84 resultados para Apparent porosity


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Several researches have been developed in order to verify the porosity effect over the ceramic material properties. The starch consolidation casting (SCC) allows to obtain porous ceramics by using starch as a binder and pore forming element. This work is intended to describe the porous mathematical behavior and the mechanical resistance at different commercial starch concentration. Ceramic samples were made with alumina and potato and corn starches. The slips were prepared with 10 to 50 wt% of starch. The specimens were characterized by apparent density measurements and three-point flexural test associated to Weibull statistics. Results indicated that the porosity showed a first-order exponential equation e(-x/c) increasing in both kinds of starches, so it was confirmed that the alumina ceramic porosity is related to the kind of starch used. The mechanical resistance is represented by a logarithmic expression R = A + B/1+10((Log(x0)-P)C).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a simple, fast and sensitive method to determine chromic oxide (used as a biological marker of fish feed) in samples of fish feces by GFAAS through the direct introduction of slurries of the samples into the spectrometer's graphite tube. The standard samples of feces and of fish feed containing 0.10-1.00 mg kg(-1) of Cr2O3 were pre-frozen for I min in liquid nitrogen and then ground a cryogenic mill for 2 min, which reduced the samples' grain size to less than 60 mu m. The standard slurries were prepared by mixing 20 mg of standard samples of fish feed or feces with I mL of a solution containing 0.05% (v/v) of Triton X-100 and 0.50% (v/v) of suprapure HNO3 directly in the spectrometer's automatic sampling glass. The final concentrations of Cr2O3 present in the standard slurries were 2, 4, 8, 16 and 20 mu g L-1. After sonicating the mixture for 20s, 10 mu L of standard slurries were injected into the graphite tube, whose internal wall was lined with a metallic palladium film that acted as a permanent chemical modifier. The limits of detection (LOD) and quantification (LOQ) calculated for 20 readings of the blank of the standard slurries (2%, m/v of feces or feed devoid of minerals) were 0.81 and 2.70 mu g L-1 of Cr2O3 for the standard feces slurries, 0.84 and 2.83 mu g L-1 of Cr2O3 for the standard feed slurries. The proposed method was applied in studies of nutrient digestibility of different fish feeds and its results proved compatible with the results obtained from samples pre-mineralized by acid digestion. (c) 2005 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Foram utilizados quatro cavalos castrados sem raça definida pelo delineamento em blocos casualizados. Objetivou-se viabilizar os indicadores internos indigestíveis, FDNi e FDAi, obtidas pelas técnicas in situ nos bovinos e in vivo nos equinos por meio do saco de náilon móvel (SNM). Os tratamentos consistiram de digestibilidade determinada por método direto com a coleta total de fezes (CT) e indireto pelo uso de FDNi e FDAi obtidos pelas técnicas in situ (IS) na cavidade ruminal de bovinos e in vivo (IV) nos equinos por meio do SNM. As FDNi-IV e FDAi-IV promoveram a melhor taxa de recuperação (TR) do indicador, igualando-se ao grupo CT, em 91,50%, enquanto a técnica in situ resultou nas piores taxas, na média 86,50%, para ambos os indicadores indigestíveis (p < 0,05). As estimativas dos CD dos nutrientes foram adequadamente preditos pela FDAi-IV, para equinos alimentados com feno, no qual os valores observados foram de 46,41; 48,16; 47,92 e 45,51% para MS, MO, FDN e EB, respectivamente. Concluiu-se que o SNM em equinos pode ser usado para obter a FDAi em equinos alimentados exclusivamente com feno de coast-cross e para cavalos consumindo dieta mista, as FDNi e FDAi foram eleitas para predizer CD de nutrientes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Foram utilizados quatro cavalos castrados sem raça definida, distribuídos em blocos casualizados. Objetivou-se estudar a viabilização dos indicadores internos, celulose (CELi) e lignina indigestíveis (LIGi), para predizer a digestibilidade em cavalos. Os tratamentos consistiram na determinação da digestibilidade por método direto com a coleta total de fezes (CT) e indireto pelo uso CELi e LIGi obtidos pelas técnicas in situ (IS) na cavidade ruminal de bovinos e in vivo (IV) nos equinos por meio do saco de náilon móvel (SNM). A produção fecal e taxa de recuperação (p > 0,05) médios encontrados foram de 2,80 kg na MS e 101%, respectivamente. As estimativas dos CD dos nutrientes (p > 0,05) foram adequadamente preditos pela CELi e LIGi, obtidos in situ e in vivo, no qual os valores médios observados foram de 52,63, 54,17, 64,90, 43,73 e 98,28% para MS, MO, PB, FDN e Amido, respectivamente. Concluiu-se que a CELi e LIGi podem ser obtidas in vivo por meio do SNM em equinos, para predizer os coeficientes de digestibilidade de nutrientes, consumindo dieta mista.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Ultrasonic excitation (US) was applied to glass ionomer cement (GIC) during early set time to increase the advantageous properties of this material. Purpose: The aim of this in vitro study was to assess the inner porosity of GIC after US. Study design: A total of 16 specimens, for each material, were prepared from high-viscosity GIC Fuji IX GP, Ketac Molar, and Ketac Molar Easymix. Half of these specimens (n = 8) received 30 s of US during the initial cement setting. After completion of the material setting, specimens were fractured and observed by scanning electronic microscopy to quantitatively assay porosity inside the material using Image J software. Results: Statistical data analysis revealed that US reduced the porosity for all tested materials (P <= 0.05). The following reductions (expressed in percentages) were achieved: Fuji IX-from 3.9% to 2.8%; Ketac Molar Easy Mix-from 4.4% to 2.6%, and Ketac Molar-from 2.4% to 1.6%. Conclusion: Under the tested conditions, US was an effective method for porosity reduction inside the material. Microsc. Res. Tech. 74:54-57, 2011. (C) 2010 Wiley-Liss, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to evaluate the presence of porosities inside the glass ionomer cement (GIC) after different techniques of material insertion. MATERIAL and METHOD: Specimens were prepared with high-viscosity GIC Ketac Molar Easymix and divided into three groups according to the insertion method: spatula (PI), Centrix injector (CI), and low-cost syringe (LCS). The specimens were fractured and observed with scanning electronic microscopy to quantitatively evaluate porosity inside the material using Image J Software. RESULTS: Statistical analysis, ANOVA application, and Tukey test to significance level of 5%, revealed that there was no statistical difference between the groups. CONCLUSION: Although the use of LCS has not decreased the porosity of the material, this insertion method is easy, accessible, and low cost, which makes it a viable alternative of use in the ART technique and in others bucal health programs. Microsc. Res. Tech., 2012. (c) 2012 Wiley Periodicals, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Microwave energy has proved to be an effective method for disinfecting acrylic dentures. However, the effect of microwave heating on the porosity of autopolymerising denture reline resins has not been investigated.The purpose of the study was to determine the effect of microwave disinfection on the porosity of autopolymerised denture reline materials (Kooliner-K, New Truliner-NT, Tokuso Rebase Fast-TR and Ufi Gel Hard-UGH) and a conventional heat-polymerised denture base resin (Lucitone 550-L).Specimens (10 mm x 20 mm x 1 mm) were obtained from the impression surface of the palatal mucosa in a single person and divided into four groups (n = 5). The porosity was evaluated after polymerisation (C1), after two cycles of microwave disinfection (MW2), after seven cycles of microwave disinfection (MW7) and after 7 days storage in water at 37 degrees C (C2). Specimens from group MW7 were exposed to microwave disinfection daily being stored in water at 37 degrees C between exposures. All the replicas were sputter coated with gold and micrographs/digital images were taken of each replica using scanning electron microscopy at magnification x 100. The SEM micrographs were then examined using an image analyser to determine the number of pores. Comparison between materials and groups were made using Kruskal-Wallis tests.MW7 resulted in a significant increase in the number from the pores of material K, but decreased in number in reline material TR and UGH reline resin. The number of pores in materials NT and L remained unaffected following microwave disinfection.Differences in the porosity amongst the materials and for different experimental conditions were observed following microwave disinfection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The karyotype of a new species of Paratelmatobius from the P cardosoi group is described. As with other Paratelmatobius and Scythrophrys karyotypes, Paratelmatobius sp. (aff. cardosoi) shows a diploid number of 24 chromosomes, in addition to other similarities with the former karyotypes. The Paratelmatobius sp. (aff. cardosoi) karyotype differs from that of P. cardosoi in the morphology of pair 4, the NOR location and the C-bands in pairs 3 and 8 (exclusive to Paratelmatobius sp.) and those of pairs 7 and 9 (exclusive to P. cardosoi). Both karyotypes also differ in the amount of heterochromatin in pair 1. The presence of interstitial heterochromatin in the long arm of pair 1 and the interstitial C-bands in both arms of chromosome 5 are apparently synapomorphic characters of P. cardosoi and Paratelmatobius sp. (aff. cardosoi), since they are absent in the other Paratelmatobius and Scythrophrys karyotypes. In Paratelmatobius sp. (aff. cardosoi), the nucleolus organizer region is on the short arm of a small metacentric chromosome (pair 9), an arrangement similar to the NOR-bearing chromosome pair in the karyotype of P. poecilogaster and in karyotype 11 of Scythrophrys. A conspicuous heteromorphism unrelated to the sex determining mechanism was also observed and probably arose from a pericentric inversion.