70 resultados para 622.3422
Resumo:
We assessed the 6-min walk distance (6MWD) and body weight x distance product (6MWw) in healthy Brazilian subjects and compared measured 6MWD with values predicted in five reference equations developed for other populations. Anthropometry, spirometry, reported physical activity, and two walk tests in a 30-m corridor were evaluated in 134 subjects (73 females, 13-84 years). Mean 6MWD and 6MWw were significantly greater in males than in females (622 ± 80 m, 46,322 ± 10,539 kg.m vs 551 ± 71 m, 36,356 ± 8,289 kg.m, P < 0.05). Four equations significantly overestimated measured 6MWD (range, 32 ± 71 to 137 ± 74 m; P < 0.001), and one significantly underestimated it (-36 ± 86 m; P < 0.001). 6MWD significantly correlated with age (r = -0.39), height (r = 0.44), body mass index (r = -0.24), and reported physical activity (r = 0.25). 6MWw significantly correlated with age (r = -0.21), height (r = 0.66) and reported physical activity (r = 0.25). The reference equation devised for walk distance was 6MWDm = 622.461 - (1.846 x Ageyears) + (61.503 x Gendermales = 1; females = 0); r2 = 0.300. In an additional group of 85 subjects prospectively studied, the difference between measured and the 6MWD predicted with the equation proposed here was not significant (-3 ± 68 m; P = 0.938). The measured 6MWD represented 99.6 ± 11.9% of the predicted value. We conclude that 6MWD and 6MWw variances were adequately explained by demographic and anthropometric attributes. This reference equation is probably most appropriate for evaluating the exercise capacity of Brazilian patients with chronic diseases.
Acidente com material perfurocortante entre profissionais de enfermagem de um hospital universitário
Resumo:
Os riscos ocupacionais a que os profissionais da equipe de enfermagem estão sujeitos no desempenho de suas funções são consideráveis. Assim estabeleceu-se como objetivo deste estudo analisar os acidentes perfurocortantes no período de 2002 a 2006, envolvendo a equipe de enfermagem de um hospital universitário, para compreender o contexto em que ocorrem. A utilização destas informações pode ser ferramenta de prevenção. Estudo descritivo, retrospectivo quantitativo e qualitativo. Na análise quantitativa foi utilizada estatística descritiva e na qualitativa o discurso do sujeito coletivo. Por meio das fichas de notificação do Núcleo de Vigilância Epidemiológica do Hospital, foi possível identificar acidentes do gênero no período pesquisado. Entrevistas foram direcionadas às vítimas de acidentes que tiveram como paciente-fonte portador de Síndrome da Imunodeficiência Adquirida/ Vírus da Imunodeficiência Humana, hepatite B e C. Os achados demonstraram que ainda persiste um grau significativo do desconhecimento ou banalização dos acidentes entre profissionais da saúde.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
OBJETIVO: Investigar alterações da margem palpebral em portadores de ectrópio. MÉTODOS: Foi feito estudo observacional, do qual participaram 53 portadores de ectrópio palpebral e 25 portadores de dermatocálase (grupo controle), estudando-se, a partir de imagens digitais, a posição dos cílios e a presença de inflamações na margem palpebral. Os dados foram submetidos a análise estatística. RESULTADOS: Os portadores de ectrópio apresentaram com maior freqüência diminuição do número de cílios, perda da convexidade, triquíase e distiquíase quando comparados aos indivíduos do grupo controle. CONCLUSÃO: O portador de ectrópio possui alterações da margem palpebral provavelmente decorrentes do processo inflamatório crônico que ocorre na região.
Resumo:
Background the aim of this study was to compare effective and sham intravaginal electrical stimulation (IES) in treating mixed urinary incontinence. Methods. Between January 2001 and February 2002, 40 women were randomly distributed, in a double-blind study, into two groups: group G1 (n = 20), effective IES, and group G2 (n = 20), sham IES, with follow up at one month. Different parameters was studied: 1. clinical questionnaire, 2. body mass index; 3. 60-min pad test; 4. urodynamic study. The protocol of IES consisted of three 20-min sessions per week over a seven-week period. The Dualpex Uro 996 used a frequency of 4 Hz. Results. There was no statistically significant difference in the demographic data of both groups. The number of micturitions per 24 h after treatment was reduced significantly in both groups. Urge incontinence was reduced to 15% in G1 and 31.5% in G2; there was no significant difference between the groups. In the analog wetness and discomfort sensation evaluations were reduced significantly in both groups. The pretreatment urodynamic study showed no statistical difference in urodynamic parameters between the groups. Ten percent of the women presented involuntary detrusor contractions. In the 60-min pad test, there was a significant reduction in both groups. In regards to satisfaction level, after treatment, 80% of G1 patients and 65% of G2 patients were satisfied. There was no statistically significant difference between the groups. Conclusion. Significant improvement was provided by effective and sham electrostimulation, questioning the effectiveness of electrostimulation as a monotherapy.
Resumo:
Purpose: The aim of this study was to compare 2 different methods of assessment of implants at different inclinations (90 degrees and 65 degrees)-with a profilometer and AutoCAD software. Materials and Methods: Impressions (n = 5) of a metal matrix containing 2 implants, 1 at 90 degrees to the surface and 1 at 65 degrees to the surface, were obtained with square impression copings joined together with dental floss splinting covered with autopolymerizing acrylic resin, an open custom tray, and vinyl polysiloxane impression material. Measurement of the angles (in degrees) of the implant analogs were assessed by the same blinded operator with a profilometer and through analysis of digitized images by AutoCAD software. For each implant analog, 3 readings were performed with each method. The results were subjected to a nonparametric Kruskal-Wallis test, with P <= .05 considered significant. Results: For implants perpendicular to the horizontal surface of the specimen (90 degrees), there were no significant differences between the mean measurements obtained with the profilometer (90.04 degrees) and AutoCAD (89.95 degrees; P=.9142). In the analyses of the angled implants at 65 degrees in relation to the horizontal surface of the specimen, significant differences were observed (P=.0472) between the mean readings with the profilometer (65.73 degrees) and AutoCAD (66.25 degrees). Conclusions: The degrees of accuracy of implant angulation recording vary among the techniques available and may vary depending on the angle of the implant. Further investigation is needed to determine the best test conditions and the best measuring technique for determination of the angle of the implant in vitro.
Resumo:
This study evaluated: 1) the effect of different ceramics on light attenuation that could affect microhardness, measured as the Knoop Hardness Number (KHN), of a resin cement immediately and 24 hours after polymerization and 2) the effect of different activation modes (direct light-activation, light activation through ceramics and chemical activation) on the KHN of a resin cement.Resin cement Rely X ARC (3M ESPE) specimens 5.0 mm in diameter and 1.0 nun thick were made in a Teflon mold covered with a polyester film. The cement was directly light activated for 40 seconds with an XL 2500 curing unit (3M ESPE) with 650 mW/cm(2), light activated through ceramic discs of Duceram Plus (DeguDent), Cergogold (DeguDent), IPS Empress (Ivoclar), IPS Empress 2 (Ivoclar), Procera. (NobelBiocare), In Ceram Alumina (Vita) and Cercon (DeguDent), having a 1.2 mm thickness or chemically activated without light application. The resin cement specimens were flattened, and KHN was obtained using an HMV 2 microhardness tester (Shimadzu) with a load of 50 g applied for 15 seconds 100 pin from the irradiated surface immediately and after storage at 37 degrees C for 24 hours. Ten measurements were made for each specimen, with three specimens for each group at each time. The data were submitted to ANOVA and Tukey's test (p=0.05). The KHN of the resin cement was not only affected by the mode of activation, but also by the post-activation testing time. The mean KHN of the resin cement for chemical activation and through all ceramics showed statistically significant lower values compared to direct activation immediately and at 24 hours. The KHN for 24 hours post-activation was always superior to the immediate post-activation test except with direct activation. The most opaque ceramics resulted in the lowest KHN values.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The objective of this study was to determine the level of resistance of Haemonchus contortus and Trichostrongylus colubriformis in sheep to levamisole albendazole ivermectin moxidectin closantel and trichlorfon The parasites were isolated from sheep naturally infected by gastrointestinal nematodes and were then kept in monospecifically infected lambs for production of infective larvae (L3) of both species Forty-two lambs at three months of age were simultaneously artificially infected with 4000 L3 of H contortus and 4000 L3 of T colubriformis The animals were allocated Into seven groups with six animals each that received one of the following treatments Group 1-control no treatment Group 2-moxidectin (0 2 mg/kg body weight (BW)) Group 3-closantel (10 mg/kg BW) Group 4-trichlorfon (100 mg/kg BW) Group 5-levamisole phosphate (4 7 mg/kg BW) Group 6-albendazole (5 0 mg/kg BW) and Group 7-ivermectin (0 2 mg/kg BW) Nematode fecal egg counts (FEC) were carried out on the day of treatment and again at 3 7 10 and 14 days post-treatment on the same occasions composite fecal cultures were prepared for each group for production of L3 which were identified into genus The animals were sacrificed for worm counts at 14 days after treatment The efficacy of each treatment was calculated from the arithmetic mean of the FEC or worm burden of the treated group compared with the values of the control group Only trichlorfon and moxidectin treatments resulted in a significant reduction of H contortus recorded at necropsy (73% and 45% respectively) Moxidectin reduced T colubriformis worm burdens by 82% and albendazole by 19% All other anthelmintics resulted in no significant reduction in the numbers of worms found at necropsy In conclusion the Isolates of H contortus and T colubriformis showed multiple resistance to all groups of anthelmintics tested This is the first report based on the controlled efficacy test to show resistance of T colubriformis to macrocyclic lactones in Brazil (C) 2010 Elsevier B.V. All rights reserved
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
We consider the management branch model where the random resources of the subsystem are given by the exponential distributions. The determinate equivalent is a block structure problem of quadratic programming. It is solved effectively by means of the decomposition method, which is based on iterative aggregation. The aggregation problem of the upper level is resolved analytically. This overcomes all difficulties concerning the large dimension of the main problem.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
We present a search for electroweak production of single top quarks in the s-channel and t-channel using neural networks for signal-background separation. We have analyzed 230 pb(-1) of data collected with the DO detector at the Fermilab Tevatron Collider at a center-of-mass energy of 1.96 TeV and find no evidence for a single top quark signal. The resulting 95% confidence level upper limits on the single top quark production cross sections are 6.4 pb in the s-channel and 5.0 ph in the t-channel. (c) 2005 Elsevier B.V. All rights reserved.