331 resultados para Capacitores e filtros para baixa tensão
Resumo:
The proposed of scanning of an electrical industrial substation HV is associated with a segment of the Electrotechnical area and aims the study and preliminary application of digital technologies in the protection, control, measurement and automation maneuvers aimed at a Industrial Electrical System typical High Voltage. Well intended to supervision, protection and control of major electrical and thermal quantities involved in a substation, such as voltage levels, current, temperature, power factor, loads of transformers and circuit feeders, status of interlocking devices, switching equipment maneuvers, etc
Resumo:
The quality assurance control program (QACP) in clinical radiology is very important to acquire, image quality, patient dose reduction and cost for the institution. The verification of the real tension on the x ray tube, it is one of many parameters that may be determined on a QACP. This act on image quality as absorbed dose in patient. Once proved the importance of this fact, this study come up with the determination of tension to any X ray tube used on medical routine, on quick, safe and low cost manner. To reach the aim of this study, the methodology consisted on measuring expose rates (ER) using different thicknesses of copper (Cu) plates like filters and relating these results with Half Layer Value (HLV). Afterwards, the HLV was associated to real tension that was acquired with kilo voltage of peak (kVp) measurers used on clinical routine. So walking in this path, when performed the ER, on any X ray tube, it’s possible acquire the HLV and consequently the real kVp, considering measures obtained before, on the methodology of kVp estimative development
Resumo:
This work discusses about the effects and methods of control and elimination of the currents transients generated by switching capacitor banks, this currents are called inrush currents. Capacitor banks are widely used to compensate a low power factor generated by the widespread use of inductive loads. Currently many of these banks are automatic and therefore the capacitive cells are connected and disconnected according to the inductive loads on the network. However when connecting a capacitor bank to a bus can generate currents transients generated by electromagnetic transients. Aspects of the network, for example, the existence of a bank already connected to the bus, can influence the intensity of this phenomenon. This paper discusses some characteristics of the capacitors and the network to justify and explain the appearance of these transients and discusses its effects on the network and to other equipment. It is concluded that the main cause of this phenomenon is the voltage difference between the capacitor to be connected to the network and the bus, the results of the study were the bases to discuss the traditional methods to mitigate these currents and therefore its negative effects. Although in this paper is yet developed a method of electronic switching that can greatly reduce these transients
Resumo:
The technological advancement in order to improve the methods of obtaining energy sources such as oil and natural gas is mainly motivated by the recent discovery of oil reserves. So, increasingly , there is a need for a thorough knowledge of the materials used in the manufacture of pipelines for transportation and exploration of oil and natural gas. The steels which follow the API standard (American Petroleum Institute), also known as high strenght low alloy (hsla), are used in the manufacture of these pipes, as they have, with their welded joints, mechanical properties to withstand the working conditions to which these ducts will be submitted . The objective of this study is to evaluate the fatigue behavior in microalloyed steel grade API 5L X80 welded by process HF / ERW . For this, axial fatigue tests to obtain S-N curve (stress vs. number of cycles ) were conducted. To complement the study, it was performed metallographic , fractographic , Vickers hardness tests and tensile tests to characterize the mechanical properties of the steel and check whether the values satisfy the specifications of the API 5L standard . From the fatigue tests , it was concluded that the surface finish influences directly on the fatigue life of the material
Resumo:
Along with the advance of technology, in terms of the expansion of medical exams that uses the ionizing radiation for diagnosis, there is also the concern about quality control for maintaining quality in radiographic imaging and for delivering low dose to the patient. Based on the Federal Order 453 of the Secretariat of Health Surveillance, which takes account of the practical and justification of individual medical exposures, the optimization of radiological protection, limitation of individual dose, and the prevention of accidents, were done through this paper radiodiagnostic tests on medical equipment in order to accept it or not, according to SVS-453. Along with the help and support of P&R Consulting and Medical Physics Marilia, SP, were made Quality Control and Radiometric Control in equipment from various cities across the state of São Paulo. The equipment discussed in this work is classified as conventional X-ray. According to the Federal Order SVS-453, the quality control in the program of quality assurance should include the following minimum set of constancy tests, with following minimum frequency: biennial tests for representative values of dose given to the patients of radiography and CT performed in the service; annual tests for accuracy of the indicator tube voltage (kVp), accuracy of exposure time, half-value layer, aligning the central axis of the beam of x-ray tube, performance (mGy / mA.min.m²), linearity of the rate of kerma on air with the mAs, reproducibility of the kerma on air rates, reproducibility of the automatic exposure, focal spot size, integrity of accessories and clothing for individual protection; semiannually for collimation system accuracy; weekly for temperature processing system and sensitometry processing system. For the room Radiometric Survey it was done a sketch...(Complete abstract click electronic access below)
Resumo:
The use of electricity for obtaining light has been quite an issue currently discussed, either through new technologies that are emerging, the quest for greater efficiency, reduced waste and rational use. This work comprises a lighting design applied to a metallurgical based Brazilian Standard 5413 which mentions levels of luminance for interior and, in the case of this work, for a sandblasting booth. Ways to improve the workplace and luminosity presented before the project and also after its implementation are discussed. Technologies are chosen guided by technical calculations according to the illuminance values they want to reach for the environment studied. All pertinent design features are critically analyzed and discussed, and at the end proposals are presented, relating to each other in a comparative framework, so the best solution is applied in a practical way in the enclosure. Results are also presented concerning the maintenance of a bank of capacitors to correct the power factor for the metals studied company
Resumo:
The purpose of this paper is to examine the paratexts, mainly prefaces and notes, written by translators on writings of foreigners' travels in Brazil, with the purpose of evidencing which perspective guided their translations, if the perspective of the foreign author is adopted or if it is that of the domestic reader. The works examined were published by the Brazilian publishing house Companhia Editora Nacional in the Brasiliana Colllection. Most of the translators adopted a welcoming discourse to the author in their prefaces, but their prefaces, translations and notes reveal a certain tension between what they stated and what was effectively done, with moments of rupture in which the author's meanings are questioned and even denied. According to my analysis, this happens because the several forces acting on the translation, the author, the translator and the text to be translated, the languages involved, the reader are not working linearly, but in constant tension. As a result, different perspectives are adopted in different translations, but in the same translation there are moments in which the foreign pole is privileged and moments in which the domestic pole emerges.
Resumo:
Due to concerns about rational use of energy, several alternative technologies of power generation appeared, including the conversion of solar energy into electrical energy by photovoltaic panels. In low-income households, the refrigerator represents considerable impact on the electric bill, since it requires constant power given its use in food preservation. It is possible to reduce this share, with the use of an alternative energy source. This work presents a timed switching electronic system, which allows commercial equipment that is not affected by short interruptions in the power supply to use a photovoltaic panel as a source of alternative energy, which usually do not provide energy continuously. Switching is made automatically in case of low incidence of sunlight, and without any form of energy storage. Between each switching, there is a dead time without power supply, therefore preventing the use of synchronizers circuits between the photovoltaic panel and the public power grid. A circuit containing a 80C31 microcontroller is used to control the system’s switching. The photovoltaic panel’s voltage inverter is in H bridge configuration, and is also controlled by the microcontroller through Pulse Width Modulation, which makes use of preprogrammed tables to generate the control signals of the power transistors. Through the use of software simulations, the proposed system was tested, which is capable of supplying intermittent single-phase loads. The simulations indicates that the project developed in this paper can be assembled into a prototype and be tested under real operating conditions, as long as the scaling of components, the characteristics of the photovoltaic panel to be used, and the project involved load are taken into account
Resumo:
Pós-graduação em Ciências Sociais - FFC
Resumo:
Pós-graduação em Medicina Veterinária - FMVZ
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Engenharia Elétrica - FEIS
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Engenharia Elétrica - FEIS