313 resultados para sobrecarga oclusal


Relevância:

10.00% 10.00%

Publicador:

Resumo:

In industrial plants, there is a department responsible for planning the use of productive resources to find the best possible way to set out plans in strategic, tactical and operational levels. This department is known as PCP or PPCP, which means Planning and Production Control and Planning, Programming and Production Control, respectively. This work presents the use of some of the tools from this department, in particular the Aggregate Production Planning, to propose a new layout of electronic nutrunners for an auto parts industry output line. Through some process indicators analyzes, was identified some productivity losses. The higher loss rate occurred by the electronic nutrunners breaking, and so this work was focused in these devices. Some premises were adopted for the use of electronic nut runners, setting an ideal cycle time for the operation of the production line and making calculations to define the minimum amount of electronic nutrunners to find the production demand without damaging the equipment. With this work we observed that a relevant factor for the constant breaks of electronic nutrunners is because these are working with overload, in other words, the amount of installed equipment is not enough to supply the demand without failures

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Odontologia Restauradora - ICT

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Saúde Coletiva - FMB

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: Aortic insufficiency (AoI), a volume overload, is characterized by the diastolic reflux of blood from the regurgitating aorta to the left ventricle. This effect results from malfunctioning aortic cusps. The main cause of AoI in developing countries is rheumatic fever, including Brazil, and valvar degeneration in developed countries. There is a strong association between cardiovascular diseases and depression. Selective serotonin reuptake inhibitors (SSRI) are one of the most prescribed antidepressants in the world. Previous studies of our laboratory showed that the utilization of a SSRI, paroxetine, improved cardiac function in rats with sub-chronic AoI and reduced the daily ingestion of hypertonic sodium (NaCl 0,3M). Cardiovascular diseases can determine behavior changes like increase of anxiety, and it is yet unknown if AoI would determine anxiety or anhedonia, incapacity of obtaining pleasure through physical or sensorial experiences. A possible target for SSRI action could be a change in the expression of enzyme isoforms that collaborate in the contractile function of the heart muscle, like the heavy chains of myosine, the sarcoplasmatic reticulum Ca2+/ATPase (SERCA) and its regulator protein, phospholamban (PLB). Objectives: Evaluation of behavior parameters for anxiety and anhedonia state and genic expression of a-myosine, b-myosine, SERCA2a and PLB in the heart tissue of rats with subchronic AoI that received treatment with an SSRI (paroxetine) for 4 weeks. Methods: Surgery to induce AoI was performed on male Wistar rats, anxiety was evaluated by the elevated plus-maze (EPM) and state of anhedonia was tested by ingestion of 2% sucrose solution. After euthanasia the heart tissue was collected and total RNA was extracted to be analyzed by the RT-qPCR method. Results: Heart fractional shortening was preserved in rats with AoI that were treated compared to rats with AoI that were not treated. There was no statistically ...

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The pattern of caries lesions has been modified over decades. If the presence or absence of a caries lesion is based upon only a visual examination, its diagnosis might become underestimated since dentinal lesions underneath non cavitated or minimally demineralized enamel is highly frequent in dental clinics. The aim of this paper is to report a clinical case of a child with an upper molar with questionable occlusal aspect, presenting asymptomatic pulpal hyperplasia on the distolingual pit. Periapical radiographic examination was essential for diagnosing hidden caries and elaborating the treatment plan. As part of the approach, removal of the decayed tissue and pulpotomy with calcium hydroxide were performed. The association of an accurate visual examination to an adequate oral radiographyis is extremely important in cases which the presence of hidden caries is doubtful. As a result, an early diagnosis and the reduction of more invasive interventions related to the oral health care of pediatric patients can be achieved as well.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The study aimed to assess the degree of dental crowding correction on the lower anterior region of patients treated with T4k functional appliance using Little’s irregularity index. Twenty caucasian patients of both gender (10 female and 10 male) were selected. They featured malocclusion Class I and II in mixed dentition, with chronological age between 5.7 and 11 years. The treatment lasted from 1 year and 11 months up to 3 years and 11 months. Lower anterior crowding was measured using Little’s irregularity index. Measurements were obtained on study models achieved before and after functional orthopedic therapy, using a digital caliper in millimeters and placed parallel to the occlusal plane. Overjet and overbite measurements were also performed using a caliper. Results demonstrated that the therapy provided significant decrease in overjet (average = 1.55 mm) and also in the irregularity index (average = 1.23 mm). There was a nonsignificant raise in overbite. There was no relation between the studied variables and the treatment period or even with the patient’s age in the beginning of the therapy. The treatment with T4k resulted on reduction and improvement of dental crowding.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to evaluate the stability of the conservative condylectomy technique and articular disc repositioning as the surgical treatment approach for management of mandibular condylar osteochondroma, with appropriate Orthognathic surgery. Fifteen patients (12 females and 3 males), average age of 32.3 years (range, 13 to 56 years), with unilateral active osteochondroma of the mandibular condyle were analyzed. All patients underwent conservative condylectomy, recontouring of the remaining condylar neck stump and articular disc repositioned and indicated orthognatic surgical procedures. Average post surgical follow-up was 19 months. Each patient's lateral cephalograms were traced at 3 intervals (presurgery, immediate post surgery and long-term follow-up). Immediate after surgery the oclusal plane angle decreased -2.8 ± 4.5o, the maxillomandibular complex rotated counter-clockwise with advancement at menton 5.3 ± 5.6 mm, pogonion 5.0 ± 5.1 mm, B point 3.4 ± 4.2 mm and A point 1.0 ± 1.5 mm. The long-term follow-up showed significant changes in overbite (-0.6 ± 0.5 mm) and SNGoMe (0,93° ± 1,53°). Horizontally and vertically small instabilities occurred in Me (-1.21 ± 1.94 mm) and PNS (-1.48 ± 1.67 mm) respectively. The treatment protocol studied produced counterclockwise rotation and maxillofacial mandibular advancement. The long-term follow-up showed solid dental and skeletal stability with horizontal instability of Me and PNS in the vertical direction.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Immediate functioning of osseointegrated implants has been widely employed in edentulous patients due to its safety and high predictability. However, viability and success of immediate-loaded implants is defined by factors such as number of implants, distribution and splinting, as well as reduction of oblique loads and excessive occlusal contacts. The indirect composite resin-modified glass enable building of a highly aesthetic prosthesis, combining satisfactory resistance and better force dissipation on occlusal loading. This article describes a resin composite, mandibular fixed prosthesis on osseointegrated implants in immediate function.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The Combination Syndrome represents an important pathologic condition of the masticatory system that requires a complex rehabilitation treatment. The presence of flaccid mucosa is one of the most common features due to bone resorption of the pre-maxilla caused by anterior hyperfunction of the mandibular teeth on the maxillary complete denture, where the impact of oclusal loading in this region results in movement of the maxillary prosthesis into the ridge, resulting in increased resorption of the residual ridge, internal misfit and loss of the retention of the maxillary complete denture. The presence of flaccid mucosa, in such cases, leads to problems of support and stability of the maxillary complete denture, which can be treated by surgical reduction of the thickness of the tissue or using specific techniques of fabrication of prostheses. This article describes the oral rehabilitation of a patient with the Combination Syndrome where the surgical reduction of flaccid mucosa was not performed, using a modified technique of functional impression in two steps, with the objective of generating forces and less distortion in flaccid mucosa during functional impression.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The success achieved by the use of composite resins in anterior teeth precipitately leads their use in posterior teeth. However, the indiscriminate application of these materials in cavities with several diverse sizes rapidly pointed out their lack of resistance to oclusal and proximal wear. OBJECTIVE: To evaluate the surface roughness of composite resin in relation to finishing and polishing technique. MATERIAL AND METHODS: Eight experimental groups (n = 15) were divided according to finishing and polishing technique: G1 – Z250TM composite resin without surface finishing and polishing; G2 – Z250TM composite resin plus surface finishing and polishing; G3 – P60TM composite resin without surface finishing and polishing; G4 – P60TM composite resin plus surface finishing and polishing; G5 – Prodigy CondensableTM composite resin without surface finishing and polishing; G6 – Prodigy CondensableTM composite resin plus surface finishing and polishing; G7 – SurefillTM composite resin without surface finishing and polishing; G8 – SurefillTM composite resin plus surface finishing and polishing. Three packable and one microhybrid (control group) composite resin was used. The surface roughness was measured using a profilometer at three points in each sample. The results were evaluated by ANOVA and Tukey test (p < 0.05). RESULTS: Prodigy CondensableTM composite resin showed the lowest surface roughness, while SurefillTM showed the highest surface roughness. Comparing the resins used, only between P60TM and SurefillTM there were no statistically significant differences (p > 0,05). CONCLUSION: Surface roughness was lower in all types of resin composites surfaces in contact with Mylar matrix strip than in areas submitted to finishing and polishing procedure.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The present study evaluated the radiopacity and flow of different endodontic sealers: AH Plus, Endo CPM, MTA Fillapex, Sealapex, Epiphany, and Epiphany SE. For the radiopacity test, six specimens measuring 10mm in diameter and 1mm in thickness were fabricated from each material. They were radiographed on an occlusal film alongside an aluminum step wedge. Radiographs were digitized to determine the radiopacity equivalence in millimeters of aluminum. To evaluate the flow, a 120 g load was placed on top of a glass slab containing 0.05 } 0.005ml of sealer. The diameters of each material were measured (mm) with a caliper and samples were photographed. Digitized images were analyzed using the UTHSCSA Image Tool for Windows software, to determine the sealer area (mm2). Data were submitted to ANOVA and Tukey's test at 5% significance. AH Plus and Epiphany SE presented the greatest radiopacity (12.5 mm Al and 12.0 mm Al, respectively) (p>0.05), followed by Epiphany (9.6 mm Al) and Fillapex (8.9 mm Al). Endo CPM (5.46 mm Al) and Sealapex (5.51 mm Al) presented lower radiopacity. MTA Fillapex presented significantly higher values of flow than other sealers (33.11 mm and 844.9 mm2). AH Plus, Epiphany, and Epiphany SE had similar values. Endo CPM (21.05 mm and 342.8 mm2) and Sealapex (19.98 mm and 352.5 mm2) presented the lowest flow values (p>0.05). All sealers presented radiopacity and flow values according to ISO and ANSI/ADA recommendations.