246 resultados para Accomplishment
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Dental trauma is more common in young patients and its sequelae may impair the establishment and accomplishment of an adequate treatment plan. This paper reports a case of complicated crown-root fracture in a young adult that was treated using adhesive tooth fragment reattachment and orthodontic root extrusion. Considering the time elapsed to follow up, the fracture extension, the amount of remaining root portion and the patient's low socioeconomic status, the treatment approach proposed for this case provided good functional and aesthetic outcomes. Clinical and radiographic results after 2 years were successful. This case report demonstrates the importance of establishing a multidisciplinary approach for a successful dental trauma management.
Resumo:
Objectives: the purpose of this study was to investigate the penetration of a conventional adhesive material into enamel bleached with 16% carbamide peroxide and 38% hydrogen peroxide using optical light microscopy.Methods: Extracted human teeth were randomly divided into eight experimental groups with six specimens each, according to the bleaching material and time interval after bleaching and before the bonding procedure. Groups were designated as follows: control group, restorations in unbleached teeth; restorations performed immediately after bleaching; restorations performed 7 days after bleaching; restorations performed 14 days after bleaching; and restorations performed 30 days after bleaching. The length of resin tags was measured with an Axiophot photomicroscope at 400x magnification for the calculation of the proportion of tags of study groups compared to the respective control groups. Analysis of variance was applied for comparison between groups; data were transformed into arcsine (p < 0.05).Results: the specimens of experimental groups, in which restorations were performed 7, 14, and 30 days after bleaching, showed better penetration of adhesive material into enamel than specimens restored immediately after bleaching. There was no statistically significant difference between the bleaching materials employed or in the interaction between bleaching agent and time interval.Conclusions: This suggests that a time interval of at least 7 days should be allowed between enamel bleaching and placement of adhesive bonding agents for accomplishment of composite resin restorations.
Resumo:
O objetivo desta pesquisa foi caracterizar os elementos físicos da bacia do córrego Santo Antônio, buscando compreender a influência que a área de entorno dessa bacia exerce sobre a Floresta Estadual Edmundo Navarro de Andrade (FEENA). Para isto, foram elaboradas as cartas geomorfológica e de uso do solo, além da compilação de dados geológicos, pedológicos e climáticos. Essa influência foi avaliada em termos da dinâmica de remobilização de materiais provenientes das nascentes, que não pertencem a FEENA, e que se constituem, portanto, em área de uso agrícola. A análise das características físicas indicou que essa área é susceptível a ação dos processos morfogenéticos e que estes foram intensificados e acelerados pelo uso do solo ao redor das nascentes. Verifica-se, assim, a necessidade de se reavaliar esse uso e de se fiscalizar o cumprimento da própria legislação ambiental, no que se refere ao uso e ocupação do território, em fundos de vale.
Resumo:
O objetivo deste trabalho foi verificar quanto tempo após a realização da enxertia hipocotiledonar ocorre a soldadura ou adesão entre enxerto e porta-enxerto, e também a formação da ponte de calo, verificada pelo total preenchimento da fenda por tecido meristemático secundário (calo). Foram produzidas 56 mudas de maracujazeiro-amarelo (Passiflora edulis Sims f. flavicarpa Deg.) pela enxertia hipocotiledonar em fenda cheia no topo sobre dois porta-enxertos (P. edulis Sims f. flavicarpa Deg. e P. alata Dryander). Aos 0, 3, 6, 9, 12, 15 e 18 dias após a enxertia, coletou-se a região da enxertia de quatro mudas de cada combinação. O material coletado foi fixado em solução de glutaraldeído a 3%, pós-fixado em tetróxido de ósmio a 2%, desidratado em uma série de álcool etílico (30, 40, 50, 60, 70, 80, 90, 100%), levado ao secador de ponto crítico (CO2), montado, metalizado com ouro - paládio (35 nm) e, por fim, observados e eletromicrografados em microscópio eletrônico de varredura JEOL JSM 5410 (operado em 15 kV). Verificou-se que, aos seis dias após a enxertia, a soldadura para o porta-enxerto Passiflora alata já havia ocorrido, o que só foi constatado para Passiflora edulis f. flavicarpa aos nove dias. Também, aos nove dias, observou-se para ambos os porta-enxertos a completa formação da ponte de calo, indicando que, a partir daí, pode-se iniciar o processo de aclimatação da muda, para levá-la a um ambiente de menor umidade.
Resumo:
As normas oficiais para análise de sementes não estabelecem critérios para a execução de testes de germinação da maioria das espécies florestais. Assim, o objetivo deste trabalho foi a determinação do substrato, da temperatura e da necessidade de superação da dormência das sementes para o teste de germinação de Stryphnodendron adstringens. Foram avaliados o tratamento de escarificação com ácido sulfúrico por 60 min, os substratos vermiculita, rolo de papel, areia e solo e as temperaturas constantes de 20, 25, 30 e 35 ºC e alternadas de 15-35 ºC e 20-30 ºC, utilizando-se a primeira contagem de germinação (7 dias) e a porcentagem de plântulas normais, anormais, sementes mortas e dormentes (42º dia após a semeadura) com quatro repetições de 50 sementes. As sementes de S. adstringens devem ser submetidas ao teste de germinação, após superação da dormência, em substrato papel e nas temperaturas constantes de 25, 30 ou 35 ºC ou alternadas de 20-30 ºC.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Para a realização desta pesquisa, foram coletados vinte fetos fêmeas em diferentes fases de gestação da raça Nelore. Os cornos uterinos e as tubas uterinas foram dissecados, mensurados e os fragmentos fixados em paraformaldeído tamponado a 4,00%, processados e incluídos em paraplástico. Os cortes com 5 mm foram corados com hematoxilina e eosina, tricrômio de Masson (para fibras colágenas), Verhoeff (para fibras elásticas) e com reticulina (para fibras reticulares). Os resultados mostraram que não há diferença significativa das mensurações entre os lados direito e esquerdo para os cornos uterinos e tubas uterinas, porém há correlação entre os valores obtidos das mensurações dos órgãos em função da idade dos fetos, ou seja, o crescimento dos órgãos acompanha o crescimento fetal. O epitélio de revestimento do útero não apresenta variações morfológicas evidentes no período analisado. A partir de 23 semanas de gestação, a mucosa uterina apresenta evolução marcante no desenvolvimento das projeções e não há aparecimento de glândulas endometriais na parede uterina no período analisado. A camada muscular apresenta a subcamada circular interna desenvolvida até 23 semanas de gestação e a partir de 24 semanas há presença das duas subcamadas. A camada serosa é típica e não mostra variabilidade no decorrer da gestação. As tubas uterinas apresentam diferenças de crescimento, principalmente dos pregueamentos que a partir de 23 semanas de gestação tornaram-se mais altos e ramificados, porém sem aparecimento de pregas terciárias. Com o desenvolvimento fetal, os cílios epiteliais do pregueamento tubárico são maiores em tamanho e em número. Até 32 semanas de gestação, a camada muscular das tubas uterinas apresenta apenas a subcamada circular interna. A camada serosa e o mesosalpinge são típicos e não apresentam variações importantes. As variações mais marcantes para os órgãos estudados ocorreram a partir de 23 semanas de gestação.
Resumo:
This study evaluated the microleakage of pit and fissure sealants after different surface preparation (invasive technique and laser irradiation) and the use of different materials (fluoride resin-filled sealant, resin-modified glass ionomer cement and adhesive system). Eighty-four pre molars were used in this study, which were divided into seven groups. After the accomplishment of the different treatments, these were submitted to thermocycling process and assess for microleakage by examination under an epifluorescent microscope and scored zero to seven. Two specimens of each group were observed under scanning electron microscope (SEM). The results showed that laser irradiation did not lessen microleakage in pit and fissures when using a filled-resin sealant with fluoride or a resin-modified glass ionomer cement. The use of laser irradiation and adhesive system, followed by a resin-filled sealant with fluoride, showed the lowest microleakage scores in pit and fissures. Comparing this group to the resin-modified glass ionomer cement group, there was statistical significance. The use of a adhesive system decreased microleakage when using a fluoride resin-filled sealant with or without previous laser irradiation; although it was not statistically significant.
Resumo:
Restorative dentistry has been increasingly concerned with preservation of the dental structure. For that reason, ultraconservative cavity preparations have been performed with air abrasion systems. The aim of this study was to present treatment options for the occlusal surface of first permanent molars with employment of the conventional method and the air abrasion system for accomplishment of the cavity preparation and a composite occlusal matrix for an accurate reproduction of the tooth surface.
Resumo:
Even though fluoride provides a significant contribution in dental caries prevention, it is known that its random employment may lead to enamel alterations such as dental fluorosis, besides the possibility of severe systemic alterations. The aim of this study was to evaluate the ingestion of mouthwashes administered to preschool children. It was concluded that parents and teachers of young children must be very careful during the accomplishment of educational programs comprising fluoridated mouthwashes, because of the high possibility of ingestion.
Resumo:
The purpose of this study was to employ photographic evaluation to observe the presence or absence of bubbles in pit and fissure sealants Concise and Prisma Shield, at 7 days, 18 months, 36 months and 11 years after accomplishment of treatment. Methods: A hematoxylin-based staining solution was applied to the occlusal surface at the study periods, which allowed assessment of the sealing material on the surface. All occlusal surfaces were photographed and the photographs corresponding to each period were subjected to photographic evaluation. Results: There was statistically significant difference only at 18 months, with a significantly higher number of specimens with bubbles for the Prisma Shield sealant compared to the Concise, whereas the groups were similar at all other study periods. On the other hand, separate analysis of subsequent periods of the sealants did not reveal any significant difference. Conclusions: According to the results of the present longitudinal investigation, it may be concluded that the sealing materials showed that bubbles came into and went out with time. However, this fact did not interfere with its clinical purpose, provided the remaining material covers the expected region of pits and fissures.
Resumo:
Purpose: to compare in a retrospective way, 51 women who underwent tubal ligation, 30 through microlaparoascopy (Gmicrol) and 21 through minilaparotomy (Gminil). Methods: the analyzed parameters were: total time for accomplishment of the procedure and the surgical technique, time of hospital stay and return to the habitual activities after the surgery, postoperative pain, morbidity, satisfaction degree and esthetic effect, considering values of p<0,05 as significant, and also standard cost. Results: Gmicrol took less time to accomplish the surgery than the Gminil (43 against 57 minutes respectively, p<0,05), less time to accomplish the surgical technique (6.48 against 30.32 minutes respectively, p<0,05), and lower hospital stay (9,90 hours as against 41,7 hours respectively, p <0,05). There was no significant difference between the two groups regarding time to return to the habitual activities after surgery. To evaluate postoperative pain, a scale of 0-10 it was applied. Gmicrol present a lower pain score on the 1st and 2nd postoperative days (1.13 and 0.26 to Gmicrol and 4.52 and 1.14 to Gminil, respectively, p<0,05). There was no significant difference between immediate postoperative the most common complaint being pain at the site of pain and that on the 3rd postoperative day. Gminil presented a higher morbidity rate incision. To evaluate the satisfaction degree and esthetic effect, numeric values were attributed to as good, regular, poor and very bad as answered by the patiets. Gmicrol presented a higher satisfaction degree (p<0,05) and better esthetic effect as compared to Gminil (p <0,05). The microlaparoscopy standard cost was R$ 109.30 being lower than that of minilaparotomy. Conclusions: tubal ligation by microlaparoscopy, under local anesthesia and conscious sedation presented some advantages compared to minilaparotomy.
Resumo:
This paper presents two discrete sliding mode control (SMC) design. The first one is a discrete-time SMC design that doesn't take into account the time-delay. The second one is a discrete-time SMC design, which takes in consideration the time-delay. The proposed techniques aim at the accomplishment simplicity and robustness for an uncertainty class. Simulations results are shown and the effectiveness of the used techniques is analyzed. © 2006 IEEE.
Resumo:
This study carried out an in vitro evaluation and comparison of the occurrence of marginal leakage in bonded restorations using mechanical or chemical-mechanical (Carisolv) removal of carious tissue. For that purpose, 40 extracted decayed human molars were divided into 4 groups: GI (burs + Prime & Bond NT + TPH), GII (Carisolv + Prime & Bond NT + TPH), GIII (burs + SBMP + Z100) and GIV (Carisolv + SBMP + Z100). After accomplishment of the restorations and thermal cycling, the teeth were exposed to dye, sectioned and qualitatively evaluated. The results demonstrated that the system of removal of carious tissue did not influence the results of microleakage at any of the cavity margins. At dentinal margins, use of the Prime & Bond NT + TPH restorative system allowed the occurrence of less microleakage than the SBMP + Z100 system.