26 resultados para Cúspide


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Odontologia - FOA

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Odontologia Restauradora - ICT

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Reabilitação Oral - FOAR

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The association of mandibular distal extension removable partial dentures with an osteointegrated implant is a treatment option at hasn't been fully explored by modern rehabilitation dentistry yet. The objective of this study is to evaluate, by means of the bidimensional method of finite elements, the distribution of tension on the structures supporting the distal extension removable partial denture (DERPD), associated to a 10.0 x 3.75 mm osteointegrated implant with an ERA retention system, in alveolar ridges of different shapes. Eight models were created, representing, from a sagittal perspective: Model A (MA) – a half arch with a horizontal ridge without posterior support, with the presence of the lower left canine, and a conventional DERPD, with metallic support in the incisal aspect of this canine, as replacement for the first and second pre-molars and the first and second molars of the lower left half arch; Model B (MB) – similar to MA, but different because of the presence of a 3.75 x 10.00 mm implant with an associated ERA retention system in the posterior region of the DERPD base; Model C (MC) - similar to MA, however with a distally ascending ridge format; Model D (MD) – similar to MC, but different because there is an implant associated to a retention system; Model E (ME) - similar to MA, however with a distally descending ridge format; Model F (MF) – similar to ME, but ditfferent in the sense that there is an implant with an associated ERA retention system; Model G (MG) – similar to MA, however with a distally descending-ascending ridge format; Model H (MH) – similar to MG, but different in the sense that there is an implant with an associated ERA retention system. The finite element program ANSYS 9.0 was used to load the models with vertical forces of 50 N, on each cuspid tip. The format of distal descending edge (ME and MF) was that presented worse results, so in the models with conventional RPD as in the models with RPD associated to the implant and ERA system of retention, for the structures gingival mucosa and tooth support. 1) the distally descending ridge presented the most significant stress in the model with the conventional RPD (ME) or with a prosthesis associated to an implant (MF) and 2) the horizontal ridge (MB) provided more relief to the support structures, such as the tooth and the spongy bone, when there was an implant associated to an ERA retention system. The incorporation of the implants with the ERA system retention, in the posterior area of the toothless edge, it promotes larger stability and retention to PPREL, improving the patient's masticatory acting and, consequently, its comfort and function.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The alveolar ridge shape plays an important role in predicting the demand on the support tooth and alveolar bone in the removable partial denture (RPD) treatment. However, these data are unclear when the RPD is associated with implants. This study evaluated the influence of the alveolar ridge shape on the stress distribution of a free-end saddle RPD partially supported by implant using 2-dimensioanl finite element analysis (FEA). Four mathematical models (M) of a mandibular hemiarch simulating various alveolar ridge shapes (1-distal desceding, 2- concave, 3-horizontal and 4-distal ascending) were built. Tooth 33 was placed as the abutment. Two RPDs, one supported by tooth and fibromucosa (MB) and other one supported by tooth and implant (MC) were simulated. MA was the control (no RPD). The load (50N) were applied simultaneously on each cusp. Appropriate boundary conditions were assigned on the border of alveolar bone. Ansys 10.0 software was used to calculate the stress fields and the von Mises equivalent stress criteria (σvM) was applied to analyze the results. The distal ascending shape showed the highest σvM for cortical and medullar bone. The alveolar ridge shape had little effect on changing the σvM based on the same prosthesis, mainly around the abutment tooth.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The rehabilitation with mandibular distal extension removable partial dentures (DERPD) is complex and the use of implants has been improving the functioning of this approach. The insertion bony level around of the last support tooth is an aggravating factor, since it can harm the longevity of the treatment. Thus, the aim of this research was to evaluate the displacement tendency of a mandibular DERPD associated to an implant, with different insertion bony levels and different connections between the RPD and the support tooth, by finite element analysis. Eight models were made: MA - DERPD, incisal rest, no bony loss; MB - DERPD, distal plate, no bony loss; MC - DERPD, incisal rest, no bony loss, with implant and ERA system; MD - DERPD, distal plate, no bony loss, with implant and ERA system; ME - DERPD, incisal rest, bony loss; MF - DERPD, distal plate, bony loss; MG - DERPD, incisal rest, bony loss, with implant and ERA system; MH - DERPD, distal plate, bony loss, with implant and ERA system. Loads of 50 N in each peak were applied. Displacement maps were obtained and showed that implant favors this association and the bony loss harms the prognostic of the prosthesis. It is concluded that: the introduction of the implant with ERA system reduced the displacement tendency of the tooth and supporting structures; introduction of distal plate reduced the movement tendency of the support tooth; the decrease of the periodontal support didn't influence significantly the displacement tendency of the models with distal plate distal, but it influenced the models with distal incisal rest.