37 resultados para AVERAGE POWER


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Linear resonant harvesters have been the most common type of generators used to scavenge energy from mechanical vibrations. When subject to harmonic excitation, good performance is achieved once the device is tuned so that its natural frequency coincides with the excitation frequency. In such a situation, the average power harvested in a cycle is proportional to the cube of the excitation frequency and inversely proportional to the suspension damping, which is sought to be very low. However, a very low damping involves a relatively long transient in the system response, where the classical formulation adopted for steady-state regimes do not hold. This paper presents an investigation into the design of a linear resonant harvester to scavenge energy from time-limited harmonic excitations involving a transient response, which could be more likely in some practical situations. An application is presented considering train-induced vibrations.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Pós-graduação em Bases Gerais da Cirurgia - FMB

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This article discusses an ergonomic analysis of the controls used by tractor operators, covering their positions in relation to the casing of your job. Was performed an assessment of the controls of the job of a model NH 7630 tractor average power of 74 kW (100 CV), using the norms of the ABNT. With this screening could detect the positive and negative. Then was accomplished an analytical study of the controls. Evaluation results show that some controls of tractors have errors evaluated in relation to NBR/ ISO 6682.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Anaerobic efforts are commonly required through repeated sprint during efforts in many sports, making the anaerobic pathway a target of training. Nevertheless, to identify improvements on such energetic way it is necessary to assess anaerobic capacity or power, which is usually complex. For this purpose, authors have postulated the use of short running performances to anaerobic ability assessment. Thus, the aim of this study was to find a relationship between running performances on anaerobic power, anaerobic capacity or repeated sprint ability. Methods Thirteen military performed maximal running of 50 (P50), 100 (P100) and 300 (P300) m on track, beyond of running-based anaerobic sprint test (RAST; RSA and anaerobic power test), maximal anaerobic running test (MART; RSA and anaerobic capacity test) and the W′ from critical power model (anaerobic capacity test). Results By RAST variables, peak and average power (absolute and relative) and maximum velocity were significantly correlated with P50 (r = −0.68, p = 0.03 and −0.76, p = 0.01; −0.83, p < 0.01 and −0.83, p < 0.01; and −0.78, p < 0.01), respectively. The maximum intensity of MART was negatively and significantly correlated with P100 (r = −0.59) and W′ was not statistically correlated with any of the performances. Conclusion MART and W′ were not correlated with short running performances, having a weak performance predicting probably due to its longer duration in relation to assessed performances. Observing RAST outcomes, we postulated that such a protocol can be used during daily training as short running performance predictor.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The purpose of this study is to characterize the geological subsurface structure of the diabase sill of the Paraná Magmatic Province intruded in the Itararé Group, located near the city of Limeira, in the east-central region of São Paulo state. The magnetometric method served as an important tool defining the igneous body in view of the great contrast between the physical properties of the diabase sill and the host sandstones. Previous cartographic data signaled in region a possible lateral continuity in subsurface, of the various sills that occur in the region. However, the magnetic data obtained herein indicate that the area of occurrence of this body is very restricted and independent of the others observed in the region. The analysis of the radial average power spectrum obtained allowed determine the interval of number of waves adequate for the separation of shallow and deep sources, and thus conclude that the sill of the Limeira region is located more than 100 m deep.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The sunflower oleaginous is the fourth of recognized importance in the oil production and few studies related to agricultural operations adopted for this crop. The objective of the present work was to study the performance of agricultural machines in the conventional tillage and reduced in the plantation of the sunflower crop. The experiment was installed at the Experimental Farm of Lageado, belonging to the Faculty of Agricultural Sciences of UNESP, located in Botucatu-SP. It consisted of two types of tillage (conventional tillage-CC and reduced tillage-CR), with experimental design in randomized blocks and four replications. The treatment CC promoted less coverage of the soil surface protected with waste when compared to CR treatment. The chisel plow was the tillage of equipment that required the tractor higher average traction force, average power traction and slippage, consequently, promoted lower average speed of work. The theoretical field capacity and area of land involved in the treatment CR were superior when compared to treatment CC, thereby lower consumption of fuel per hour worked was lower in CR treatment.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Forage sorghum can be grown in areas and environmental conditions dry and warm, where the productivity of other forage plants can often be uneconomical. The soil disturbance can be made only on the lines of planting (direct seeding) or entirely from the area for seeding (conventional tillage), as plowing, harrowing, subsoiling and chiseling (minimum tillage). The displacement speed ideal for planting is one in which the groove is opened and closed without removing the over-ground, allowing the distribution of seed spacing and depth constant. The experiment was conducted in a soil classified as Typic Oxisol at Lageado Experimental Farm, Faculty of Agronomic Sciences, UNESP, Botucatu campus. This study aimed to evaluate the response of sorghum in four forward speeds (3, 5, 6 and 9 km h-1) and four systems of soil management: SD (direct seeding), GP (harrow + sowing), LPG (disc harrow and two light disking + sowing) and CR (scarification and seeding). Data was subjected to analysis of variance in a factorial 4 x 4 and a randomized block design with split plots. The following parameters were determined: average speed, average strength of the drawbar, the average power drawbar, theoretical field capacity of the tractor-equipment, fuel consumption per hour. For the conditions under which the experiment was conducted, it was concluded that the hourly fuel consumption was not influenced by tillage systems and was inversely proportional to the increase of speed work, and that the change of speed in the sowing operation did not provide additional the values of average traction force on the bar of the tractor-planter.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents a novel single-phase high-power-factor (HPF) pulsewidth-modulated (PWM) boost rectifier featuring soft commutation of the active switches at zero current (ZC), It incorporates the most desirable properties of conventional PWM and soft-switching resonant techniques.The input current shaping is achieved with average current mode control and continuous inductor current mode.This new PWM converter provides ZC turn on and turn off of the active switches, and it is suitable for high-power applications employing insulated gate bipolar transistors (IGBT's),The principle of operation, the theoretical analysis, a design example, and experimental results from a laboratory prototype rated at 1600 W with 400-Vdc output voltage are presented. The measured efficiency and the power factor were 96.2% and 0.99%, respectively, with an input current total harmonic distortion (THD) equal to 3.94%, for an input voltage with THD equal to 3.8%, at rated load.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A Summary of different topological arrangements concerning a ZCS-PWM cell is presented, based on the analysis of its application in boost rectifying preregulators, controlled by the technique of instantaneous average values of input current, with the purpose of obtaining high-input-power-factor rectifier and high efficiency in single-phase applications in telecommunication systems. The main characteristics of each switching cell are described, providing conditions to establish a qualitative comparison among the structures. In addition, experimental results are presented for a prototype of the latest version of the ZCS-PWM boost rectifier, implemented for processing normal values of 1200 W output power and 400 V output average voltage, at 220 V Input RMS voltage and 50 kHz switching frequency.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper introduces novel zero-current-switching (ZCS) pulsewidth-modulated (PWM) preregulators based on a new soft-commutation cell, suitable for insulated gate bipolar transistor applications. The active switches in these proposed rectifiers turn on in zero current and turn off in zero current-zero voltage. In addition, the diodes turn on in zero voltage and their reverse-recovery effects over the active switches are negligible. Moreover, based on the proposed cell, an entire family of de-to-de ZCS-PWM converters can be generated, providing conditions to obtain naturally isolated converters, for example, derived buck-boost, Sepic. and Zeta converters. The novel ac-to-dc ZCS-PWM boost and Zeta preregulators are presented in order to verify the operation of this soft-commutation cell, In order to minimize the harmonic contents of the input current, increasing the ac power factor, the average-current-mode control is used, obtaining preregulators with ac power factor near unity and high efficiency at wide load range. The principle of operation, theoretical analysis, design example, and experimental results from test units for the novel preregulators are presented. The new boost preregulator was designed to nominal values of 1.6 kW output power, 220 V(rms) input voltage, 400 V(dc) output voltage, and operating at 20 kHz. The measured efficiency and power factor of the new ZCS-PWM boost preregulator were 96.7% and 0,99, respectively, with an input current total harmonic distortion (THD) equal to 3.42% for an input voltage with THD equal to 1.61%, at rated load, the new ZCS-PWM Zeta preregulator was designed to voltage step-down operation, and the experimental results were obtained from a laboratory prototype rated at 500 W, 220 V(rm), input voltage, 110 V(dc) output voltage, and operating at 50 kHz. The measured efficiency of the new ZCS-PWM Zeta preregulator is approximately 96.9% and the input power factor is 0.98, with an input current THD equal to 19.07% while the input voltage THD is equal to 1.96%, at rated load.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents a dimmable electronic ballast designed for multiple fluorescent lamps applications. A ZCS-PWM Boost rectifier and a classical resonant Full-Bridge inverter compose this new electronic ballast, providing conditions for the obtaining of high input power-factor, and soft-switching processes for all semiconductor devices employed in the structure. The instantaneous average input current control technique is employed in the Boost rectifier. Concerning the Full-Bridge inverter, it is controlled by the imposition of phase-shift in the current processed through the sets of resonant filters + lamps, according to an adaptation in a specially designed control IC, called IR2159. Experimental results are presented in order to validate the analyses developed in this paper.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study was to test if the critical power model can be used to determine the critical rest interval (CRI) between vertical jumps. Ten males performed intermittent countermovement jumps on a force platform with different resting periods (4.1 +/- 0.3 s, 5.0 +/- 0.4 s, 5.9 +/- 0.6 s). Jump trials were interrupted when participants could no longer maintain 95% of their maximal jump height. After interruption, number of jumps, total exercise duration and total external work were computed. Time to exhaustion (s) and total external work (J) were used to solve the equation Work = a + b . time. The CRI (corresponding to the shortest resting interval that allowed jump height to be maintained for a long time without fatigue) was determined dividing the average external work needed to jump at a fixed height (J) by b parameter (J/s). in the final session, participants jumped at their calculated CRI. A high coefficient of determination (0.995 +/- 0.007) and the CRI (7.5 +/- 1.6 s) were obtained. In addition, the longer the resting period, the greater the number of jumps (44 13, 71 28, 105 30, 169 53 jumps; p<0.0001), time to exhaustion (179 +/- 50, 351 +/- 120, 610 +/- 141, 1,282 +/- 417 s; p<0.0001) and total external work (28.0 +/- 8.3, 45.0 +/- 16.6, 67.6 +/- 17.8, 111.9 +/- 34.6 kJ; p<0.0001). Therefore, the critical power model may be an alternative approach to determine the CRI during intermittent vertical jumps.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)