31 resultados para Caries detection
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The aim of this study was to compare the in situ and in vitro performances of a laser fluorescence (LF) device (DIAGNOdent 2095) with visual inspection for the detection of occlusal caries in permanent teeth. Sixty-four sites were selected, and visual inspection and LF assessments were carried out, in vitro, three times by two independent examiners, with a 1-week interval between evaluations. Afterwards, the occlusal surfaces were mounted on the palatal portion of removable acrylic orthodontic appliances and placed in six volunteers. Assessments were repeated and validated by histological analysis of the tooth sections under a stereomicroscope. For both examiners, the highest intra-examiner values were observed for the visual inspection when in vitro and in situ evaluations were compared. The inter-examiner reproducibility varied from 0.61 to 0.64, except for the in vitro assessment using LF, which presented a lower value (0.43). The methods showed high specificity at the D(1) threshold (considering enamel and dentin caries as disease). In vitro evaluations showed the highest values of sensitivity for both methods when compared to the in situ evaluations at D(1) and D(2) (considering only dentinal caries as the disease) thresholds. For both methods, the results of sensitivity (at D(1) and D(2)) and accuracy (at D(1)) showed significant differences between in vitro and in situ conditions. However, the sensitivity (at D(1) and D(2)), specificity and accuracy (both at D(1)) of the methods were not significantly different when the same condition was considered. It can be concluded that visual inspection and LF showed better performance in vitro than in situ.
Resumo:
The aim of this in vitro study was to assess the influence of varying examiner's clinical experience on the reproducibility and accuracy of radiographic examination for occlusal caries detection. Standardized bitewing radiographs were obtained from 166 permanent molars. Radiographic examination was performed by final-year dental students from two universities (A, n=5; B, n=5) and by dentists with 5 to 7 years of experience who work in two different countries (C, n=5; D, n=5). All examinations were repeated after 1-week interval. The teeth were histologically prepared and assessed for caries extension. For intraexaminer reproducibility, the unweighted kappa values were: A (0.11-0.40), B (0.12-0.33), C (0.47-0.58), and D (0.42-0.71). Interexaminer reproducibility statistics were computed based on means +/- SD of unweighted kappa values: A (0.07 +/- 0.05), B (0.12 +/- 0.09), C (0.24 +/- 0.08), and D (0.33 +/- 0.10). Sensitivity, specificity, and accuracy were calculated at D(1) and D(3) thresholds and compared by performing McNemar test (p=0.05). D(1) sensitivity ranged between 0.29 and 0.75 and specificity between 0.24 and 0.85. D(3) specificity was moderate to high (between 0.62 and 0.95) for all groups, with statistically significant difference between the dentists groups (C and D). Sensitivity was low to moderate (between 0.21 and 0.57) with statistically significant difference for groups B and D. Accuracy was similar for all groups (0.55). Spearman's correlations were: A (0.12), B (0.24), C (0.30), and D (0.38). In conclusion, the reproducibility of radiographic examination was influenced by the examiner's clinical experience, training, and dental education as well as the accuracy in detecting occlusal caries.
Resumo:
The aim of this in vitro study was to evaluate the relationship between laser fluorescence values and sealant penetration depth on occlusal fissures. One hundred and sixty-six permanent molars were selected and divided into four groups, which were each treated using a different sealant (two clear and two opaque). The teeth were independently measured twice by two experienced dentists using two laser fluorescence devices-DIAGNOdent (LF and LFpen)-before and after sealing, and then thermoclycled. After measuring, the teeth were histologically prepared and assessed for caries extension. Digital photographs of the cut sealed sites were assessed, and the sealant penetration depth was measured. All 166 sites were measured by one of the examiners taking as limits the outer and inner surface of the sealant into the fissure. For each device (LF and LFpen) and each group, the difference between the values at baseline and after sealing was plotted against the sealant penetration depth and scatter plots were provided. It could be observed that most of the points were concentrated around the zero line, for both LF and LFpen in the four groups. In conclusion, there is no relation between changes in DIAGNOdent values and increasing of depth sealant penetration within the occlusal fissures.
Resumo:
This study compared the performance of fluorescence-based methods, radiographic examination, and International Caries Detection and Assessment System (ICDAS) II on occlusal surfaces. One hundred and nineteen permanent human molars were assessed twice by 2 experienced dentists using the laser fluorescence (LF and LFpen) and fluorescence camera (FC) devices, ICDAS II and bitewing radiographs (BW). After measuring, the teeth were histologically prepared and assessed for caries extension. The sensitivities for dentine caries detection were 0.86 (FC), 0.78 (LFpen), 0.73 (ICDAS II), 0.51 (LF) and 0.34 (BW). The specificities were 0.97 (BW), 0.89 (LF), 0.65 (ICDAS II), 0.63 (FC) and 0.56 (LFpen). BW presented the highest values of likelihood ratio (LR)+ (12.47) and LR- (0.68). Rank correlations with histology were 0.53 (LF), 0.52 (LFpen), 0.41 (FC), 0.59 (ICDAS II) and 0.57 (BW). The area under the ROC curve varied from 0.72 to 0.83. Inter- and intraexaminer intraclass correlation values were respectively 0.90 and 0.85 (LF), 0.93 and 0.87 (LFpen) and 0.85 and 0.76 (FC). The ICDAS II kappa values were 0.51 (interexaminer) and 0.61 (intraexaminer). The BW kappa values were 0.50 (interexaminer) and 0.62 (intraexaminer). The Bland and Altman limits of agreement were 46.0 and 38.2 (LF), 55.6 and 40.0 (LFpen) and 1.12 and 0.80 (FC), for intra- and interexaminer reproducibilities. The posttest probability for dentine caries detection was high for BW and LF. In conclusion, LFpen, FC and ICDAS II presented better sensitivity and LF and BW better specificity. ICDAS II combined with BW showed the best performance and is the best combination for detecting caries on occlusal surfaces. Copyright (C) 2008 S. Karger AG, Basel.
Resumo:
This in vitro study evaluated the performance of visual (International Caries Detection and Assessment System [ICDAS]) and radiographic (bitewing [BW]) examinations for occlusal caries detection and their associations with treatment decision (TD). Permanent teeth (n=104) with occlusal surfaces varying from sound to cavitated were selected. Sites were identified from 10x occlusal surface photographs. Standardized bitewing (BW) radiographs were taken. Four dentists with at least five years of experience scored all teeth twice (one-week interval) for ICDAS (0-6), BW (0=sound, 1=caries restricted to enamel, 2=caries in outer third dentin, 3=caries in inner third dentin), and TD (0=no treatment, 1=sealant, 2=microabrasion and sealant, 3=round bur sealant, 4a=resin, 4b=amalgam). Histological validation was performed by observation under a light microscope, with lesions classified on a five-point scale. Intraexaminer and inter-examiner repeatability were assessed using two-way tables and intraclass correlation coefficients (ICCs). Comparisons between percentage correct, specificity, sensitivity, and area under the receiver-operating characteristic (ROC) curve were performed using bootstrap analyses. ICCs for intraexaminer and interexaminer repeatability indicated good repeatability for each examiner, ranging from 0.78 to 0.88, and among examiners, ranging from 0.74 to 0.81. Correlation between ICDAS and TD was 0.85 and between BW and TD was 0.78. Correlation between the methods and histological scores was moderate (0.63 for ICDAS and 0.61 for BW). The area under the ROC curve was significantly greater for ICDAS than for BW (p<0.0001). ICDAS had significantly lower specificity than BW did (p=0.0269, 79% vs 94%); however, sensitivity was much higher for ICDAS than for BW (p<0.0001, 83% vs 44%). Data from this investigation suggested that the visual examination (ICDAS) showed better performance than radiographic examination for occlusal caries detection. The ICDAS was strongly associated with TD. Although the correlation between the ICDAS and BW was lower, it is still valuable in the clinical decision-making process.
Resumo:
Pós-graduação em Ciências Odontológicas - FOAR
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
The aim of this clinical study was to evaluate and compare the performance of visual exam with use of the Nyvad criteria (visual examination - (VE)), interproximal radiography (BW), laser fluorescence device (DIAGNOdent Pen-DDPen), and their association in the diagnosis of proximal lesions in primary teeth. For this purpose, 45 children (n = 59 surfaces) of both sexes, aged between 5 and 9 years were selected, who presented healthy primary molars or primary molars with signs suggestive of the presence of caries lesions. The surfaces were clinically evaluated and coded according to the Nyvad criteria and immediately afterwards with the DDPen. Radiographic exam was performed only on the surfaces coded with Nyvad scores 2, 3, 5, or 6. Active caries lesions and/or those with discontinuous surfaces were restored, considering the depth of lesion as reference standard. Sensitivity, specificity, accuracy, and area under ROC curve were calculated for each technique and its associations. Visual exam with Nyvad criteria presented the highest specificity, accuracy, and area under ROC curve values. The DDPen presented the highest sensitivity values. Association with one or more methods resulted in an increase in specificity. The performance of visual, radiographic, and DDpen exams and their associations were good; however, the clinical examination with the Nyvad criteria was sufficient for the diagnosis of interproximal lesions in primary teeth.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
There are several methods for identifying carious dentinal tissue aiming to avoid removal of healthy dentinal tissue. Objectives: The purpose of this study was to test different methods for the detection of carious dentinal tissue regarding the amount of carious tissue removed and the remaining dentin microhardness after caries removal. Material and methods: The dentin surfaces of 20 bovine teeth were exposed and half of the surface was protected with nail polish. Cariogenic challenge was performed by immersion in a demineralizing solution for 14 days. After transverse cross-section of the crown, the specimens were divided into four groups (n=10), according to the method used to identify and remove the carious tissue: "Papacarie", Caries-detector dye, DIAGNOdent and Tactile method. After caries removal, the cross-sectional surface was included in acrylic resin and polished. In a microhardness tester, the removed dentin thickness and the Vickers microhardness of the following regions were evaluated: remaining dentin after caries removal and superficial and deep healthy dentin. Results: ANOVA and Tukey's test (alpha=0.05) were performed, except for DIAGNOdent, which did not detect the presence of caries. Results for removed dentin thickness were: "Papacarie" (424.7 +/- 105.0; a), Caries-detector dye (370.5 +/- 78.3; ab), Tactile method (322.8 +/- 51.5; bc). Results for the remaining dentin microhardness were: "Papacarie" (42.2 +/- 10.5; bc), Caries-detector dye (44.6 +/- 11.8; bc), Tactile method (24.3 +/- 9.0; d). Conclusions: DIAGNOdent did not detect the presence of carious tissue; Tactile method and "Papacarie" resulted in the least and the most dentinal thickness removal, respectively; Tactile method differed significantly from "Papacarie" and Caries-detector dye in terms of the remaining dentin microhardness, and Tactile method was the one which presented the lowest microhardness values.
Resumo:
This study aimed to determine the lag time between increased fluoride (F) intake and F detection in human nails, as well as the influence of nails growth rate and length on this. Ten 20- to 35-year-old volunteers received 1.8 mg F daily, for 30 days. Nail growth rate and length were determined for all fingernails and toenails. Nail samples were collected at the beginning of the study and every 2 weeks (15 collections in all) and F concentrations were determined. The growth rate was statistically higher in fingernails than in toenails. No statistically significant differences were observed between right and left sides. Growth rate was significantly greater for big toenails than for the other toenails, but this pattern was not found for fingernails. The estimated mean lag times for F detection in fingernails and toenails were 101 and 123 days, respectively. An apparent increase in fingernail F concentrations was observed 84 days after the beginning of the study, although this was not statistically different from baseline. For toenails, statistically significant increases in F concentration in relation to baseline were observed 112 and 140 days after increased F ingestion. These increases occurred within the 95% confidence intervals for the calculated mean lag time for fluoride detection in nails. Considering the large amount of sample provided by the big toenails, together with their faster growth rate, as well as the fact that toenails are less prone to environmental contamination, our data suggest that big toenails are more suitable biomarkers of fluoride intake.
Resumo:
Objective: The aim of the present study was to identify the free amino acid content in whole saliva of children with (CE) and without early childhood caries (CF) (ECC), correlating these findings with caries experience and mutans streptococci (MS) levels in saliva.Design: Seventy-eight healthy children, both genders, 6-71 months age, were selected to participate in the study. Following examination for dmft scores calculation, unstimulated whole saliva was collected from all 78 participants, stored at -80 degrees C, and used for amino acid analysis, on a Biochem 20 plus amino acid analyzer. Stimulated whole saliva was collected from 52 children, transported, diluted and plated on MSB agar medium for detection of MS in cfu/mL.Results: Forty different free amino acids were identified in whole saliva, with great variation in their concentration. A statistically significant relation was found between caries experience and the presence of free proline and glycine. While proline (p = 0.0182) was more frequently absent in the CF group, the absence of glycine (p = 0.0397) was more often observed in the CE group. In the presence of higher levels of MS, free glycine reduced the risk of experiencing dental caries (p = 0.0419). Conversely, the presence of proline was found to increase the risk of experiencing the disease (p = 0.0492).Conclusions: The presence of free proline and absence of free glycine in children with ECC, highly contaminated with MS, increased the chances of experiencing dental caries in the present population. Further studies are needed to better understand this phenomenon. (C) 2008 Elsevier Ltd. All rights reserved.
Resumo:
The purposes of this study were to detect S. mutans and S. sobrinus by polymerase chain reaction (PCR) amplification, and to relate their presence to the incidence of dental caries in 42 Brazilian preschool children. Dental plaque samples were collected from the cervical margin of all erupted teeth of 5-6 years old children with primary dentition, using a sterile explorer. Examination of the dmft (decayed, missing, filled teeth) index, performed following the World Health Organization (WHO) caries diagnostic criteria, showed a 2.71 score. Prevalence of S. mutans and S. sobrinus was respectively, of 85.7% and 14.3%; no dental plaque sample was either positive or negative for both bacterial species. Children harboring either S. mutans or S. sobrinus presented the same caries prevalence. PCR showed good discriminative ability for differentiation between these species, and suggested that it is a technique suitable for epidemiological studies on mutans streptococci.