This work describes a methodology for power factor control and correction of the unbalanced currents in four-wire electric circuits. The methodology is based on the insertion of two compensation networks, one wye-grounded neutral and other in delta, in parallel to the load. The mathematical development has been proposed in previous work [3]. In this paper, however, the determination of the compensation susceptances is based on the instantaneous values of load currents. The results are obtained using the MatLab-Simulink enviroment
Resumo:
An analysis of the performance of six major methods of loss allocation for generators and demands was conducted, based on pro-rata (two), on incremental factors (two), on proportional sharing (PS) (one), and on electric circuit theory (one). Using relatively simple examples which can easily be checked, the advantages and disadvantages of each were ascertained and the results confirmed using a larger sample system (IEEE-118). The discussion considers the location and size of generators and demands, as well as the merits of the location of these agents for each configuration based on an analysis of the effect of various network modifications. Furthermore, an application in the South-Southeastern Brazilian Systems is performed. Conclusions and recommendations are presented. (C) 2004 Elsevier B.V. All rights reserved.
Resumo:
The data of four networks that can be used in carrying out comparative studies with methods for transmission network expansion planning are given. These networks are of various types and different levels of complexity. The main mathematical formulations used in transmission expansion studies-transportation models, hybrid models, DC power flow models, and disjunctive models are also summarised and compared. The main algorithm families are reviewed-both analytical, combinatorial and heuristic approaches. Optimal solutions are not yet known for some of the four networks when more accurate models (e.g. The DC model) are used to represent the power flow equations-the state of the art with regard to this is also summarised. This should serve as a challenge to authors searching for new, more efficient methods.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
This work presents a case study on technology assessment for power quality improvement devices. A system compatibility test protocol for power quality mitigation devices was developed in order to evaluate the functionality of three-phase voltage restoration devices. In order to validate this test protocol, the micro-DVR, a reduced power development platform for DVR (dynamic voltage restorer) devices, was tested and the results are discussed based on voltage disturbances standards. (C) 2011 Elsevier B.V. All rights reserved.
Resumo:
An adaptive scheme is shown by the authors of the above paper (ibid. vol. 71, no. 2, pp. 275-276, Feb. 1983) for continuous time model reference adaptive systems (MRAS), where relays replace the usual multipliers in the existing MRAS. The commenter shows an error in the analysis of the hyperstability of the scheme, such that the validity of this configuration becomes an open question.
Resumo:
Parasitic diseases in humans, transmitted by insects, affect about 500 million people living mainly in countries of low economic power. The control of these diseases is difficult to carry out, mianly due to social and political problems, enhanced by the capacity of these organisms to develop resistance to insecticides used to for their destruction. Some recent advances in the area of insect immunology have open the possibility for abetter epidemiological control of these diseases. The immune system of these insects, as well as that of other organisms, have the ability to recognize the infecting parasites and liberate a series of reactions which stop the infection. These reactions involve the circulating cells (hemocytes) against the parasite. These cells have the ability of phagocytize and liberate the production of various humoral factors, neutralizing the infection. Some promising results, obtained by the study of the immune system of malaria-transmitting insects, the sleeping disease, and dengue, are an example of this new sanitary strategy.
Resumo:
In this work, the linear and nonlinear feedback control techniques for chaotic systems were been considered. The optimal nonlinear control design problem has been resolved by using Dynamic Programming that reduced this problem to a solution of the Hamilton-Jacobi-Bellman equation. In present work the linear feedback control problem has been reformulated under optimal control theory viewpoint. The formulated Theorem expresses explicitly the form of minimized functional and gives the sufficient conditions that allow using the linear feedback control for nonlinear system. The numerical simulations for the Rössler system and the Duffing oscillator are provided to show the effectiveness of this method. Copyright © 2005 by ASME.
Resumo:
It may be difficult for small and medium cities to obtain information about the fluoride content of public water, because of the lack of equipments and technicians. This study aimed to analyze the fluoride levels of the water supplied by the public treatment stations of 40 cities situated in the northwest region of São Paulo State, during a period of 6 months, to verify if fluoridation occurs in a continuous manner and if the fluoride levels are within the recommended. Maps of the water distribution system were obtained from the water treatment companies and utilized to randomize the addresses of the collection sites, so that they included all regions with treated water sources. One water sample by month was collected and analyzed in duplicate using an ion-specific-electrode. Samples with 0.6 to 0.8 mgF/L were considered acceptable. In the 38 cities that regularly provided the samples in the 6 months of the study, water from 144 collection sites was collected and a total of 864 samples were analyzed, of which 61.81 percent were classified as unacceptable. It was observed that 33 cities performed fluoridation but in 78.79 percent of these cities there were variations in the fluoride level among the sites and in the same site during the period of study. One can conclude that most of these cities do not control the fluoride levels in the public water, since fluoridation occurs in a discontinuous manner and in most of the situations not within the recommended concentrations.
Resumo:
In this article, the authors measure throughput of sonic diamond microtubes and micronozzles that can work as passive gas flow controllers and flow meters under choking conditions. The behavior of the outlet pressure through the microdevices using an experimental setup with constant volume and constant temperature was determined in order to obtain the critical throughput, the critical mass flow rate, and the discharge coefficients of the diamond sonic microdevices. © 2007 American Vacuum Society.
Resumo:
The need for a rational use of water and supply of food for a growing world population have led to the development of research in the area of irrigation systems. Thus, some irrigation systems which join efficiency with low cost of material have been developed. Although some technical characteristics are provided by the manufacturers, tests are required to verify functioning of the system and uniformity of water distribution. Continuous research on uniformity, characteristics of the materials and design of water distribution systems is essential for system improvement. Therefore, the objective of this work was to evaluate the CV (manufacturer's coefficient of variation) of Amanco microsprinkler (1.0 mm light green nipple) using bench testing in the laboratory of Irrigation at UNESP - FCA campus of Botucatu-SP. Twenty-five microsprinklers in a sequential design were used in the tests. Three flow systems were tested as follows: a Coil system based on serial connected pipes; a Lateral system, the most common system in which secondary lines are fed by a main line; and a Mesh system used in the urban water supply. The results showed that 4.17% CVf met the production standards and the Lateral and Mesh systems were similar regarding outflow using bench testing. The Mesh system presented the highest mean value of outflow and the lowest range of variation.
Resumo:
The aim of this paper is to study the cropping system as complex one, applying methods from theory of dynamic systems and from the control theory to the mathematical modeling of the biological pest control. The complex system can be described by different mathematical models. Based on three models of the pest control, the various scenarios have been simulated in order to obtain the pest control strategy only through natural enemies' introduction. © 2008 World Scientific Publishing Company.
Resumo:
A bilevel programming approach for the optimal contract pricing of distributed generation (DG) in distribution networks is presented. The outer optimization problem corresponds to the owner of the DG who must decide the contract price that would maximize his profits. The inner optimization problem corresponds to the distribution company (DisCo), which procures the minimization of the payments incurred in attending the expected demand while satisfying network constraints. The meet the expected demand the DisCo can purchase energy either form the transmission network through the substations or form the DG units within its network. The inner optimization problem is substituted by its Karush- Kuhn-Tucker optimality conditions, turning the bilevel programming problem into an equivalent single-level nonlinear programming problem which is solved using commercially available software. © 2010 IEEE.
Resumo:
Smart micro-grids offer a new challenging domain for power theories and metering techniques, because they include a variety of intermittent power sources which positively impact on power flow and distribution losses, but may cause voltage asymmetry and frequency variation. Due to the limited power capability of smart micro-grids, the voltage distortion can also get worse (in case of supplying non-linear loads), affecting measurement accuracy and possibly causing tripping of protections. In such a context, a reconsideration of power theories is required, since they form the basis for supply and load characterization. A revision of revenue metering techniques is also needed, to ensure a correct penalization of the loads for their responsibility in generating reactive power, voltage unbalance and distortion. This paper shows that the Conservative Power Theory (CPT) provides a suitable background to cope with smart grids characterization and metering needs. Experimental results validate the proposed approach. © 2010 IEEE.
Resumo:
In this paper we propose an accurate method for fault location in underground distribution systems by means of an Optimum-Path Forest (OPF) classifier. We applied the Time Domains Reflectometry method for signal acquisition, which was further analyzed by OPF and several other well known pattern recognition techniques. The results indicated that OPF and Support Vector Machines outperformed Artificial Neural Networks classifier. However, OPF has been much more efficient than all classifiers for training, and the second one faster for classification. © 2011 IEEE.