350 resultados para Two way ranging protocol
Resumo:
Pós-graduação em Reabilitação Oral - FOAR
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The severity of Parkinson's disease (PD) and PD's motor subtypes influence the components of physical capacity. The aim of this study was to investigate the impact of both PD severity and motor subtype in the performance of these components. Thirty-six PD patients were assigned into four groups: Tremor (TD) initial and TD mild, akinetic-rigid (AR) initial, and AR mild. Patients' strength, balance, coordination, mobility and aerobic capacity were evaluated and groups were compared using a two-way ANOVA (severity and subtype as factors). AR presents a poorer performance than TD in almost all tests. Also this performance was worsened with the advance of the disease in AR, contrary to TD. We conclude that AR and TD subgroups are different about their performance on physical capacity components, moreover, this performance worsens with the advance of the disease of the AR group, but not for TD.
Color Stability of Resin Used for Caries Infiltration After Exposure to Different Staining Solutions
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Objectives: To investigate the reliability of regional three-dimensional registration and superimposition methods for assessment of temporomandibular joint condylar morphology across subjects and longitudinally.Methods: The sample consisted of cone beam CT scans of 36 patients. The across-subject comparisons included 12 controls, mean age 41.3 +/- 12.0 years, and 12 patients with temporomandibular joint osteoarthritis, mean age 41.3 +/- 14.7 years. The individual longitudinal assessments included 12 patients with temporomandibular joint osteoarthritis, mean age 37.8 +/- 16.7 years, followed up at pre-operative jaw surgery, immediately after and one-year post-operative. Surface models of all condyles were constructed from the cone beam CT scans. Two previously calibrated observers independently performed all registration methods. A landmark-based approach was used for the registration of across-subject condylar models, and temporomandibular joint osteoarthritis vs control group differences were computed with shape analysis. A voxel-based approach was used for registration of longitudinal scans calculated x, y, z degrees of freedom for translation and rotation. Two-way random intraclass correlation coefficients tested the interobserver reliability.Results: Statistically significant differences between the control group and the osteoarthritis group were consistently located on the lateral and medial poles for both observers. The interobserver differences were <= 0.2 mm. For individual longitudinal comparisons, the mean interobserver differences were <= 0.6 mm in translation errors and 1.2 degrees in rotation errors, with excellent reliability (intraclass correlation coefficient >0.75).Conclusions: Condylar registration for across-subjects and longitudinal assessments is reliable and can be used to quantify subtle bony differences in the three-dimensional condylar morphology.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
This study assessed the effect of different etching durations of feldspathic ceramic with hydrofluoric acid (HF) and ultrasonic cleaning of the etched ceramic surface on the microtensile bond strength stability of resin to a feldspathic ceramic. The research hypotheses investigated were: (1) different etching times would not affect the adhesion resistance and (2) ultrasonic cleaning would improve the adhesion. Ceramic blocks (6 x 6 x 5 mm) (N = 48) were obtained. The cementations surfaces were duplicated in resin composite. The six study groups (n = 8) were: G1Etching with 10% aqueous HF (30 s) + silane; G 210% HF (1 min) + silane; G3-10% HF (2 min) + silane; G4-10% HF (30 s) + ultrasonic cleaning (4 min) in distilled water + silane; G5-10% HF (1 min) + ultrasonic cleaning + silane; G6-10% HF (2 min) ultrasonic cleaning + silane. The cemented blocks were sectioned into microbars for the microtensile test. The etching duration did not create significant difference among the groups (p = .156) but significant influence of ultrasonic cleaning was observed (p = .001) (Two-way ANOVA and Tukey's test, p > 0.05). All the groups after ultrasonic cleaning presented higher bond strength (19.38-20.08 MPa) when compared with the groups without ultrasonic cleaning (16.2117.75 MPa). The bond strength between feldspathic ceramic and resin cement was not affected by different etching durations using HF. Ultrasonic cleaning increased the bond strength between ceramic surface and resin cement, regardless of the etching duration.
Resumo:
Objective: This study evaluated the influence of different surface treatments on the resin bond strength/light-cured characterizing materials (LCCMs), using the intrinsic characterization technique. The intrinsic technique is characterized by the use of LCCMs between the increments of resin composite (resin/thin film of LCCM/external layer of resin covering the LCCM).Materials and Methods: Using a silicone matrix, 240 blocks of composite (Z350/3M ESPE) were fabricated. The surfaces received different surface treatments, totaling four groups (n=60): Group C (control group), no surface treatment was used; Group PA, 37% phosphoric acid for one minute and washing the surface for two minutes; Group RD, roughening with diamond tip; and Group AO, aluminum oxide. Each group was divided into four subgroups (n=15), according to the LCCMs used: Subgroup WT, White Tetric Color pigment (Ivoclar/Vivadent) LCCM; Subgroup BT, Black Tetric Color pigment (Ivoclar/Vivadent) LCCM; Subgroup WK, White Kolor Plus pigment (Kerr) LCCM; Subgroup BK, Brown Kolor Plus pigment (Kerr) LCCM. All materials were used according to the manufacturer's instructions. After this, block composites were fabricated over the LCCMs. Specimens were sectioned and submitted to microtensile testing to evaluate the bond strength at the interface. Data were submitted to two-way analysis of variance (ANOVA) (surface treatment and LCCMs) and Tukey tests.Results: ANOVA presented a value of p<0.05. The mean values (+/- SD) for the factor surface treatment were as follows: Group C, 30.05 MPa (+/- 5.88)a; Group PA, 23.46 MPa (+/- 5.45)b; Group RD, 21.39 MPa (+/- 6.36)b; Group AO, 15.05 MPa (+/- 4.57)c. Groups followed by the same letters do not present significant statistical differences. The control group presented significantly higher bond strength values than the other groups. The group that received surface treatment with aluminum oxide presented significantly lower bond strength values than the other groups.Conclusion: Surface treatments of composite with phosphoric acid, diamond tip, and aluminum oxide significantly diminished the bond strength between composite and the LCCMs.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Objective: The aim of the present study was to evaluate the effect of pursed-lip breathing (PLB) on cardiac autonomic modulation in individuals with chronic obstructive pulmonary disease (COPD) while at rest. Methods: Thirty-two individuals were allocated to one of two groups: COPD (n = 17; 67.29 +/- 6.87 years of age) and control (n = 15; 63.2 +/- 7.96 years of age). The groups were submitted to a two-stage experimental protocol. The first stage consisted of the characterization of the sample and spirometry. The second stage comprised the analysis of cardiac autonomic modulation through the recording of R-R intervals. This analysis was performed using both nonlinear and linear heart rate variability (HRV). In the statistical analysis, the level of significance was set to 5% (p = 0.05). Results: PLB promoted significant increases in the SD1, SD2, RMSSD and LF (ms(2)) indices as well as an increase in alpha(1) and a reduction in alpha(2) in the COPD group. A greater dispersion of points on the Poincare plots was also observed. The magnitude of the changes produced by PLB differed between groups. Conclusion: PLB led to a loss of fractal correlation properties of heart rate in the direction of linearity in patients with COPD as well as an increase in vagal activity and impact on the spectral analysis. The difference in the magnitude of the changes produced by PLB between groups may be related to the presence of the disease and alterations in the respiration rate.
Resumo:
Pós-graduação em Reabilitação Oral - FOAR
Resumo:
Pós-graduação em Odontologia - FOAR
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
O objetivo deste estudo in vitro foi comparar os efeitos da fotoativação pelos sistemas luz halógena e LED na adesão de braquetes ortodônticos em diferentes tempos pós-colagem (imediato, 24h e 7d). Braquetes com adesivo pré-aplicado (Gemini series; APC adhesive precoated brackets; 3M Unitek, USA) foram colados na superfície vestibular de dentes bovinos. O esmalte dos dentes foi condicionado utilizando-se o primer auto-condicionante (Transbond SEP, 3M Unitek, USA) em todos os espécimes, conforme recomendações do fabricante. Setenta e dois dentes foram divididos em 2 grupos (n=36), conforme o sistema de fotoativação (luz halógena ou LED) e sub-divididos (n=12) de acordo com o tempo pós-colagem. Para os grupos luz halógena, o tempo de fotoativação foi de 20s e para os grupos LED foi de 10s. O teste de resistência ao cisalhamento foi realizado com auxílio de uma máquina de ensaios universal nos diferentes tempos pós-colagem: imediato, 24h e 7d. O valor médio de adesão para os grupos luz halógena foi de 20,01±5,24MPa e, para os grupos fotoativados pelo sistema LED 17,35±5,07MPa, sendo estes resultados estatisticamente diferentes. Quando comparado o efeito do tempo pós-colagem, os resultados revelaram que os valores de adesão foram significantemente maiores para o tempo de 7d. O resultado do teste ANOVA 2 – fatores revelou não existir diferença estatística entre a interação sistema de fotoativação e tempos pós-colagem. O teste de Tukey mostrou que para as 4 condições experimentais nos tempos imediato e 24h, os resultados não diferiram estatisticamente, independentemente do sistema de fotoativação. Somente com relação ao grupo luz halógena-7d, os resultados mostraram diferenças estatisticamente significantes. O grupo LED-7d desempenhou comportamento intermediário entre os grupos. O índice de adesivo remanescente não revelou diferenças... (Resumo completo, clicar acesso eletrônico abaixo)