69 resultados para ARL profiles


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objectives of this study were to determine the efficacy of recombinant equine luteinizing hormone (reLH) in shortening the time to ovulation in cycling mares and to determine the effects of treatment on endogenous hormones and inter-ovulatory intervals. In study 1, mares of light horse breeds (3-20 years) were treated with either a vehicle, various doses of reLH, or human chorionic gonadotropin (hCG). Cycling mares were examined by palpation and ultrasound per rectum daily or every 12 h from the time of treatment to ovulation. In studies 2 and 3, jugular blood samples were collected daily or every 12 h from the time of treatment to ovulation for analysis of LH, follicle stimulating hormone (FSH), estradiol-17 beta (E-2), and progesterone (P-4) by radioimmunoassays (RIA). Increasing doses of reLH (0.3, 0.6, 0.75, and 0.9 mg) showed increasing effectiveness at inducing ovulation within 48 h of treatment. Treatments with the 0.75 and 0.9 mg doses of reLH resulted in 90% and 80% ovulation rates, which were similar to hCG treatment (85.7%). Except for the early rise in LH after treatment with 0.5, 0.65, and 1.0 mg of reLH, hormone profiles appeared to be similar between control and treated cycles. Inter-ovulatory intervals were similar between control and treatment cycles. In conclusion, reLH is a reliable and effective ovulatory agent that does not significantly alter endogenous hormone profiles or affect inter-ovulatory intervals.(c) 2007 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The molecular and ultrastructural profiles of the symbionts found in the midgut and ileum of Cephalotes atratus, Cephalotes clypeatus, and Cephalotes pusillus were determined using the V3 region of the bacterial 16S rDNA gene and transmission electron microscopy (T.E.M.). Two samples of C atratus, three of C clypeatus, and six of C. pusillus were analyzed. The coefficients of similarity ranged from 80% to 94% for the samples of symbionts from C. clypeatus and C. atratus, despite being collected in geographically distant sites. The variability within symbionts found in the samples of C. pusillus varied from 29% to 55%, in samples geographically close as well as distant. PCR-DGGE was effective for the purpose of this study and can be considered a versatile tool to analyze gut microbiota. Details of the ultrastructural aspect of these bacteria are presented. (C) 2010 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Total and individual carotenoid concentrations were determined by spectro photometry and HPLC, in raw tubers of a sample of 23 accessions of Solanum phureja potatoes taken at random from the world germplasm collection following its stratification on tuber flesh color. Lutein, zeaxanthin, violaxanthin, antheraxanthin and beta-carotene were detected in all accessions and three distinct patterns of carotenoid accumulation were evidenced by cluster analysis. Accessions in group 1 showed the highest concentrations of total carotenoids (1258-1840 mu g 100 g(-1) FW) comprised largely of zeaxanthin (658-1290 mu g 100 g(-1) FW) with very low or no presence of beta-carotene (below 5.4 mu g 100 g(-1) FW). Accessions in group 2 presented moderate total carotenoid concentrations with violaxanthin, antheraxanthin, lutein and zeaxanthin as the major carotenoids. Accessions in group 3 showed low concentrations of total carotenoids (97-262 mu g 100 g(-1) FW) and very low or no zeaxanthin, with lutein and violaxanthin as the predominant carotenoids and relatively high concentrations of beta-carotene(up to 27 mu g 100 g(-1) FW). Five accessions with significant concentrations of zeaxanthin were identified with the accession 703566 showing the highest concentration (1290 p g 100 g(-1) FW). This value is to our knowledge higher than any value previously reported for potatoes, including those achieved through genetic modification. For the 23 S. phureja accessions, total carotenoid concentration was positively and significantly correlated with antheraxanthin and zeaxanthin concentrations, and negatively and significantly correlated with beta-carotene concentration. (C) 2008 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Several Brazilian commercial gasoline physicochemical parameters, such as relative density, distillation curve (temperatures related to 10%, 50% and 90% of distilled volume, final boiling point and residue), octane numbers (motor and research octane number and anti-knock index), hydrocarbon compositions (olefins, aromatics and saturates) and anhydrous ethanol and benzene content was predicted from chromatographic profiles obtained by flame ionization detection (GC-FID) and using partial least square regression (PLS). GC-FID is a technique intensively used for fuel quality control due to its convenience, speed, accuracy and simplicity and its profiles are much easier to interpret and understand than results produced by other techniques. Another advantage is that it permits association with multivariate methods of analysis, such as PLS. The chromatogram profiles were recorded and used to deploy PLS models for each property. The standard error of prediction (SEP) has been the main parameter considered to select the "best model". Most of GC-FID-PLS results, when compared to those obtained by the Brazilian Government Petroleum, Natural Gas and Biofuels Agency - ANP Regulation 309 specification methods, were very good. In general, all PLS models developed in these work provide unbiased predictions with lows standard error of prediction and percentage average relative error (below 11.5 and 5.0, respectively). (C) 2007 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A partir de perfis populacionais experimentais de linhagens do díptero forídeo Megaselia scalaris, foi determinado o número mínimo de perfis amostrais que devem ser repetidos, via processo de simulação bootstrap, para se ter uma estimativa confiável do perfil médio populacional e apresentar estimativas do erro-padrão como medida da precisão das simulações realizadas. Os dados originais são provenientes de populações experimentais fundadas com as linhagens SR e R4, com três réplicas cada, e que foram mantidas por 33 semanas pela técnica da transferência seriada em câmara de temperatura constante (25 ± 1,0ºC). A variável usada foi tamanho populacional e o modelo adotado para cada perfíl foi o de um processo estocástico estacionário. Por meio das simulações, os perfis de três populações experimentais foram amplificados, determinando-se, dessa forma, o tamanho mínimo de amostra. Fixado o tamanho de amostra, simulações bootstrap foram realizadas para construção de intervalos de confiança e comparação dos perfis médios populacionais das duas linhagens. Os resultados mostram que com o tamanho de amostra igual a 50 inicia-se o processo de estabilização dos valores médios.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Air flow through packed beds was analyzed experimentally under conditions ranging from those that reinforce the effect of the wall on the void fraction to those that minimize it. The packing was spherical particles, with a tube-to-particle diameter ratio (D/dp) between 3 and 60. Air flow rates were maintained between 1.3 and 4.44 m3/min, and gas velocity was measured with a Pitot tube positioned above the bed exit. Measurements were made at various radial and angular coordinate values, allowing the distribution of air flow across the bed to be described in detail. Comparison of the experimentally observed radial profiles with those derived from published equations revealed that at high D/dp ratios the measured and calculated velocity profiles behaved similarly. At low ratios, oscillations in the velocity profiles agreed with those in the voidage profiles, signifying that treating the porous medium as a continuum medium is questionable in these cases.