE, and small sample sizes. The meta-analysis pooled results (n = 10) revealed a significant association between a diagnosis of FASD or moderate to heavy PAE and GM impairment (odds ratio: 2.9; 95% confidence interval: 2.1-4.0). GM deficits were found in balance, coordination, and ball skills. There was insufficient data to determine prevalence.CONCLUSIONS: The significant results suggest evaluation of GM proficiency should be a standard component of multidisciplinary FASD diagnostic services.
Resumo:
This study aimed to evaluate the sediment quality in the estuarine protected area known as Canan,ia-Iguape-Peruibe (CIP-PA), located on the southeastern coast of Brazil. The study was designed considering possible negative effects induced by the city of Canan,ia on the sediment quality of surrounding areas. This evaluation was performed using chemical and ecotoxicological analyses. Sediments were predominantly sandy, with low CaCO3 contents. Amounts of organic matter varied, but higher contents occurred closer to the city, as well as did Fe and Total Recoverable Oils and Greases (TROGs) concentrations. Contamination by Cd and Cu was revealed in some samples, while concentrations of Zn were considered low. Chronic toxicity was detected in all tested sediments and acute toxicity occurred only in sediments collected near the city. The principal component analysis (PCA) revealed an association among Cd, Cu, Fe, TROG, fines, organic matter, CaCO3, and chronic toxicity, whereas acute toxicity was found to be associated with Zn and mud. However, because Zn levels were low, acute toxicity was likely due to a contaminant that was not measured. Results show that there is a broad area within the CIP-PA that is under the influence of mining activities (chronic toxicity, moderate contamination by metals), whereas poorer conditions occur closer to Canan,ia (acute toxicity); thus, the urban area seems to constitute a relevant source of contaminants for the estuarine complex. These results show that contamination is already capable of producing risks for the local aquatic biota, which suggests that the CIP-PA effectiveness in protecting estuarine biota may be threatened.