286 resultados para Electron microscopy (TEM and SEM)
Resumo:
Pós-graduação em Química - IQ
Resumo:
Statement of problem Because zirconia is a glass-free material, alternative surface treatments such as airborne-particle abrasion or silica coating should be used for long-term bonding. However, these surface treatments in combination with different bonding agents and luting cements have not yet been studied. Purpose The purpose of the study was to evaluate the effect of surface treatments on the shear bond strength (SBS) of luting cements to Y-TZP ceramic. Material and methods Zirconia disks (N=240) were airborne-particle abraded with the following particles (n=48): 50 μm Al2O3; 120 μm Al2O3; 30 μm silica-coated Al2O3 (Rocatec Soft); 120 μm Al2O3+110 μm silica-coated Al2O3 (Rocatec Plus); and Rocatec Plus. After silanization of the zirconia surface, composite resin disks were bonded with (n=12) RelyX Luting 2; RelyX ARC; RelyX U100; and Panavia F. The bonded specimens were thermocycled (10 000 cycles) and tested for SBS. Failure mode was determined with a stereomicroscope (×20). The morphology and elemental composition of airborne-particle abraded surfaces were evaluated with scanning electron microscopy (×500) and energy-dispersive x-ray spectroscopy (×50). Results Surface treatments, cements, and their interaction were significant (P<.001). For RelyX ARC, Rocatec Soft and Rocatec Plus provided the highest SBS. In general, surface treatments did not influence the SBS of RelyX U100 and Panavia F. Regardless of the cement, no significant difference was found between 50 μm and 120 μm Al2O3 particles, between Rocatec Soft and Rocatec Plus, or between Rocatec Plus and 120 μm Al2O3 particles+Rocatec Plus. All groups showed adhesive failures. Different particle sizes provided differences in morphological patterns. The elemental composition comprised Al and Al/Si for alumina and silica-abraded zirconia. Conclusions Particle size did not influence the SBS of the groups abraded exclusively with alumina or silica-coated particles. RelyX ARC was more surface-treatment dependent than RelyX U100 or Panavia F.
Resumo:
Endodontic sealer residues on dentinal surface have negative effects on adhesion of adhesives system and/or can cause discoloration of the dental crown. Objective: To evaluate the efficacy of 95% ethanol in removal of residues of epoxy-based (AH Plus), methacrylate-based (Epiphany SE) or calcium-based (Sealapex) sealers on dentinal surface. Material and methods: Thirty-two bovine incisor dental crown fragments (0.5 mm x 0.5 mm) were treated with 17% EDTA and 2.5% NaOCl. The specimens were divided into three experimental groups (n = 10): G1 (AH Plus), G2 (Epiphany SE) and G3 (Sealapex). In each group was applied a coating of one endodontic sealer type and were left undisturbed for 5 minutes. After this period, the specimens were cleaned with 95% ethanol. The control group was composed by two specimens that did not receive any sealer or cleaning treatment. The sealer residues persistence after cleaning with 95% ethanol was evaluated by scanning electron microscopy (x500) and a score system was applied. Data obtained were analyzed by Kruskal-Wallis and Dunn tests (α = 5%). Results: Moderate amount of endodontic sealer residues were observed in all groups, regardless of the endodontic sealer compositions. G1, G2 and G3 presented similar amount of sealer residues on dentinal surface after cleaning with 95% ethanol (p > 0.05). Conclusion: 95% ethanol was inefficiency to remove completely AH Plus, Epiphany SE and Sealapex residues of sealer-contaminated dentin.
Resumo:
Introduction: Endodontic sealer residues on dentinal surface have negative effects on adhesion of adhesives system and/or can cause discoloration of the dental crown. Objective: To evaluate the efficacy of 95% ethanol in removal of residues of epoxy-based (AH Plus), methacrylate-based (Epiphany SE) or calcium-based (Sealapex) sealers on dentinal surface. Material and methods: Thirty-two bovine incisor dental crown fragments (0.5 mm x 0.5 mm) were treated with 17% EDTA and 2.5% NaOCl. The specimens were divided into three experimental groups (n = 10): G1 (AH Plus), G2 (Epiphany SE) and G3 (Sealapex). In each group was applied a coating of one endodontic sealer type and were left undisturbed for 5 minutes. After this period, the specimens were cleaned with 95% ethanol. The control group was composed by two specimens that did not receive any sealer or cleaning treatment. The sealer residues persistence after cleaning with 95% ethanol was evaluated by scanning electron microscopy (x500) and a score system was applied. Data obtained were analyzed by Kruskal-Wallis and Dunn tests (α = 5%). Results: Moderate amount of endodontic sealer residues were observed in all groups, regardless of the endodontic sealer compositions. G1, G2 and G3 presented similar amount of sealer residues on dentinal surface after cleaning with 95% ethanol (p > 0.05). Conclusion: 95% ethanol was inefficiency to remove completely AH Plus, Epiphany SE and Sealapex residues of sealercontaminated dentin.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Pós-graduação em Engenharia Mecânica - FEIS
Resumo:
Pós-graduação em Ciência dos Materiais - FEIS
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Neste trabalho investigou-se a modificação de superfície do titânio pela irradiação com feixe de Laser Nd:YAG. Os parâmetros do laser como a potência, o comprimento de onda, a frequência, a velocidade de varredura e a área de exposição foram mantidos constantes, exceto o espaçamento da matriz, o qual foi de 0,01 e 0,02 mm. A caracterização da superfície foi realizada por Microscopia Eletrônica de Varredura (MEV) e Difração de Raios X (DRX), sendo que os espectros foram refinados pelo método Rietveld. Pela análise de MEV, observou-se uma mudança na topografia, obtendo uma superfície rugosa produzida pelo fenômeno de ablação. As análises por Rietveld dos espectros de difração de raios X detectaram TiN, Ti2N, TiO2 (anatásio e rutilo), sendo que a amostra com espaçamento 0,01 mm apresentou uma maior quantidade de óxidos e nitretos. Isso pode ser devido à sobreposição do feixe, induzindo à formação de uma superfície com maior estabilidade termodinâmica. Os óxidos e nitretos obtidos são de grande importância, pois são responsáveis por produzir uma maior interação entre o osso-implante.
Resumo:
Pós-graduação em Ciência dos Materiais - FEIS
Resumo:
Pós-graduação em Biociências e Biotecnologia Aplicadas à Farmácia - FCFAR
Resumo:
Pós-graduação em Ciência dos Materiais - FEIS
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)