26 resultados para Automatic Peak Detection


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives: To evaluate the accuracy of three different cutoff points for the detection of high blood pressure in adolescents, given the strong relationship between overweight and high blood pressure levels.Methods: A total of 1,021 adolescents of both sexes were enrolled in the study, selected at random from public and private schools in Londrina, Brazil. Their body weight was measured using a digital balance, and their height with a portable stadiometer with a maximum extension of 2 meters. Arterial blood pressure was measured using an automatic apparatus. The capacity of body mass index to detect high blood pressure was gauged using ROC curves and their parameters (sensitivity, specificity, and area under the curve).Results: The cutoff points proposed in a Brazilian standard exhibited greater accuracy (males: 0.636 +/- 0.038; females: 0.585 +/- 0.043) than the cutoff points proposed in an international (males: 0.594 +/- 0.040; females: 0.570 +/- 0.044) and a North-American standard (males: 0.612 +/- 0.039; females: 0.578 +/- 0.044).Conclusions: The Brazilian proposal offered greatest accuracy for indicating high blood pressure levels.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Reliable spectral analysis is only achieved if the spectrum is thoroughly investigated in regard to all hidden and overlapped peaks. This paper describes the steps undertaken to find and separate such peaks in the range of 3000 to 4000 cm(-1) in the case of three different infrared absorption spectra of the glass surface of hydrolyzed silica optical fibers. Peak finding was done by the analysis of the second and fourth derivatives of the digital data, coupled with the available knowledge of infrared spectroscopy of silica-water interaction in the investigated range. Peak separation was accomplished by curve fitting with four different models. The model with the best fit was described by a sum of pure Gaussian peaks. Shoulder limit and detection limit maps were used to validate the revealed spectral features.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Procion red HE-3B (RR120) is an example of dye currently used in affinity purification. A method is described for determining trace amounts of RR120 dye contaminant in human serum albumin by cathodic stripping voltammetry. The method is based on a measure of a well-defined peak at -0.58 V, obtained when samples of HSA protein (0.01-2% w/v) containing dye concentrations are submitted to a heating time of 330 min at 80degreesC in NaOH, pH 12.0 and the samples are removed to a solution containing Britton-Robinson buffer, pH 4.0. Using an optimum accumulation potential and tune of 0 V and 240 s, respectively, linear calibration curves were obtained from 1.0 X 10(-9) to 1.0 X 10(-8) mol 1(-1) for RR120 dye. Leakage/hydrolysis of reactive red 120 from an agarose support (e.g. at pH 2 or 12) can also be conveniently determined at very low levels (sub-mug ml(-1)) by means of cathodic stripping voltammetry, which involves adsorptive accumulation of the dye onto the hanging mercury-drop electrode. (C) 2002 Elsevier B.V. B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Two experiments were carried out to evaluate a larval development assay for the detection of anthelmintic resistance in O. circumcincta. In Experiment I, the dose responses to levamisole (LEV), thiabendazole (TBZ) and ivermectin (IVM) of 8 isolates of O. circumcincta were measured 34 days after infection (DAI). Four of these isolates were shown to be resistant to 1 or more anthelmintics. With 2 exceptions, all isolates considered to be resistant had higher LD50 values than the susceptible isolates for that anthelmintic. One exception was isolate RM8, which was considered to be resistant to all 3 anthelmintics based on faecal egg count reduction tests in goats, but the LD50 value for LEV did not differ from that for the susceptible isolates. The other exception was an isolate considered to be susceptible to TBZ which had a relatively high LD50 value. In an unrelated trial that was prompted by this finding, this isolate was confirmed to be benzimidazole-resistant. Isolate RM8 and an isolate susceptible to all 3 anthelmintics (SK2) were used in the second experiment, which was conducted to monitor changes in the LD50 values of LEV, TBZ and IVM over time following a single infection of 35 000 infective larvae in young sheep. Faecal samples were collected weekly from 24 to 115 DAI. With all 3 anthelmintics, the LD50 values increased with time to a peak around 50-60 DAI, and then declined to levels similar to those observed soon after patency. This trend was consistent for both isolates. The highest mean LD50 values for isolates SK2 for IVM and TBZ and RM8 for IVM and RM8, respectively, were 1.7 and 1.8 times, and 2.2 and 2.9 times higher than the initial mean LD50 values. There was a clear distinction in LD50 values between isolates at each sampling day for both IVM and TBZ. However, as a consequence of the changes in LD50 values with time, the peak LD50 values of IVM for isolate SK2 were higher than the minimum LD50 values of isolate RM8. As there was no apparent difference in LEV efficacy between these 2 isolates, the data were pooled. The highest mean LD50 value was 2.3 times higher than the initial LD50 value. (C) 1997 Australian Society for Parasitology.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper describes lightning characteristics as obtained in four sets of lightning measurements during recent field campaigns in different parts of the world from mid-latitudes to the tropics by the novel VLF/LF (very low frequency/low frequency) lightning detection network (LINET). The paper gives a general overview on the approach, and a synopsis of the statistical results for the observation periods as a whole and for one special day in each region. The focus is on the characteristics of lightning which can specifically be observed by this system like intra-cloud and cloud-to-ground stroke statistics, vertical distributions of intra-cloud strokes or peak current distributions. Some conclusions regarding lightning produced NOx are also presented as this was one of the aims of the tropical field campaigns TROCCINOX (Tropical Convection, Cirrus and Nitrogen Oxides Experiment) and TroCCiBras (Tropical Convection and Cirrus Experiment Brazil) in Brazil during January/February 2005, SCOUT-O3 (Stratospheric-Climate Links with Emphasis on the Upper Troposphere and Lower Stratosphere) and TWP-ICE (Tropical Warm Pool-International Cloud Experiment) during November/December 2005 and January/February 2006, respectively, in the Darwin area in N-Australia, and of AMMA (African Monsoon Multidisciplinary Analyses) in W-Africa during June-November 2006.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents results from an efficient approach to an automatic detection and extraction of human faces from images with any color, texture or objects in background, that consist in find isosceles triangles formed by the eyes and mouth.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The main purpose of this work is the development of computational tools in order to assist the on-line automatic detection of burn in the surface grinding process. Most of the parameters currently employed in the burning recognition (DPO, FKS, DPKS, DIFP, among others) do not incorporate routines for automatic selection of the grinding passes, therefore, requiring the user's interference for the choice of the active region. Several methods were employed in the passes extraction; however, those with the best results are presented in this article. Tests carried out in a surface-grinding machine have shown the success of the algorithms developed for pass extraction. Copyright © 2007 by ABCM.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents a Computer Aided Diagnosis (CAD) system that automatically classifies microcalcifications detected on digital mammograms into one of the five types proposed by Michele Le Gal, a classification scheme that allows radiologists to determine whether a breast tumor is malignant or not without the need for surgeries. The developed system uses a combination of wavelets and Artificial Neural Networks (ANN) and is executed on an Altera DE2-115 Development Kit, a kit containing a Field-Programmable Gate Array (FPGA) that allows the system to be smaller, cheaper and more energy efficient. Results have shown that the system was able to correctly classify 96.67% of test samples, which can be used as a second opinion by radiologists in breast cancer early diagnosis. (C) 2013 The Authors. Published by Elsevier B.V.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A glassy carbon electrode chemically modified with nickel nanoparticles coupled with reversed-phase chromatography with pulsed amperometric detection was used for the quantitative analysis of furanic aldehydes in a real sample of sugarcane bagasse hydrolysate. Chromatographic separation was carried out in isocratic conditions (acetonitrile/water, 1:9) with a flow rate of 1.0 mL/min, a detection potential of -50 mV vs. Pd, and the process was completed within 4 min. The analytical curves presented limits of detection of 4.0 × 10(-7) mol/L and 4.3 × 10(-7) mol/L, limits of quantification of 1.3 × 10(-6) and 1.4 × 10(-6) mol/L, amperometric sensitivities of 2.2 × 10(6) nA mol/L and 2.7 × 10(6) nA mol/L for furfural and 5-hydroxymethylfurfural, respectively. The values obtained in this sample by the standard addition method were 1.54 ± 0.02 g/kg for 5-hydroxymethylfurfural and 11.5 ± 0.2 g/kg for furfural. The results demonstrate that this new proposed method can be used for the quick detection of furanic aldehydes without the interference of other electroactive species, besides having other remarkable merits that include excellent peak resolution, analytical repeatability, sensitivity, and accuracy.