290 resultados para Concentric cylinder rheometers


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: Exercise with flexible poles provides fast eccentric and concentric muscle contractions. Although the literature reports significant muscle chain activity during this exercise, it is not clear if a single bout of exercise induces cardiac changes. In this study we assessed the acute effects of flexible pole exercise on cardiac autonomic regulation.Methods: The study was performed on 22 women between 18 and 26 years old. We assessed heart rate variability (HRV) in the time (SDNN, RMSSD and pNN50) and frequency (HF, LF and LF/HF ratio) domains and geometric indices of HRV (RRTri, TINN, SD1, SD2 and SD1/SD2 ratio). The subjects remained at rest for 10 min and then performed the exercises with the flexible poles. Immediately after the exercise protocol, the volunteers remained seated at rest for 60 min and HRV was analyzed.Results: We observed no significant changes in time domain (SDNN: p=0.72; RMSSD: p=0.94 and pNN50: p=0.92) or frequency domain indices (LF [nu]: p=0.98; LF [ms(2)]: p=0.72; HF [nu]: p=0.98; HF [ms(2)]: p=0.82 and LF/HF ratio: p=0.7) or in geometric indices (RRTri: p=0.54; TINN: p=0.77; SD1 p=0.94; SD2: p=0.67 and SD/SD2: p=0.42) before and after a single bout of flexible pole exercise.Conclusion: A single bout of flexible pole exercise did not induce significant changes in cardiac autonomic regulation in healthy women. (C) 2014 Sociedade Portuguesa de Cardiologia. Published by Elsevier Espana, S.L.U. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to investigate the effects of Er:YAG and Nd:YAG lasers on the shear bond strength of composite resin to dentin. The coronal portion of 56 human molars was divided into three parts, and the dentin thickness was standardized at 2 mm. A 3-mm hole was marked in the center of each tooth with sealing tape paper. The specimens (n = 14) were then divided into four groups: (1) acid etching + Single Bond (SB) (control), (2) acid etching + SB + Nd:YAG laser irradiation (before adhesive curing), (3) thermal etching with the Er:YAG laser + SB, and (4) thermal etching with the Er:YAG laser + SB + Nd:YAG laser irradiation (before adhesive curing). A composite resin cylinder was built into the delimited area for conducting the shear bond strength test on the universal testing machine. The means ± standard deviations were: group 1, 17.05 ± 4.15 MPa; group 2, 16.90 ± 3.36 MPa; group 3, 12.12 ± 3.85 MPa; and group 4, 12.92 ± 2.73 MPa. Groups 1 and 2 presented significantly higher values than groups 3 and 4. It was concluded that conventional etching with 37% phosphoric acid yielded significantly higher bond strength values compared to thermal etching with the Er:YAG laser. The Nd:YAG laser did not significantly influence the bond strength.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Considering the importance of muscle strength to functional capacity in the elderly, the study investigated the effects of age on isokinetic performance and torque production as a function of muscle length. Eleven younger (24.2±2.9years) and seventeen older men (62.7±2.5years) were subjected to concentric and eccentric isokinetic knee extension/flexion at 60°.s-1 and 120°.s-1 through a functional range of motion. The older group presented lower peak torque (Nm) than the young group for both isokinetic contraction types (age effect, p<0.001). Peak torque deficits in the older group were near 30% and 29% for concentric and eccentric contraction, respectively. Concentric peak torque was lower at 120.s-1 than at 60.s-1 for both groups (angular velocity effect, p<0.001). Eccentric knee extension torque was the only exercise tested that showed an interaction effect between age and muscle length (p<0.001), which suggested different torque responses to the muscle length between groups. Compared with the young group, the eccentric knee extension torque was 22% to 56% lower in the older group, with the deficits being lower in the shortened muscle length (22-27%) and higher (33-56%) in stretched muscle length. In older men, the production of eccentric knee strength seems to be muscle length-dependent. At more stretched positions, older subjects lose the capacity to generate eccentric knee extension torque. More studies are needed to assess the mechanisms involved in eccentric strength preservation with aging and its relationship with muscle length.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Mecânica - FEG

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The disadvantages generated by the acid etching of the dentin, such as an increase in its permeability, in the surface moisture and in the potential to denature the external dentinal collagen, the formation of a fragility zone and the citotoxicity of the adhesive monomers; which are all aggravated by the depth of the dentin, have stimulated new and different treatment philosophies of the dentin. The purpose of the present study, therefore, was to investigate the effects of three dentin treatments: laser irradiation, acid etching and hypermineralization, in the shear bond strength of the SMP Plus bonding system. Sixty bovine incisors were extracted and randomly selected immediatly alter the animal's death. They were kept frozen (-18°C) for no longer than 14 days. After buccal dentinal surface had been exposed, X-Rays were taken to control the dentin thickness. The specimens were separated into two groups: (1) Control, kept in distilled water at 4ºC; (2) Mineralized, kept in hypermineralized solution at 4°C for 14 days. Each group was divided into three sub-groups according to the type of dentin treatment used: group F - followed the manufacturer instructions (acid-etching + primer + bond), group AL (acid-etching + primer + bond + laser) and group LA (laser + (laser + acid-etching + primer + bond). A composite resin standard cylinder (Z100-3M) was bond to the dentinal surface and the shear bond strength performed on a Universal lnstron machine 4301, with 500 Kg load and at 0,5mm/min. speed. The analysis of variance (ANOVA) determined that the treatments influenced the shear bond strength values (p<0,05) with the following average shearing load at failure: AL (9,96 MPa), F (7,28MPa) e LA (4,87 MPa). The interaction between the two factors analyzed Group (control and mineralized) and treatment (F, AL, LA) also influenced the shear bond strength (p<0,05). The highest values were obtained...

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The analysis of the feasibility and economics of amorphous core power transformers for induction heating applications in the field 10-50 kHz is developped. The results obtained on a 25 kHz-150 kVA concentric winding trial unit are presented. © 1990.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The design of implant structure is still a questioning to the professionals, while their variations can to influence of stress distribution favorably to bone. Therefore, the aim of study was to review addressing the topic of osseointegrated implants design establishing answers for the patient oral rehabilitation, according variations existing on the market. It was conducted a detailed search strategy by the PubMed/ Medline and Bireme, it was used as descriptors: “dental implants cylinder”; “dental implants thread”; “dental implants geometry”, until May 2014. From 798 articles, after review were selected 18 articles and 1 specific area book. The results were divided to compare design of implant and threads for further discussion and conclusions. Thus, conclude that the threads implants are best used because of its advantages with respect to the stress distribution and stability primary. The variations of the differents types of threads, have influence for stress distribution.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Twelve athletes (13,9±1,1 years, 169,0±6,0 cm and 59,5±13,5 kg ofbody weight) were under went to anthropometric and body compositionassessments, and maximum concentric strength of lower limbs. The jumptest in the water was done by ‘boost’ and scaled to jump height. The resultsof strength (Leg Press 45: 157,1±43,3 kg; Leg Extension: 72,1±12,9 kg),anthropometry (circumferences of arm: 26,0±3,3 cm; thigh: 50,5±7,7 cm;shoulder: 96,0±8,0 cm, and diameter of elbow: 4,7±0,5 cm; wrist: 3,2±0,3cm; knee: 7,9±0,6 cm; bi-acromial: 37,5±3,8 cm; and bi-iliac: 25,4±4,3cm), BMI (20,7±4,0 kg/m²), and body composition (fat: 8,5±4,3%) were notrelated to the values of vertical jump performance (47,80 ? 4,35 cm), as didshowed for body height (0,595). Thus, athletes height was one able to influencethe jump performance by modifying it self, perhaps by maturity.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study focuses on analysing the effects of nonlinear torsional stiffness on the dynam-ics of a slender elastic beam under torsional oscillations, which can be subject to helical buckling.The helical buckling of an elastic beam confined in a cylinder is relevant to many applications. Someexamples include oil drilling, medical cateters and even the conformation and functioning of DNAmolecules. A recent study showed that the formation of the helical configuration is a result of onlythe torsional load, confirming that there is a different path to helical buckling which is not related tothe sinusoidal buckling, stressing the importance of the geometrical behaviour of the beam. A lowdimensional model of an elastic beam under torsional oscillations is used to analyse its dynamical be-haviour with different stiffness characteristics, which are present before and after the helical buckling.Hardening and softening characteristics are present, as the effects of torsion and bending are coupled.With the use of numerical algorithms applied to nonlinear dynamics, such as bifurcation diagramsand basins of attraction, it is shown that the nonlinear stiffness can shift the bifurcations and inducechanges in the stability of the desirable and undesirable solutions. Therefore, the proper modellingof these stiffness nonlinearities seems to be important for a better understanding of the dynamicalbehaviour of such beams.