41 resultados para Amplitude dos PMOs


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Experimental programs in constant and variable amplitude loading were performed to obtain a x N curves and to study retardation in fatigue crack growth due to overloads. The main aim of this research program was to analyse the effect of overload ratio and number of overload peaks. The effect of underloads, before and after the overload blocks was also studied. The generalised equation of Paris-Erdogan type was used for modelling of obtained data on crack propagation under constant amplitude load.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present analytical and numerical results for the specific heat and susceptibility amplitude ratios in parallel plate geometries. The results are derived using field-theoretic techniques suitable to describe the system in the bulk limit, i.e., (L/ξ±)≫ 1, where L is the distance between the plates and ξ± is the correlation length above (+) and below (-) the bulk critical temperature. Advantages and drawbacks of our method are discussed in the light of other approaches previously reported in the literature.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The leading-twist pion-distribution amplitude is obtained at a low normalization scale of order ρc (inverse average size of an instanton). Pion dynamics, consistent with gauge invariance and low-energy theorems, is considered within the instanton vacuum model. The results are QCD-evolved to higher momentum-transfer values and are in agreement with recent data from CLEO on the pion transition form factor. It is also shown that some previous calculations violate the axial Ward-Takahashi identity. © 2001 MAIK Nauka/Interperiodica.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple constant-current electrocutaneous stimulator for high-impedance loads using low-cost, standard high-voltage components is presented. A voltage-regulator powers an oscillator built across the primary of a transformer whose secondary delivers, after rectification, the high-voltage supply to switched current-mirrors in the driving stage. Since the compliance high-voltage is proportional to the stimulation current, overall power consumption is minimized. By adjusting the regulated voltage, control of the pulsed-current amplitude is achieved. A prototype with readily available components features stimulation currents of amplitude and pulsewidth in the range 0≤Iskin≤20mA and 50μs ≤Tpulse≤1ms, respectively. Pulse-repetition spans from 1 Hz to 10Hz. Worst-case ripple is 3.7% @Iskin=1mA. Measured pulse fall-time is shorter than 32μs. Overall consumption is 4.4W @Iskin=20mA. Subject isolation from line is 4KV.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The massless 4-point one-loop amplitude computation in the pure spinor formalism is shown to agree with the computation in the RNS formalism. © SISSA 2006.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In order to evaluate the influence of exercise of different intensities on Red Blood Cell Distribution width (RDW) and Packed Cell Volume (VG) in Thoroughbred horses, blood was collected from 60 animals, 30 males and 30 females, subdivided in groups of horses with 24 to 36 months of age and not in training, and after 12 months of training, and horses with 36 to 48 months of age in training. Blood samples where collected before and after trot and gallop. Samples where analyzed with a automatic cell counter (Cell-Dyn 3500R, Abbott Diagnostic). Red Blood Cell Distribution width (RDW) values increased significantly after trot and gallop demonstrating a variation in the size of red blood cells, while Packed Medium Cell Volume (VGM) values did not show variations before or after exercise.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work we use a stabilized holographic technique to study both refractive index and absorption gratings recorded in thin films made of Disperse Red 1 (DR1) embedded in an organic polymer matrix (PMMA) deposited on glass substrate. Gratings are recorded by linearly polarized illumination with the interference pattern of two crossing beams. One of the beams is phase modulated and the interference signals between the transmitted and diffracted waves are detected by a tuned lock-in amplifier. The technique allows measuring separately changes of the refractive index and the absorption coefficient during the course of the photoreaction process. The time evolution of the diffraction efficiencies during recording has shown bi-exponential kinetics for both gratings. © 2008 American Institute of Physics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present results from a study of pp̄→Wγ+X events utilizing data corresponding to 0.7fb-1 of integrated luminosity at s=1.96TeV collected by the D0 detector at the Fermilab Tevatron Collider. We set limits on anomalous WWγ couplings at the 95% C.L. The one-dimensional 95% C.L. limits are 0.49<κγ<1.51 and -0.12<λγ<0.13. We make the first study of the charge-signed rapidity difference between the lepton and the photon and find it to be indicative of the standard model radiation-amplitude zero in the Wγ system. © 2008 The American Physical Society.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work we studied the changes of the optical constants of films in the binary system Sb2O3-Sb2S3 induced by light in the VIS-UV. The measurements were performed before and after homogeneous irradiation of the films to a Hg lamp and in real time during the holographic exposure of the samples (at 458nm). Changes of the absorption coefficient (amplitude grating) and refractive index (phase grating) were measured simultaneously using the self-diffraction using the holographic setup. Besides the films presented a strong photodarkening effect under homogeneous irradiation, the samples holographically exposed presented only refractive index modulations. None amplitude modulation was measured in real time for spatial frequencies of about 1000 l/mm. © 2009 SPIE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Using the results recently obtained for computing integrals over (non-minimal) pure spinor superspace, we compute the coefficient of the massless two-loop four-point amplitude from first principles. Contrasting with the mathematical difficulties in the RNS formalism where unknown normalizations of chiral determinant formulæ force the two-loop coefficient to be determined only indirectly through factorization, the computation in the pure spinor formalism can be smoothly carried out. © SISSA 2010.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper proposes a novel differential mixer topology. The traditional stage of switching is replaced by a stack of NMOS and PMOS transistors combined. A design is given of a 900 MHz down-conversion mixer using a 0.35 μm CMOS process. Comparison with conventional mixer shows that the topology leads to a better performance in terms of conversion gain and linearity. ©2012 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Ciências Biológicas (Biologia Vegetal) - IBRC

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUÇÃO: A determinação dos domínios de intensidade de exercício tem importantes implicações na prescrição do treino aeróbio e na elaboração de delineamentos experimentais. OBJETIVO: Analisar os efeitos do nível de aptidão aeróbia sobre a amplitude dos domínios de intensidade de exercício durante o ciclismo. MÉTODOS: Doze ciclistas (CIC), 11 corredores (COR) e oito indivíduos não treinados (NT) foram submetidos aos seguintes protocolos em diferentes dias: 1) teste progressivo para determinação do limiar de lactato (LL), consumo máximo de oxigênio (VO2máx) e sua respectiva intensidade (IVO2máx); 2) três testes de carga constante até a exaustão a 95, 100 e 110% IVO2máx para a determinação da potência crítica (PC); 3) testes até a exaustão para determinar a intensidade superior do domínio severo (Isup). As amplitudes dos domínios (moderado < LL; LL > pesado < PC; PC > severo < Isup) foram expressas como percentual da Isup (VO2). RESULTADOS: A amplitude do domínio moderado foi similar entre CIC (52 ± 8%) e COR (47 ± 4%) e significantemente maior no CIC em relação ao NT (41 ± 7%). O domínio pesado foi significantemente menor no CIC (17 ± 6%) em relação ao COR (27 ± 6%) e NT (27 ± 9%). Em relação ao domínio severo não foram encontradas diferenças significantes entre os CIC (31 ± 7%), COR (26 ± 5%) e NT (31 ± 7%). CONCLUSÃO: O domínio pesado de exercício é mais sensível a mudanças determinadas pelo nível de aptidão aeróbia, existindo a necessidade de que se atenda ao princípio da especificidade do movimento, quando se pretende obter um elevado grau de adaptação fisiológica.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)