38 resultados para Cervical region
Resumo:
This study measured the critical temperature reaching time and also the variation of temperature in the surface of the cervical region and within the pulp chamber of human teeth submitted to dental bleaching using 35% hydrogen peroxide gel activated by three different light sources. The samples were randomly divided into 3 groups (n = 15), according to the catalyst light source: Halogen Light (HL), High Intensity Diode Laser (DL), and Light Emmited Diode (LED). The results of temperature variation were submitted to the analysis of variance and Tukey test with p < 0.05. The temperature increase (mean value and standard deviation) inside the pulp chamber for the HL group was 6.8 ± 2.8°C; for the DL group was 15.3 ± 8.8°C; and for the LED group was 1.9 ± 1.0°C for. The temperature variation (mean value and standard deviation) on the tooth surface, for the group irradiated with HL was 9.1 ± 2.2°C; for the group irradiated with DL were 25.7 ± 18.9°C; and for the group irradiated with LED were 2.6 ± 1.4°C. The mean temperature increase values were significantly higher for the group irradiated with DL when compared with groups irradiated with HL and LED (p < 0.05). When applying the inferior limits of the interval of confidence of 95%, an application time of 38.7 s was found for HL group, and 4.4 s for DL group. The LED group did not achieve the critical temperatures for pulp or the periodontal, even when irradiated for 360 s. The HL and DL light sources may be used for dental bleaching for a short period of time. The LED source did not heat the target tissues significantly within the parameters used in this study. © 2010 Pleiades Publishing, Ltd.
Resumo:
The cephalalgias are frequently associated with the temporomandibular disorders being common to find an increase of pain sensitivity in these patients. Thus, the objective of present study was to assess the sensitivity to palpation in patients presenting with chronic temporomandibular disorders comparing two groups one with headache and other without it, respectively. The temporomandibular disorders and the primary cephalalgias were diagnosed according the Diagnostic Criteria for the Research of Temporomandibular Disorders and by a questionnaire based on the International Classification of the Cephalalgias (2004). Location, assessment and grouping of muscular and articular areas for palpation were carried out according to the Diagnostic Criteria for above mentioned disorders, considering bilaterally the masseter muscle, the temporalis muscle, the cervical region and the temporomandibular joint. Sample included 213 (88.0 %) of women and 29 (12.0 %) men with a mean age of 37.41 years. The mean of number of zones positive to palpation in the groups without headaches, tension headache, migraine and daily chronic headache were: 12.43, 14.38, 15.21 and 15.62 (p= 0.107) (min 2 max 22). The areas of temporalis muscle showed significant differences among groups (p= 0.007). The number of painful points was not statistically different among groups and only in the temporalis muscle there were differences with statistical significant to palpation.
Resumo:
Objectives: This study evaluated the reliability and failure modes of implants with a microthreaded or smooth design at the crestal region, restored with screwed or cemented crowns. The postulated null hypothesis was that the presence of microthreads in the implant cervical region would not result in different reliability and strength to failure than smooth design, regardless of fixation method, when subjected to step-stress accelerated life-testing (SSALT) in water. Materials and methods: Eighty four dental implants (3.3 × 10 mm) were divided into four groups (n = 21) according to implant macrogeometric design at the crestal region and crown fixation method: Microthreads Screwed (MS); Smooth Screwed (SS); Microthreads Cemented (MC), and Smooth Cemented (SC). The abutments were torqued to the implants and standardized maxillary central incisor metallic crowns were cemented (MC, SC) or screwed (MS, SS) and subjected to SSALT in water. The probability of failure versus cycles (90% two-sided confidence intervals) was calculated and plotted using a power law relationship for damage accumulation. Reliability for a mission of 50,000 cycles at 150 N (90% 2-sided confidence intervals) was calculated. Differences between final failure loads during fatigue for each group were assessed by Kruskal-Wallis along with Benferroni's post hoc tests. Polarized-light and scanning electron microscopes were used for failure analyses. Results: The Beta (β) value (confidence interval range) derived from use level probability Weibull calculation of 1.30 (0.76-2.22), 1.17 (0.70-1.96), 1.12 (0.71-1.76), and 0.52 (0.30-0.89) for groups MC, SC, MS, and SS respectively, indicated that fatigue was an accelerating factor for all groups, except for SS. The calculated reliability was higher for SC (99%) compared to MC (87%). No difference was observed between screwed restorations (MS - 29%, SS - 43%). Failure involved abutment screw fracture for all groups. The cemented groups (MC, SC) presented more abutment and implant fractures. Significantly higher load to fracture values were observed for SC and MC relative to MS and SS (P < 0.001). Conclusion: Since reliability and strength to failure was higher for SC than for MC, our postulated null hypothesis was rejected. © 2012 John Wiley & Sons A/S.
Resumo:
The aim of this study was to evaluate the stress distribution in implants of regular platforms and of wide diameter with different sizes of hexagon by the 3-dimensional finite element method. We used simulated 3-dimensional models with the aid of Solidworks 2006 and Rhinoceros 4.0 software for the design of the implant and abutment and the InVesalius software for the design of the bone. Each model represented a block of bone from the mandibular molar region with an implant 10 mm in length and different diameters. Model A was an implant 3.75 mm/regular hexagon, model B was an implant 5.00 mm/regular hexagon, and model C was an implant 5.00 mm/ expanded hexagon. A load of 200 N was applied in the axial, lateral, and oblique directions. At implant, applying the load (axial, lateral, and oblique), the 3 models presented stress concentration at the threads in the cervical and middle regions, and the stress was higher for model A. At the abutment, models A and B showed a similar stress distribution, concentrated at the cervical and middle third; model C showed the highest stresses. On the cortical bone, the stress was concentrated at the cervical region for the 3 models and was higher for model A. In the trabecular bone, the stresses were less intense and concentrated around the implant body, and were more intense for model A. Among the models of wide diameter (models B and C), model B (implant 5.00 mm/regular hexagon) was more favorable with regard to distribution of stresses. Model A (implant 3.75 mm/regular hexagon) showed the largest areas and the most intense stress, and model B (implant 5.00 mm/regular hexagon) showed a more favorable stress distribution. The highest stresses were observed in the application of lateral load.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Odontologia Restauradora - ICT
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The sonographic evaluation of thyroid glands in veterinary medicine presents challenges due to the complexity of the anatomical region, professional experience and type of ultrasonography equipment. The technique is considered a versatile diagnostic method that is noninvasive and has a low cost indicated in different clinical situations. Thyroid carcinoma is a malignant tumor that is often invasive and frequently metastatic to regional lymph nodes and lungs. The prognostic indicators for survival after surgery include tumor size, histological type, mobility and presence or absence of metastasis. The objective of the present report is to demonstrate the importance of ultrasound as a complementary method in the evaluation of thyroid carcinoma in dogs. At the Dr. Halim Atique Veterinary Hospital, an eight-year-old male Pit Bull was examined due to a history of firm painless swelling, approximately six inches in diameter, in the ventral cervical region, for about two months. The sonogram showed a nodular area, with defined and regular margins, and heterogeneous hypoechoic parenchyma, with areas of cavitation and swelling of the thyroid. Histopathology of the nodule was consistent with carcinoma. After thyreoidectomy and hormone replacemet, the patient is in good clinical condition.
Resumo:
Pós-graduação em Design - FAAC
Resumo:
The cosmopolitan beetles of the Paederus genus (potos) cause a severe dermatitis when the insect is crushed against the skin of exposed areas (the cervical region is the most affected). Toxins (pederin and others) from the hemolymph of the insect cause plaques and/or bizarre, linear lesions with erythema, edema, blisters, pustules, crusts and exulcerations. There may be a burning sensation and severe conjunctivitis. Lesions disappear after 10 days and may leave hyperchromic macules. Treatment is made with topical corticosteroids and intensive washing.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Descreveu-se a anatomia da região cervical de equinos adultos, com base em imagens obtidas no exame de tomografia computadorizada helicoidal realizado em peças anatômicas de equinos adultos. A tomografia computadorizada foi o método de imagem diagnóstica de escolha e possibilita as reconstruções de imagens tridimensionais e em outros planos anatômicos, como sagital e coronal. Todas as imagens foram adquiridas e avaliadas em filtro e janela para tecido ósseo. Observaram-se diferenças anatômicas e as particularidades normais das vértebras, principalmente da região occipitoatlantoaxial, a qual apresenta maior incidência de alterações.
Resumo:
Objectives: This study evaluated the bond strength of luting systems for bonding glass fiber posts to root canal dentin. The hypothesis tested was that there are no differences in bond strength of glass fiber posts luted with different cement systems.Methods: Forty bovine incisors were randomly assigned to five different resin cement groups (n=8). After endodontic treatment and crown removal, translucent glass fiber posts were bonded into the root canal using five different luting protocols (self-cured cement and etch-and-rinse adhesive system; dual-cured cement and etch-and-rinse adhesive system; self-cured cement and self-etch adhesive system; dual-cured cement and self-etch adhesive system; and dual-cured self-adhesive cement). Push-out bond strength was evaluated at three different radicular levels: cervical, middle, and apical. The interface between resinous cement and the post was observed using a stereoscopic microscope.Results: Analysis of variance showed a statistically significant difference among the cements (p<0.05) and the root canal thirds (p<0.05). The self-adhesive resinous cement had lower values of retention.Conclusions: The resin cements used with etch-and-rinse and self-etch adhesive systems seem to be adequate for glass fiber post cementation.