67 resultados para AFFINE ROOT SYSTEMS
Resumo:
The termite problem in eucalyptus forest plantations in Brazil has been registered since 1908. The main termite pests can be separated in four groups: a) seedling/sapling termites; b) heartwood termites; c) bark termites and d) wood termites. The termites in the first group attack root and stalk bases of young eucalyptus plants. The most common species are Syntermes spp. and Cornitermes spp. and they are a serious obstacle to early eucalyptus developing. The heartwood termites attack formed trees destroying eucalyptus heartwood. Coptotermes testaceus is the most cited species in reports, but more species probably occur. Plant mortality caused by seedling/sapling termites vary of 10-70 %. There are not effective control methods to heartwood termites. The main seedling/sapling termite control strategy is the chemical barrier around root systems of plants. Nowadays, studies are being carried out to determine monitoring systems to termite infestations. Early results indicate that proportionally, few areas really need insecticide application, due to spatial distribution of termites to be aggregated. Therefore, it is necessary to develope techniques rationalizing insecticide utilization in eucalyptus plantations, to keep production systems feasible and to be suitable for environmental exigencies.
Resumo:
For the production of quality seedlings, depending on the physical characteristics of each substrate, more rational nutritional managements, from the of economic-environmental point of view, should be sought. This study aimed to evaluate the development and quality of Eucalyptus grandis × E. urophylla seedlings in terms of substrates and doses of controlledrelease Osmocote® fertilizer. The experiment was conducted with a completely randomized, factorial design, using as substrates: vermiculite+carbonized rice chaff+coconut fiber (1:1:1); vermiculite+coconut fiber (1:1) and vermiculite+coconut fiber (2:1) and doses of 2, 4, 6 and 8kg·m -3 of substrate. The substrates with higher water holding capacity allow seedlings to reach their maximum development in most parameters using lower doses of controlled-release fertilizer. We recommend the application of the controlled-release fertilizer at a dose of 6.0kg·m-3 in vermiculite+carbonized rice chaff+coconut fiber (1:1:1) and vermiculite+coconut fiber (2:1) substrates, and in substrate vermiculite+coconut fiber (1:1) at a dose of 7.0kg·m-3. In each substrate there is a dose range that promotes a greater formation of suitable root systems for planting in the field, which consequently results in seedlings with greater morphological development at nursery.
Resumo:
Pós-graduação em Ciências Biológicas (Genética) - IBB
Resumo:
Pós-graduação em Agronomia (Produção Vegetal) - FCAV
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Pós-graduação em Agronomia (Energia na Agricultura) - FCA
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Pós-graduação em Agronomia (Horticultura) - FCA
Resumo:
Introduction: The aim of this study was to compare the increase of the root canal area after instrumentation with EndoSequence or ProTaper rotary systems. Methods: Twenty-two mesial root canals from mandibular molars were instrumented. Teeth were mounted on a base, numbered, and divided into 2 groups; teeth from 1-11 (PT group) were instrumented by using the ProTaper system, and teeth from 12-22 (ES group) were instrumented by using the EndoSequence system. Cone beam computed tomography was performed on all teeth before and after instrumentation. Measurements at 3,5, and 7 mm as well as differences in instrument performance were statistically compared by the Student t test at 5% significance level. Results: Both systems increased significantly the root canal area (P < .05) at all levels. Comparison between the rotary systems showed significantly greater increase (P < .05) for EndoSequence at 3 mm, with no statistically significant difference (P < .05) at the other levels. Conclusions: Both rotary systems increased significantly the root canal area. (J Endod 2010;36:1179-1182)
Resumo:
Objective: the aim of this study was to evaluate the biomechanical preparation of flattened root canals using the following systems: Endo-Eze AET stainless steel oscillatory instruments (Ultradent) and RaCe rotary NiTi instruments (FKG Dentaire). Materials and Methods: Twenty extracted human mandibular incisors were randomly assigned to two groups: Group I Instrumentation with oscillatory Endo-Eze AET files (oscillatory technique); Group 2 - Instrumentation with rotary NiTi RaCe files (rotary technique). The teeth were decoronated, had their apices and coronal openings sealed with sticky wax and were embedded in crystal-clear orthophtalic polyester resin. The roots were sectioned transversally with diamond discs at 10 mm (middle third) and 5 mm (apical third) from the apex and the segments were reassembled for instrumentation. The sections were photographed before and after root canal instrumentation and evaluated with respect to whether the original root canal shape was modified by instrumentation. To evaluate the differences in the root canal shape before and after biomechanical preparation, scores were given regarding the instruments touch on the intracanal walls. Results: In middle third of the root canals instrumented with the rotary system, there was a change in the original canal anatomy (p < 0.05), with formation of a protuberance in the mesiodistal direction. This protuberance did not occur when the oscillatory instrumentation was used. The oscillatory system had better results in the middle and apical thirds as evaluated by Dunn's multiple-comparison test (p > 0.05). Conclusion: Under the tested conditions, Endo-Eze oscillatory system yielded the instrumentation of all flattened oot canal walls, maintaining the canal original shape throughout the biomechanical preparation, and was more effective than RaCe rotary system.
Resumo:
Objective. The aim of this in vitro study was to evaluate the interaction between two sources of fluoride (restorative systems and dentifrices) in inhibiting artificial root caries development. Methods. One hundred and eighty tooth segments were embedded in polyester resin, and sanded flat. Cylindrical cavities 1.0 mm-deep and 1.5 mm-diameter were prepared in root dentin and randomly restored by fluoride-containing restorative systems: Ketac-fil/Espe (Ke), Fuji II LC/GC Corp (Fj), F2000/3M (F2), Surefil/Dentsply (Su) or a control: Filtek Z250/3M (Z2). Ten experimental groups were made to test the association among the five restorative systems and two dentifrices: with F - (Sensodyne Baking Soda) or without F- (Sensodyne Original) (n = 18). After surface polishing, a 1 mm-wide margin around the restorations was demarcated and initial dentin surface Knoop microhardness values (KHNi) were obtained. The specimens were submitted to a pH-cycling model, and to applications of slurries of dentifrice. Afterwards the final dentin surface Knoop microhardness values (KHNf) were measured. Results. The differences between KHNi and KHNf, and the covariate KHNi were considered by the ANCOVA and Tukey's test (α = 0.05). The interaction between restorative system and dentifrice was statistically significant (p = 0.0026). All restorative systems provided some protection against artificial caries challenge when associated with the fluoride-containing dentifrice treatment. The means (standard deviation) of reductions in Knoop hardness values for systems associated with the fluoride-containing dentifrice were: Ke: 40.0(1.02)a, Fj: 41.9(1.02)b, F2: 43.3(1.04)c, Su: 43.5(1.00)c, Z2: 44.0(1.02)c; and with the non-fluoride-containing dentifrice were: Ke: 42.9(1.02)a, Fj: 44.7(1.01)b, F2: 45.2(1.09)bc, Su: 46.0(0.99)c, Z2: 46.6(0.99)c (statistical differences were expressed by different letters). Conclusion. The cariostatic effect shown by the fluoride-containing dentifrice could enhance that shown by Ketac-fil and Fuji II LC, and could mask that shown by F2000. © 2002 Elsevier Science Ltd. All rights reserved.