24 resultados para AIRWAYS: negative pressure
Resumo:
A simultaneous method for the trace determination of acidic, neutral herbicides and their transformation products in estuarine waters has been developed through an on-line solid-phase extraction method followed by liquid chromatography with diode array and mass spectrometric detection. An atmospheric pressure chemical ionization (APCI) interface was used in the negative ionization mode after optimization of the main APCI parameters. Limits of detection ranged from 0.1 to 0.02 ng/ml for 50 mi of acidified estuarine waters preconcentrated into polymeric precolumns and using time-scheduled selected ion monitoring mode. Two degradation products of the acidic herbicides (4-chloro-2-methylphenol and 2,4-dichlorophenol) did not show good signal response using APCI-MS at the concentration studied due to the higher fragmentor voltage needed for their determination For molinate and the major degradation product of propanil, 3,4-dichloroaniline, positive ion mode was needed for APCI-MS detection. The proposed method was applied to the determination of herbicides in drainage waters from rice fields of the Delta del Ebro (Spain). During the S-month monitoring of the herbicides, 8-hydroxybentazone and 4-chloro-2-methylphenoxyacetic acid were successively found in those samples. (C) 2000 Elsevier B.V. B.V. All rights reserved.
Resumo:
Pressure drop and minimum fluidization velocity were experimentally studied in a vibro-fluidized bed of inert particles subjected to different vibration intensities during drying of soursop pulp. Maltodextrin was added to the pulp in order to prevent stickiness between particles and the consequent bed collapse. Pulps were initially concentrated, resulting in pastes with different soluble solids content, and a constant fraction of maltodextrin was guaranteed in the final pulp samples. The pulp theological behavior as affected by temperature and total soluble solids content, including maltodextrin, was evaluated and the effect of pulp apparent viscosity on pressure drop and minimum vibro-fluidization velocity were investigated. Two types of inert particles -3.6 mm glass beads and 3 mm Teflon cylinders (length and diameter) - were tested and, due to lower pressure drop presented by Teflon cylinders during operation of the dry vibro-fluidized bed, these particles were adopted for pulp drying process. Increasing pulp apparent viscosity caused a considerable increase in the vibro-fluidized bed pressure drop during pulp drying and, as a consequence resulted in a larger value of minimum vibro-fluidization velocity. on the other hand, the negative effect of increasing apparent viscosity could be attenuated by increasing the fluidized bed vibration intensity, which could prevent stickiness between particles. (c) 2006 Elsevier B.V. All rights reserved.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Objective: The present study was performed to investigate the influence of different routes of perfusion on the distribution of the preservation solutions in the lung parenchyma and upper airways. Methods: Pigs were divided into four groups: control (n = 6), pulmonary artery (PA) (n = 6), simultaneous PA + bronchial artery (BA) (n = 8), and retrograde delivery (n = 6). After preparation and cannulation, cardioplegia solution and Euro- Collins solution (ECS) for lung preservation were given simultaneously. After removal of the heart, the double lung bloc was harvested. Following parameters were assessed: total and regional perfusion (dye-labeled microspheres), tissue water content, PA, aorta, left atrial and left ventricular pressures, cardiac output and lung temperature. Results: Our data show that flow of the ECS in lung parenchyma did not reach control values (9.4 ± 1.0 ml/min per g lung wet weight) regardless of the route of delivery (PA 6.3 ± 1.5, PA + BA 4.8 ± 0.9, retrograde 2.7 ± 0.9 ml/min per g lung wet weight). However, flow in the proximal and distal trachea were significantly increased by PA + BA delivery (0.970 ± 0.4, respectively, 0.380 ± 0.2 ml/min per g) in comparison with PA (0.023 ± 0.007, respectively, 0.024 ± 0.070 ml/min per g), retrograde (0.009 ± 0.003, respectively, 0.021 ± 0.006 ml/min per g) and control experiments (0.125 ± 0.0018, respectively, 0.105 ± 0.012 ml/g per min). Similarly the highest flow rates in the right main bronchus were achieved by PA + BA delivery (1.04 ± 0.4 ml/min per g) in comparison with 0.11 ± 0.03 in control, 0.033 ± 0.008 in PA, and 0.019 ± 0.005 ml/min per g in retrograde group. Flows in the left main bronchus were 0.09 ± 0.02 ml/min per g in control, 0.045 ± 0.012 ml/min per g in PA, and 0.027 ± 0.006 ml/min per g in retrograde group. The flow rates were significantly (P = 0.001) increased by PA + BA delivery of the storage solution (0.97 ± 0.3 ml/min per g). Conclusions: Our data show that the distribution of ECS for lung preservation is significantly improved in airway tissues (trachea and bronchi) if a simultaneous PA + BA delivery is used.
Resumo:
We studied a nonconcurrent cohort of 582 patients admitted to a medical-surgical intensive care unit. Use of antimicrobials (imipenem and metronidazole) was a risk factor for acquisition of imipenem-resistant Acinetobacter baumannii only for the subcohort of patients admitted in months in which colonization pressure was lower than the median value. © 2013 by the Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.
Resumo:
Aim: To evaluate the sound pressure level to which preschool students are exposed. Method: This was a prospective, quantitative, nonexperimental, and descriptive study. To achieve the aim of the study we used an audio dosimeter. The sound pressure level (SPL) measurements were obtained for 2 age based classrooms. Preschool I and II. The measurements were obtained over 4 days in 8-hour sessions, totaling 1920 minutes. Results: Compared with established standards, the SPL measured ranged from 40.6 dB (A) to 105.8 dB (A). The frequency spectrum of the SPL was concentrated in the frequency range between 500 Hz and 4000 Hz. The older children produced higher SPLs than the younger ones, and the levels varied according to the activity performed. Painting and writing were the quietest activities, while free activities period and games were the noisiest. Conclusion: The SPLs measured at the preschool were higher and exceeded the maximum permitted level according to the reference standards. Therefore, the implementation of actions that aim to minimize the negative impact of noise in this environment is essential.
Resumo:
OBJETIVO:Revisar a literatura sobre estudos que estimaram a prevalência de pressão arterial elevada (PAE) ou hipertensão arterial sistêmica (HAS) em adolescentes brasileiros, considerando os procedimentos metodológicos empregados.MÉTODOS:Pesquisa bibliográfica de estudos de prevalência de PAE/HAS em adolescentes de 1995 a 2010. A busca foi realizada nas bases de dados eletrônicos PubMed/Medline, Lilacs, SciELO, Isi e Adolec. Foram utilizados os descritores: hipertensão, pressão arterial, adolescente, estudantes, estudos transversais, prevalência e Brasil, nas línguas portuguesa e inglesa. Além disso, foi elaborado um escore, baseado nas Recommendations for Blood Pressure Measurement in Humans and Experimental Animals e nas VI Diretrizes Brasileiras de Hipertensão, para a análise dos procedimentos utilizados para medida da PA nos estudos variando de 0 a 18.RESULTADOS:Foram identificados 21 artigos, a maioria publicada nos últimos 10 anos, sendo 90,5% realizados em base escolar e nas regiões sudeste, nordeste e sul do país. As prevalências de PAE/HAS variaram de 2,5 a 30,9%. A pontuação dos estudos variou de 0 a 16. Foi observada uma correlação negativa significante (rho = -0,504; p = 0,020) entre a prevalência de PAE/HAS e o escore da qualidade da medida da PA.CONCLUSÃO:A grande variabilidade das estimativas da PAE/HAS parece ser influenciada pelos procedimentos metodológicos utilizados nos estudos.
Resumo:
This study aims to evaluate and correlate the vascular, sensory and motor components related to the plantar surface in individuals with diabetic peripheral neuropathy. 68 patients were categorized into two groups: 28 in the neuropathic group and 40 in the control group. In each patient, we assessed: circulation and peripheral perfusion of the lower limbs; somatosensory sensitivity; ankle muscle strength; and pressure on the plantar surface in static, dynamic and gait states. We used the Mann-Whitney test and analysis of variance (ANOVA and MANOVA) for comparison between groups, and performed Pearson and Spearman linear correlations amongst the variables (P < 0.05). The somatosensory sensitivity, peripheral circulation and ankle muscle strength were reduced in the neuropathic group. In full peak plantar pressures, no differences were seen between groups, but differences did appear when the foot surface was divided into regions (forefoot, midfoot and hindfoot). In the static condition, the plantar surface area was greater in the neuropathic group. In the dynamic state, peak pressures in the neuropathic group, were higher in the forefoot and lower in the hindfoot, as well as lower in the hindfoot during gait. There were positive or negative correlations between the sensitivity deficit, dorsal ankle flexor strength, plantar surface area, and peak pressure by plantar region. The sensitivity deficit contributed to the increased plantar surface area.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)