45 resultados para CLIP


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Complete and partial loss of maxillary bone may jeopardize oral physiology and generate complications as oral-sinus-nasal communication. Palatal obturator prostheses are a treatment alternative for rehabilitation of these patients. The aim of this study was to assess stress distribution, through photoelasticity, on palatal obturator prostheses associated with different attachment systems (o'ring, bar clip, and o'ring/bar clip) of implants and submitted to relining. Two photoelastic models were fabricated according to an experimental maxillary model with oral-sinus-nasal communication. One model did not present implants, whereas the other included 2 implants with 13.0 mm in length in the left ridge. Four colorless maxillary obturator prostheses were fabricated and relined with soft silicone. One of these prostheses presented no attachment system, whereas the remaining prostheses included attachment systems adapted to the implants. The assembly (model/attachment system/prosthesis) was positioned in a circular polariscope during loading with 100 N at 10 mm/s. The results were based on observation during the experiment and photographic records of stress on the photoelastic model. The bar clip system exhibited the highest stress concentration followed by o'ring/bar clip and o'ring systems. The attachment systems presented different stress distribution with greater concentration surrounding the implants and homogenous stress distribution on the photoelastic model without implants. The highest concentration of fringes occurred, in ascending order, with o'ring, o'ring/bar clip, and bar clip systems.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: This study evaluated the effects of growth hormone (GH) on morphology and myogenic regulatory factors (MRF) gene expression in skeletal muscle of rats with ascending aortic stenosis (AAS) induced chronic heart failure.Design: Male 90-100 g Wistar rats were subjected to thoracotomy. AAS was created by placing a stainless-steel clip on the ascending aorta. Twenty five weeks after surgery, rats were treated with daily subcutaneous injections of recombinant human GH (2 mg/kg/day; AAS-GH group) or saline (AAS group) for 14 days. Sham-operated animals served as controls. Left ventricular (LV) function was assessed before and after treatment. IGF-1 serum levels were measured by ELISA. After anesthesia, soleus muscle was frozen in liquid nitrogen. Histological sections were stained with HE and picrosirius red to calculate muscle fiber cross-sectional area and collagen fractional area, respectively. MRF myogenin and MyoD expression was analyzed by reverse transcription PCR.Results: Body weight was similar between groups. AAS and AAS-GH groups presented dilated left atrium, left ventricular (LV) hypertrophy (LV mass index: Control 1.90 +/- 0.15; AAS 3.11 +/- 0.44; AAS-GH 2.94 +/- 0.47 g/kg; p < 0.05 AAS and AAS-GH vs. Control), and reduced LV posterior wall shortening velocity. Soleus muscle fiber area was significantly lower in AAS than in Control and AAS-GH groups; there was no difference between AAS-GH and Control groups. Collagen fractional area was significantly higher in MS than Control; AAS-GH did not differ from both Control and AAS groups. Serum IGF-1 levels decreased in AAS compared to Control. MyoD mRNA was significantly higher in AAS-GH than AAS; there was no difference between AAS-GH and Control groups. Myogenin mRNA levels were similar between groups.Conclusion: In rats with aortic stenosis-induced heart failure, growth hormone administration increases MyoD gene expression above non-treated animal levels, preserves muscular trophism and attenuates interstitial fibrosis. These results suggest that growth hormone may have a potential role as an adjuvant therapy for chronic heart failure. (C) 2009 Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this in vitro study was to evaluate alterations in the surface roughness and micromorphology of human enamel submitted to three prophylaxis methods. Sixty-nine caries-free molars with exposed labial surfaces were divided into three groups. Group I was treated with a rotary instrument set at a low speed, rubber clip and a mixture of water and pumice; group II with a rotary instrument set at a low speed, rubber cup and prophylaxis paste Herjos-F (Vigodent S/A Industria e Comercio, Rio de Janeiro, Brazil); and group III with sodium bicarbonate spray Profi II Ceramic (Dabi A dante Indtistrias Medico Odontologicas Ltda, Ribeirao Preto, Brazil). All procedures were performed by the same operator for 10 s, and samples were rinsed and stored in distilled water. Pre and post-treatment surface evaluation was completed using a surface profilometer (Perthometer S8P Marh, Perthen, Germany) in 54 samples. In addition, the other samples were coated with gold and examined in a scanning electron microscope (SEM). The results of this study were statistically analyzed with the paired t-test (Student), the Kruskal-Wallis test and the Dunn (5%) test. The sodium bicarbonate spray led to significantly rougher surfaces than the pumice paste. The use of prophylaxis paste showed no statistically significant difference when compared with the other methods. Based on SEM analysis, the sodium bicarbonate spray presented an irregular surface with granular material and erosions. Based on this study, it can be concluded that there was an increased enamel stuface roughness when teeth were treated with sodium bicarbonate spray when compared with teeth treated with pumice paste.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study evaluated retention force and fatigue resistance of two overdenture attachment systems. Twenty samples (O-ring and Bar-Clip) from two manufacturers (Conexao Sistemas de Protese and Lifecore Biomedical) were prepared and divided into four groups: (i) Conexao/O-ring; (ii) Conexao/Bar-Clip; (iii) Lifecore/O-ring and (iv) Lifecore/Bar-Clip, with five samples in each group. They were submitted to mechanical fatigue test using a servohydraulic machine performing 5500 cycles of insertion and removal (f=0.8 Hz), immersed in artificial saliva. Retention force values were obtained three times (0, 3000 and after 5500 cycles) simulating the clinical service, using a tensile strength at 1 mm min(-1) and load cell of 1 kN. Data were analysed with analysis of variance and Tukey's test at 5% level. Results showed that Conexao/Bar-Clip specimens had significantly higher retention values than Lifecore/Bar-Clip (44.61 and 18.44 N, respectively), Conexao/O-ring specimens had significantly lower values than Lifecore/O-ring (13.91 and 19.75 N, respectively). Conexao/Bar-Clip values were always significantly higher than those of Conexao/O-ring group (44.61 and 13.91 N, respectively). Lifecore (O-ring and Bar-Clip) presented similar values (19.75 and 18.44 N, respectively). The systems evaluated showed satisfactory retention force values, before and after fatigue testing. Conexao/Bar-Clip specimens presented the highest values. A 5-year simulation of insertion and removal did not decrease retention values or fracture components.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study was designed to analyze the impact of diminished renal perfusion pressure due to renal clipping on the rat model of adriamycin nephropathy. Male Wistar rats, divided into four groups (n = 9 per group) were injected with saline as control (C), adriamycin 3 ml/kg (Ad), saline with the left renal artery clipped (Rv), and adriamycin plus clip (AdRv). After 24 weeks mean arterial pressure (MAP), inulin, and p-aminohippurate (PAH) clearances were performed to evaluate renal function. Morphologic analysis included histologic criteria of percentage of glomerulosclerosis and tubulointerstitial lesion index (TILI). The MAP (mm Hg) was similar between Rv (143 +/- 13) and AdRv (154 +/- 20), but higher (P < .05) than C (120 +/- 8) and Ad (124 +/- 11). Inulin clearance (mL/min/100 g) in Ad (0.2 +/- 0.05) was smaller than in C (0.53 +/- 0.17) and Rv (0.4 +/- 0.01) (P < .05), and was at an intermediate level in AdRv (0.33 +/- 0.2). The level of PAH (mL/min/100 g) was normal at 1.76 in C, and diminished more in Ad (0.58) than in Rv (1.06) and AdRv (1.18) (P < .05). Both Ad and the AdRv nonclipped kidneys had the highest degree of glomerulosclerosis (33% and 25%) and TILI (7% and 8%), respectively, compared with C and Rv (both 0%), whereas the clipped kidneys displayed intermediate degrees (9% and 5%) (P < .05 v nonclipped). The data suggest that diminished perfusion pressure of the clipped kidney, by decreasing the intraglomerular pressure, protects the glomerulus from damage and attenuates the evolution of adriamycin nephropathy. Am J Hypertens 1998;11:1124-1128 (C) 1998 American Journal of Hypertension, Ltd.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A finite element analysis was used to compare the effect of different designs of implant-retained overdentures and fixed full-arch implant-supported prosthesis on stress distribution in edentulous mandible. Four models of an human mandible were constructed. In the OR (O'ring) group, the mandible was restored with an overdenture retained by four unsplinted implants with O'ring attachment; in the BC (bar-clip) -C and BC groups, the mandibles were restored with overdentures retained by four splinted implants with bar-clip anchor associated or not with two distally placed cantilevers, respectively; in the FD (fixed denture) group, the mandible was restored with a fixed full-arch four-implant-supported prosthesis. Models were supported by the masticatory muscles and temporomandibular joints. A 100-N oblique load was applied on the left first molar. Von Mises (σvM), maximum (σmax) and minimum (σmin) principal stresses (in MPa) analyses were obtained. BC-C group exhibited the highest stress values (σvM=398.8, σmax=580.5 and σmin=-455.2) while FD group showed the lowest one (σvM=128.9, σmax=185.9 and σmin=-172.1). Within overdenture groups, the use of unsplinted implants reduced the stress level in the implant/prosthetic components (59.4% for σvM, 66.2% for σmax and 57.7% for σmin versus BC-C group) and supporting tissues (maximum stress reduction of 72% and 79.5% for σmax, and 15.7% and 85.7% for σmin on the cortical and trabecular bones, respectively). Cortical bone exhibited greater stress concentration than the trabecular bone for all groups. The use of fixed implant dentures and removable dentures retained by unsplinted implants to rehabilitate edentulous mandible reduced the stresses in the periimplant bone tissue, mucosa and implant/prosthetic components. © 2013 Elsevier Ltd.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Maxillary defects resulting from cancer, trauma, and congenital malformation affect the chewing efficiency and retention of dentures in these patients. The use of implant-retained palatal obturator dentures has improved the self-esteem and quality of life of several subjects. We evaluate the stress distribution of implant-retained palatal obturator dentures with different attachment systems by using the photoelastic analysis images. Two photoelastic models of the maxilla with oral-sinus-nasal communication were fabricated. One model received three implants on the left side of the alveolar ridge (incisive, canine, and first molar regions) and the other did not receive implants. Afterwards, a conventional palatal obturator denture (control) and two implant-retained palatal obturator dentures with different attachment systems (O-ring; bar-clip) were constructed. Models were placed in a circular polariscope and a 100-N axial load was applied in three different regions (incisive, canine, and first molar regions) by using a universal testing machine. The results were photographed and analyzed qualitatively using a software (Adobe Photoshop). The bar-clip system exhibited the highest stress concentration followed by the O-ring system and conventional denture (control). Images generated by the photoelastic method help in the oral rehabilitator planning. © 2013 SPIE.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Comunicação - FAAC