65 resultados para Conservation Area Networks
Resumo:
This paper presents a mixed-integer linear programming model to solve the conductor size selection and reconductoring problem in radial distribution systems. In the proposed model, the steady-state operation of the radial distribution system is modeled through linear expressions. The use of a mixed-integer linear model guarantees convergence to optimality using existing optimization software. The proposed model and a heuristic are used to obtain the Pareto front of the conductor size selection and reconductoring problem considering two different objective functions. The results of one test system and two real distribution systems are presented in order to show the accuracy as well as the efficiency of the proposed solution technique. © 1969-2012 IEEE.
Resumo:
This paper presents a mixed-integer linear programming model to solve the problem of allocating voltage regulators and fixed or switched capacitors (VRCs) in radial distribution systems. The use of a mixed-integer linear model guarantees convergence to optimality using existing optimization software. In the proposed model, the steady-state operation of the radial distribution system is modeled through linear expressions. The results of one test system and one real distribution system are presented in order to show the accuracy as well as the efficiency of the proposed solution technique. An heuristic to obtain the Pareto front for the multiobjective VRCs allocation problem is also presented. © 2012 Elsevier Ltd. All rights reserved.
Resumo:
Traditionally, ancillary services are supplied by large conventional generators. However, with the huge penetration of distributed generators (DGs) as a result of the growing interest in satisfying energy requirements, and considering the benefits that they can bring along to the electrical system and to the environment, it appears reasonable to assume that ancillary services could also be provided by DGs in an economical and efficient way. In this paper, a settlement procedure for a reactive power market for DGs in distribution systems is proposed. Attention is directed to wind turbines connected to the network through synchronous generators with permanent magnets and doubly-fed induction generators. The generation uncertainty of this kind of DG is reduced by running a multi-objective optimization algorithm in multiple probabilistic scenarios through the Monte Carlo method and by representing the active power generated by the DGs through Markov models. The objectives to be minimized are the payments of the distribution system operator to the DGs for reactive power, the curtailment of transactions committed in an active power market previously settled, the losses in the lines of the network, and a voltage profile index. The proposed methodology was tested using a modified IEEE 37-bus distribution test system. © 1969-2012 IEEE.
Resumo:
In this work, a mathematical model to analyze the impact of the installation and operation of dispersed generation units in power distribution systems is proposed. The main focus is to determine the trade-off between the reliability and operational costs of distribution networks when the operation of isolated areas is allowed. In order to increase the system operator revenue, an optimal power flow makes use of the different energy prices offered by the dispersed generation connected to the grid. Simultaneously, the type and location of the protective devices initially installed on the protection system are reconfigured in order to minimize the interruption and expenditure of adjusting the protection system to conditions imposed by the operation of dispersed units. The interruption cost regards the unsupplied energy to customers in secure systems but affected by the normal tripping of protective devices. Therefore, the tripping of fuses, reclosers, and overcurrent relays aims to protect the system against both temporary and permanent fault types. Additionally, in order to reduce the average duration of the system interruption experienced by customers, the isolated operation of dispersed generation is allowed by installing directional overcurrent relays with synchronized reclose capabilities. A 135-bus real distribution system is used in order to show the advantages of using the mathematical model proposed. © 1969-2012 IEEE.
Resumo:
This paper presents a mixed-integer linear programming approach to solving the problem of optimal type, size and allocation of distributed generators (DGs) in radial distribution systems. In the proposed formulation, (a) the steady-state operation of the radial distribution system, considering different load levels, is modeled through linear expressions; (b) different types of DGs are represented by their capability curves; (c) the short-circuit current capacity of the circuits is modeled through linear expressions; and (d) different topologies of the radial distribution system are considered. The objective function minimizes the annualized investment and operation costs. The use of a mixed-integer linear formulation guarantees convergence to optimality using existing optimization software. The results of one test system are presented in order to show the accuracy as well as the efficiency of the proposed solution technique.© 2012 Elsevier B.V. All rights reserved.
Resumo:
This paper presents a methodology for modeling high intensity discharge lamps based on artificial neural networks. The methodology provides a model which is able to represent the device operating in the frequency of distribution systems, facing events related to power quality. With the aid of a data acquisition system to monitor the laboratory experiment, and using $$\text{ MATLAB }^{\textregistered }$$ software, data was obtained for the training of two neural networks. These neural networks, working together, were able to represent with high fidelity the behavior of a discharge lamp. The excellent performance obtained by these models allowed the simulation of a group of lamps in a distribution system with shorter simulation time when compared to mathematical models. This fact justified the application of this family of loads in electric power systems. The representation of the device facing power quality disturbances also proved to be a useful tool for more complex studies in distribution systems. © 2013 Brazilian Society for Automatics - SBA.
Resumo:
Pós-graduação em Agronomia (Irrigação e Drenagem) - FCA
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Pós-graduação em Geociências e Meio Ambiente - IGCE
Resumo:
The objective of this research was to conduct an analysis of multitemporal landscape Ipanema National Forest, located in the municipalities of Iperó, Capela do Alto and Araçoiaba da Serra – São Paulo estate, Brazil, considering the scenarios of 1965, 2007 and 2011. The multitemporal analysis, using aerial photographs and satellite images, contributed to the contextualization and spatialization of the evolution of the landscape area. Through analysis interpretation of the images, performed by means of supervised classification were obtained thematic maps of the area, equivalent to approximately 53 km2. Through geoprocessing techniques, especially Geographic Information Systems, it was possible the integration and manipulation of data, both spatial and statistical, allowing integrated analysis of data from the entire area of the National Forest of Ipanema. As the main result, we found that the Ipanema National Forest is in landscape evolution positive, with those 46 years examined the increase of native heavy foliage areas. Increasing from 7.1 km2 of the total area of dense vegetation in 1965 to 35.9 km2 in 2011. Overall, it was possible to realize a scenario landscape quite optimistic about the evolution of forest conservation area
Resumo:
This study aims to identify the environmental and social elements that should underpin the creation of a Municipal Natural Park in accordance with Law 9985/2000, establishing the SISTEMA NACIONAL DE UNIDADES DE CONSERVAÇÃO ( SNUC ) . The northeast sector of the city of Rio Claro - SP , envolving, among others , the neighborhood Mãe Preta, the most significant of the site is consolidated as an area of significant environmental value for the consolidation of a conservation area . The proposed establishment of this unit has been discussed since the beginning of this year by Secretaria Municipal de Planejamento, Desenvolvimento e Meio Ambiente de Rio Claro- SP (SEPLADEMA ) and meets the Municipal Director Plan that provides for the establishment of several protected areas in the City . The study area suffers severe pressure due to peripheral urbanization and characterized environmental fragility according to numerous studies by researchers at UNESP, Rio Claro - SP and research in situ. Stand out in soils susceptible to sheet erosion area, the presence of a large proportion of gully area subject to flooding and significant breeding capitation water for public supply
Resumo:
Pós-graduação em Engenharia Elétrica - FEIS
Resumo:
Pós-graduação em Agronomia (Irrigação e Drenagem) - FCA
Resumo:
Within the current context of environmental degradation, primarily caused by unsustainable pat terns of production and consumption (AGENDA 21, 1992), the Protected Areas (PAs) are considered internationally as one of the most successful measures for the conservat ion of biodiversity, according to the Union for the Conservation of Nature (IUCN). The city of Rio Claro (Sao Paulo, Brazi l ) has a significant conservation area in both environmental aspects as historical and cultural, the State Forest 'Edmundo Navarro de Andrade' (FEENA). Beyond the conservation measures, there is a need to develop environmental education that encourages community participation and appreciation in the unit 's maintenance and protection, as well as provide moments of reflection that could conduct perceptual changes, behavioral, attitudinal and evaluative on relations between human beings and their environment . This work brings the proposal to create an interpretive trail in the area of public use of FEENA to contribute to the Unit Management Plan in order to make it an Environmental Education tool. To prepare the planning of the interpretive trail, a deep bibliographic and cartographic review was performed on the subject. It was applied questionnaires in order to know the visitors better and map the features of public visitation, as well as map the visitor preferences about how they would like to receive information on the area and expose field studies in the track site. The trail was traced taking into account the environmental and social aspects, we propose a track suspended above the ground, in order to affect as little as possible and to include the area in the context of PAs people with reduced mobility and visually impaired
Resumo:
Pós-graduação em Geociências e Meio Ambiente - IGCE