156 resultados para Automatic exposure control system


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper is based on the analysis and implementation of a new drive system applied to refrigeration systems, complying with the restrictions imposed by the IEC standards (Harmonic/Flicker/EMI-Electromagnetic Interference restrictions), in order to obtain high efficiency, high power factor, reduced harmonic distortion in the input current and reduced electromagnetic interference, with excellent performance in temperature control of a refrigeration prototype system (automatic control, precision and high dynamic response). The proposal is replace the single-phase motor by a three-phase motor, in the conventional refrigeration system. In this way, a proper control technique can be applied, using a closed-loop (feedback control), that will allow an accurate adjustment of the desirable temperature. The proposed refrigeration prototype uses a 0.5Hp three-phase motor and an open (Belt-Drive) Bitzer IY type compressor. The input rectifier stage's features include the reduction in the input current ripple, the reduction in the output voltage ripple, the use of low stress devices, low volume for the EMI input filter, high input power factor (PF), and low total harmonic distortion (THD) in the input current, in compliance with the IEC61000-3-2 standards. The digital controller for the output three-phase inverter stage has been developed using a conventional voltage-frequency control (scalar V/f control), and a simplified stator oriented Vector control, in order to verify the feasibility and performance of the proposed digital controls for continuous temperature control applied at the refrigerator prototype. ©2008 IEEE.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Along with the advance of technology, in terms of the expansion of medical exams that uses the ionizing radiation for diagnosis, there is also the concern about quality control for maintaining quality in radiographic imaging and for delivering low dose to the patient. Based on the Federal Order 453 of the Secretariat of Health Surveillance, which takes account of the practical and justification of individual medical exposures, the optimization of radiological protection, limitation of individual dose, and the prevention of accidents, were done through this paper radiodiagnostic tests on medical equipment in order to accept it or not, according to SVS-453. Along with the help and support of P&R Consulting and Medical Physics Marilia, SP, were made Quality Control and Radiometric Control in equipment from various cities across the state of São Paulo. The equipment discussed in this work is classified as conventional X-ray. According to the Federal Order SVS-453, the quality control in the program of quality assurance should include the following minimum set of constancy tests, with following minimum frequency: biennial tests for representative values of dose given to the patients of radiography and CT performed in the service; annual tests for accuracy of the indicator tube voltage (kVp), accuracy of exposure time, half-value layer, aligning the central axis of the beam of x-ray tube, performance (mGy / mA.min.m²), linearity of the rate of kerma on air with the mAs, reproducibility of the kerma on air rates, reproducibility of the automatic exposure, focal spot size, integrity of accessories and clothing for individual protection; semiannually for collimation system accuracy; weekly for temperature processing system and sensitometry processing system. For the room Radiometric Survey it was done a sketch...(Complete abstract click electronic access below)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Os objetivos deste trabalho foram quantificar as exposições dérmicas (EDs) e respiratórias (ERs) proporcionadas ao piloto e ao seu ajudante nas aplicações de herbicidas para o controle de plantas daninhas aquáticas com aerobarco; classificar essas condições de trabalho em seguras ou inseguras; e calcular a necessidade de controle das exposições (NCE) e o tempo de trabalho seguro (TTS). O aerobarco utilizado tinha casco de alumínio (4,85 x 2,42 m) e acionamento por hélice acoplada a motor a gasolina de 350 HP. O equipamento de pulverização era composto por bomba de diafragma com fluxo máximo de 49,69 L min-1, pressão máxima de 25 kg cm-2, acionada por motor a gasolina de 4 HP, e tanque de calda de 189 L. A barra de pulverização de alumínio era composta de duas seções laterais de 3 m, posicionadas na linha entre o encosto do banco do piloto e o início da estrutura protetora da hélice. Cada seção da barra tinha seis bicos com pontas de jato plano com indução de ar AI 100 03, espaçados de 0,5 m, e uma ponta OC 20 fixada em cada extremidade. O conjunto de pontas pulverizava faixas de 6 m de largura e aplicava o volume de calda de 200 L ha-1. O sistema tinha gerenciador de fluxo, controlado por central eletrônica acoplada a DGPS (com precisão submétrica), para corrigir automaticamente a vazão em função de alterações na velocidade real da embarcação. As EDs e ERs aos herbicidas foram calculadas com os dados substitutos das exposições às caldas, avaliadas com os traçadores cobre e manganês adicionados às caldas. As exposições foram extrapoladas para uma jornada de trabalho de seis horas. A segurança das condições de trabalho foi determinada com o cálculo da margem de segurança (MS), utilizando-se a fórmula MS = (NOEL x 70)/(QAE x 10), em que QAE = quantidade absorvível da exposição. As condições de trabalho foram classificadas em seguras, se MS>1, ou inseguras, se MS<1. As exposições proporcionadas pelas condições de trabalho foram de 10,65 mL de calda por dia para o piloto e de 16,80 mL por dia para o ajudante, que fica sentado em uma cadeira a 2,0 m à frente do piloto e da barra de pulverização. Classificaram-se como seguras as aplicações dos herbicidas glyphosate (Rodeo, 6 L ha-1), 2,4D (DMA 806 BR, 8 L ha-1) e fluridone (Sonar AQ, 0,4 L ha-1), para o piloto e o seu ajudante. Classificou-se como insegura a aplicação do herbicida diquat (Reward, 4,0 L ha-1) para as duas condições de trabalho, cujas necessidades de controle das exposições calculadas foram de 65% para o piloto e de 78% para o ajudante do piloto.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pacu juveniles (5.2 [plus or minus] 1.5 g) were submitted to two one-minute air exposures in a 24h interval, and sampled before the exposure (control) and 5, 15, 30 and 60 min., 24 and 48h afterwards for whole-body cortisol, sodium, potassium and calcium ion concentrations. For the first air exposure, there was a trend of increased cortisol concentration after 15 min., whereas in the second air exposure, the cortisol concentration increased significantly within 5 min. after stress was induced. Sodium ion concentration increased significantly 24h after both air exposures. Potassium concentration presented fluctuations over the experimental period. Calcium ion concentration increased progressively from 5 to 30 min., in both air exposures. The repeated air exposures exacerbated the cortisol response, but they did not affect the recovery ability of pacu over the experimental period. Additionally, the whole-body cortisol measurement might be a reliable indicator of stress, when sampled fish are smaller and blood volumes are very low, making samples inadequate for analysis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to develop a laboratory method for time response evaluation on electronically controlled spray equipment using Programmable Logic Controllers (PLCs). For that purpose, a PLC controlled digital drive inverter was set up to drive an asynchronous electric motor linked to a centrifugal pump on a experimental sprayer equipped with electronic flow control. The PLC was operated via RS232 serial communication from a PC computer. A user program was written to control de motor by adjusting the following system variables, all related to the motor speed: time stopped; ramp up and ramp down times, time running at a given constant speed and ramp down time to stop the motor. This set up was used in conjunction with a data acquisition system to perform laboratory tests with an electronically controlled sprayer. Time response for pressure stabilization was measured while changing the pump speed by +/-20%. The results showed that for a 0.2 s ramp time increasing the motor speed, as an example, an AgLogix Flow Control system (Midwest Technologies Inc.) took 22 s in average to readjust the pressure. When decreasing the motor speed, this time response was down to 8 s. General results also showed that this kind of methodology could make easier the definition of standards for tests on electronically controlled application equipment.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A Neuropatia diabética periférica (NDP) cursa com redução somatossensitiva que pode levar a alterações no controle postural. O objetivo do estudo foi avaliar o controle postural na postura ereta, em diferentes condições, e o equilíbrio funcional em indivíduos com NDP, correlacionar os resultados obtidos na avaliação do controle postural com os valores do teste do equilíbrio funcional e comparar os resultados obtidos no grupo neuropata com o grupo controle, verificando as possíveis diferenças entre as condições de avaliação em ambos os grupos. Participaram do estudo 13 mulheres com NDP (GN) e 17 mulheres não diabéticas (GC). A avaliação do controle postural foi realizada por cinemetria nas condições: olhos abertos (OA), olhos fechados (OF) e semi tandem (ST). Após processamento no MATLAB, foram geradas as variáveis: amplitude média de oscilação (AMO) na direção ântero-posterior (AP) e médio-lateral (ML); e velocidade média de oscilação (VMO) na direção AP e ML. O equilíbrio funcional foi avaliado pelo Timed Up and Go Test. Houve diferença significante entre os grupos (p<0,005) na AMO-AP OA e OF, AMO-ML of e ST e VMO-ML ST. Houve diferença entre as condições OA e ST (p<0,005) e of e ST (p<0,005) para as variáveis AMO-ML e VMO-ML, com maior prejuízo para o GN, que também apresentou um menor equilíbrio funcional (p=0,001). A instabilidade ML foi correlacionada positivamente com o desequilíbrio funcional. Os resultados nos mostram uma alteração no sistema de controle postural na NDP, o que pode levar estes indivíduos a um maior risco a quedas e prejuízos funcionais.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper, we introduce the concept of dynamic Morse decomposition for an action of a semigroup of homeomorphisms. Conley has shown in [5, Sec. 7] that the concepts of Morse decomposition and dynamic Morse decompositions are equivalent for flows in metric spaces. Here, we show that a Morse decomposition for an action of a semigroup of homeomorphisms of a compact topological space is a dynamic Morse decomposition. We also define Morse decompositions and dynamic Morse decompositions for control systems on manifolds. Under certain condition, we show that the concept of dynamic Morse decomposition for control system is equivalent to the concept of Morse decomposition.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents a simple but practical feedback control method to suppress the vibration of a flexible structure in the frequency range between 10 Hz and 1 kHz. A dynamic vibration absorber is designed for this, which has a natural frequency of 100 Hz and a normalized bandwidth (twice the damping ratio) of 9.9. The absorber is realized electrically by feeding back the structural acceleration at one position on the host structure to a collocated piezoceramic patch actuator via an analog controller consisting of a second-order lowpass filter. This absorber is equivalent to a single degree-of-freedom mechanical oscillator consisting of a serially connected mass-spring-damper system. A first-order lowpass filter is additionally used to improve stability at very high frequencies. Experiments were conducted on a free-free beam embedded with a piezoceramic patch actuator and an accelerometer at its center. It is demonstrated that the single absorber can simultaneously suppress multiple vibration modes within the control bandwidth. It is further shown that the control system is robust to slight changes in the plant. The method described can be applied to many other practical structures, after retuning the absorber parameters for the structure under control.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Oxidative stress is considered a possible molecular mechanism involved in Pb neurotoxicity. Considering the vulnerability of the developing brain to Pb neurotoxicity, this study was carried out to investigate the effects of low-level developmental Pb exposure on brain regions antioxidant enzymes activities. Wister dams were exposed to 500 ppm of Pb, as Pb acetate, or to 660 ppm Na acetate in the drinking water during pregnancy and lactation. The activities of superoxide dismutase (SOD), glutathione peroxidase and glutathione reductase were determined in the hypothalamus, hippocampus and striatum of male pups at 23 (weaned) or 70 days (adult) of age. In the Pb-exposed 23-day-old pups, the activity of SOD was decreased in the hypothalamus. Regarding adults, there was no significant treatment effect in any of the enzymes and regions evaluated. Based on the present results, it seems that oxidative stress due to decreased antioxidant function may occur in weaned rats but it is suggested that this should not be the main mechanism involved in the neurotoxicity of low-level Pb exposure. (C) 2001 Elsevier B.V. Ireland Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work presents the design of a fuzzy controller with simplified architecture that use an artificial neural network working as the aggregation operator for several active fuzzy rules. The simplified architecture of the fuzzy controller is used to minimize the time processing used in the closed loop system operation, the basic procedures of fuzzification are simplified to maximum while all the inference procedures are computed in a private way. As consequence, this simplified architecture allows a fast and easy configuration of the simplified fuzzy controller. The structuring of the fuzzy rules that define the control actions is previously computed using an artificial neural network based on CMAC Cerebellar Model Articulation Controller. The operational limits are standardized and all the control actions are previously calculated and stored in memory. For applications, results and conclusions several configurations of this fuzzy controller are considered.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The general objective of this work was to develop a monitoring and management model for aquatic plants that could be used in reservoir cascades in Brazil, using the reservoirs of AES-Tiete as a study case. The investigations were carried out at the reservoirs of Barra-Bonita, Bariri, Ibitinga, Promissao, and Nova-Avanhandava, located in the Tiete River Basin; Agua Vermelha, located in the Grande River Basin; Caconde, Limoeiro, and Euclides da Cunha, which are part of the Pardo River Basin; and the Mogi-Guacu reservoir, which belongs to the Mogi-Guacu River basin. The main products of this work were: development of techniques using satellite-generated images for monitoring and planning aquatic plant control; planning and construction of a boat to move floating plant masses and an airboat equipped with a DGPS navigation and application flow control system. Results allowed to conclude that the occurrence of all types of aquatic plants is directly associated with sedimentation process and, consequently, with nutrient and light availability. Reservoirs placed at the beginning of cascades are more subject to sedimentation and occurrence of marginal, floating and emerged plants, and are the priority when it comes to controlling these plants, since they provide a supply of weeds for the other reservoirs. Reservoirs placed downstream show smaller amounts of water-suspended solids, with greater transmission of light and occurrence of submerged plants.