324 resultados para Carga estática equivalente
Resumo:
Pós-graduação em Engenharia Elétrica - FEIS
Resumo:
The objective of this work was to determine the load support capacity (LSC) of an Oxisol and, through compressibility models, relate it to wheel-soil interactions under management systems with one and three sugarcane crop cycles, with mechanized harvest. LSC evaluations were carried out on undisturbed soil samples, collected at planting row and bed, in four layers: 0.00-0.10, 0.10-0.20, 0.20-0.30, and 0.300.40 m. The contact area between wheels and soil was determined in order to estimate the contact pressure by agricultural machinery on the soil. Pre-consolidation pressures were used to determine LSC. The system with three cycles showed higher LSC than the system with only one cycle. The load support capacity of the soil evaluated in the range of friability is greater than the contact pressures applied to the soil by the wheels of the studied agricultural machines.
Resumo:
Pós-graduação em Engenharia Mecânica - FEG
Resumo:
Pós-graduação em Biotecnologia Animal - FMVZ
Resumo:
Pós-graduação em Enfermagem (mestrado profissional) - FMB
Resumo:
INTRODUÇÃO: Um dos benefícios promovidos pelo exercício físico parece ser a melhora da modulação do sistema nervoso autônomo sobre o coração. No entanto, o papel da atividade física como um fator determinante da variabilidade da frequência cardíaca (VFC) não está bem estabelecido. Desta forma, o objetivo do estudo foi verificar se há correlação entre a frequência cardíaca de repouso e a carga máxima atingida no teste de esforço físico com os índices de VFC em homens idosos. MÉTODOS: Foram estudados 18 homens idosos com idades entre 60 e 70 anos. Foram feitas as seguintes avaliações: a) teste de esforço máximo em cicloergômetro utilizando-se o protocolo de Balke para avaliação da capacidade aeróbia; b) registro da frequência cardíaca (FC) e dos intervalos R-R durante 15 minutos na condição de repouso em decúbito dorsal. Após a coleta, os dados foram analisados no domínio do tempo, calculando-se o índice RMSSD, e no domínio da frequência, calculando-se os índices de baixa frequência (BF), alta frequência (AF) e razão BF/AF. Para verificar se existe associação entre a carga máxima atingida no teste de esforço e os índices de VFC foi aplicado o teste de correlação de Pearson (p < 0,05). RESULTADOS: Características demográficas, antropométricas, fisiológicas e carga máxima atingida no teste ergométrico: idade = 63 ± 3,0 anos; IMC = 24 ± 2kg/m²; FC = 63 ± 9bpm; PAS = 123 ± 19mmHg; PAD = 83 ± 8mmHg; carga máxima = 152 ± 29 watts. Não houve correlação entre os índices de VFC com os valores de FC de repouso e carga máxima atingida no teste ergométrico (p > 0,05). CONCLUSÃO: Os índices de variabilidade da frequência cardíaca temporal e espectrais estudados não são indicadores do nível de capacidade aeróbia de homens idosos avaliados em cicloergômetro.
Resumo:
Composting is considered a process that enables adding value to organic solid waste turning them into organic fertilizer. In this process, factors such as mishandling the windrow, failed to control the temperature, aeration and moisture content will result in the quality of waste decomposition, and thus affect the quality of the final compound. Decentralized systems such as home composting, composting in restaurants, food courts and schools are one of the solutions for valuing these waste in a non expensive way and with greater quality. For this purpose, the project aims to analyze the conditions for composting of solid waste of the University Restaurant of Rio Claro- SP, through two different composting systems: manual revolving windrow and static pile. It was found that in University Restaurant (RU) on average 33% by weight of the total waste generated in the property are capable of composting. In this sense, in order to investigate the preliminary process operation parameters were mounted one manual windrow composed of 100% of the UR waste and a static pile composed of 60% of the UR waste and 40% of pruning and grass residues (PG). This study analyzed the manual revolving windrow and static pile systems for the parameters: moisture content, pH, C / N ratio and temperature. The study of the proportions of the PG and UR waste pointed to the need for pruning and grass residues addition for composting, considering that the manual revolving windrow composed by 100% of the UR waste had no satisfactory performance due to low temperatures measured during 60 days analysis. The best ratio for manual revolving windrow method analyzed in this study was 60% of the UR waste and 40% of PG waste, in dry weight. From this proportion a static pile was assembled, composed of 60% of UR waste e 40% of PG waste from the maintenance activities of the green area of the university. The biological activity in the static pile reached the maximum temperature of ...
Resumo:
Pós-graduação em Ciências da Motricidade - IBRC
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The response of bone metabolism is directly related to hormonal factors and mechanical stimuli that the bone is exposed. The ultrasonic energy on bone healing have been shown to be crucial for the stimulation and improvement in quality of newly formed tissue. The aim of this study was to analyze the action of low intensity ultrasound on bone healing of tibial osteotomy in rats subjected to tail suspension, through histological analysis and histomorphometry. Eighteen Rattus norvegicus albinos, Wistar, adults were divided into three groups, arranged as follows: G1 (n = 6), who remained free for a period of 15 days, G2 (n = 5), suspended by the tail for a period of 15 days and G3 (n = 7), suspended by the tail for a period of 36 days. In all three groups, both tibias were subjected to mono-cortical bone injury 4X2 mm in the medial region of the diaphysis, and the left limb was used as control and the right limb undergoing treatment with ultrasound (U.S.). The right tibia was treated with pulsed ultrasound at a frequency of 1.5 MHz, duty cycle 1:4, 30mW/cm2, for 12 sessions of 20 minutes each. Samples of tibia were subjected to histological analysis, blindly, with light microscopy and histomorphometric analysis by specific software Image-Pro 6.1. The average percentage of new bone formation were subjected to analysis of variance in subdivided parcels and multiple comparison test "Student-Newman-Keuls (SNK), with a significance level of 5%. The average values and standard deviations of the percentage of newly formed bone for the groups showed the least amount of bone repair G1t (13.62% ± 4.88%) - G1c (8.68% ± 4.16%) compared G2t groups (27.17% ± 11.36%) - G2c (10.10% ± 7.90%) and G3t (23.19% ± 5.61%) - G3c (15.74% ± 7 08%). However, the mean values and standard deviations of the percentage of newly formed bone repair in the tibia treated G2t and G3t were significantly higher when compared to the repair of tibia in the control group (G2c and G3c). Consequently, we conclude that ultrasound has helped to accelerate bone repair in both the presence and absence of cargo.
Resumo:
Low-intensity laser has been used as a physical agent in various fields of medical sciences such as bone and tissue repair. Meanwhile little is known about its effects in adverse conditions such as abolition of load and osteopenic. With the assumption that the laser Ga-Al-As accelerates the process of bone consolidation, goal of this study was to evaluate bone mineral density (BMD) in incomplete transverse osteotomies of tibia in adult rats, treated with low power laser therapy in three different groups: G1 (n = 10), reference 15 days; G2 (n=10), suspended by the tail and, accordingly, treated with laser for 12 days; G3 (n = 10), suspended by the tail by 36 days and that after 21 days, there was laser treatment for 12 days. The right tibia treated with laser and left served as control. The laser was used to Ga-Al-As, DMC - Flash Lase® III, with wavelength 830nm, 100 mW, 4J, 140 J / cm ², 40s of application in 12 sessions. It was used densitometer-Lunar DPX®, with computer program for "small animals", and the analysis of BMD was made in the bone throughout the region and the osteotomy. The results showed no efficacy of laser therapy in the process of bone repair, both in animals of group 1, as in group 2 and 3. It follows that either the low-power laser was not an effective performance or the effects of laser therapy is not only manifested at the site of irradiation as well as the systemic level.