312 resultados para Dental Infection control


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This retrospective study analyzed the HLA-B*27 alleles in a group of 20 consecutive patients with the diagnosis of Reiter syndrome (RS) followed in a tertiary referral university hospital in Brazil, during the period 1990-2006, and compared the data with that observed in other patients with spondyloarthropathies followed at the same institution. Eight cases were associated to gastrointestinal infection, eight cases to previous urethritis, and four cases presented no established preceding infection. HLA-B*27 alleles were typed by polymerase chain reaction-amplified DNA hybridized with sequence-specific oligonucleotide probes (HLA-B*2701 to HLA-B*2721). They were compared to a group of 108 patients with ankylosing spondylitis (AS), 40 with undifferentiated spondyloarthropathy (uSpA) and 111 healthy controls. Among the 20 patients, 17 were HLA-B*27 positive (85%). Two HLA-B*27 alleles were observed: HLA-B*2705 (65%) and HLA-B*2702 (35%). In the other spondyloarthropathies, the observed alleles were HLA-B*2705 (90% in AS and 92.5% in uSpA), HLA-B*2702 (8% in AS and 5% in uSpA), HLA-B*2704 (1% in AS and 2.5% in uSpA) and HLA-B*2713 (1% in AS). Among the 111 healthy controls, 80% presented HLA-B*2705, followed by HLA-B*2702 in 10%, HLA-B*2703 in 6%, HLA-B*2707 in 3% and HLA-B*2713 in 1%. Concluding, in the HLA-B*27 positive patients with RS in this study there was predominance of HLA-B*2705 allele, in a lower frequency than that observed in patients with other spondyloarthropathies and healthy controls.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective. To determine the effects of different aging methods on the degradation and flexural strength of yttria-stabilized tetragonal zirconia (Y-TZP)Methods. Sixty disc-shaped specimens (0, 12 mm; thickness, 1.6 mm) of zirconia (Vita InCeram 2000 YZ Cubes, VITA Zahnfabrik) were prepared (ISO 6872) and randomly divided into five groups, according to the aging procedures (n=10): (C) control; (M) mechanical cycling (15,000,000 cycles/3.8 Hz/200N); (T) thermal cycling (6,000 cycles/5-55 degrees C/30 s); (TM) thermomechanical cycling (1,200,000 cycles/3.8 Hz/200N with temperature range from 5 C to 55 C for 60s each); (AUT) 12h in autoclave at 134 degrees C/2 bars; and (STO) storage in distilled water (37 degrees C/400 days). After the aging procedures, the monoclinic phase percentages were evaluated by X-ray diffraction (XRD), and topographic surface analysis was performed by 3D profilometry. The specimens were then subjected to biaxial flexure testing (1 mm/min, load 100 kgf, in water). The biaxial flexural strength data (MPa) were analyzed by 1-way ANOVA and Tukey's test (alpha = 0.05). The data for monoclinic phase percentage and profilometry (Ra) were analyzed by Kruskal-Wallis and Dunn's tests.Results. ANOVA revealed that flexural strength was affected by the aging procedures (p = 0.002). The M (781.6 MPa) and TM (771.3 MPa) groups presented lower values of flexural strength than did C (955 MPa), AUT (955.8 MPa), T (960.8 MPa) and STO (910.4 MPa). The monoclinic phase percentage was significantly higher only for STO (12.22%) and AUT (29.97%) when compared with that of the control group (Kruskal-Wallis test, p = 0.004). In addition, the surface roughnesses were similar among the groups (p = 0.165).Signcance. Water storage for 400 days and autoclave aging procedures induced higher phase transformation from tetragonal to monoclinic; however, they did not affect the flexural strength of Y-TZP ceramic, which decreased only after mechanical and thermomechanical cycling. (C) 2014 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Feeding strategies that reduce feed and promote compensatory growth could be an interesting tool to reduce costs in the fish production. However, fish health must be monitored to evaluate if their physiological response to adverse conditions, such as parasite infection, does not become compromised. A 12-wk growth trial was conducted to determine the physiological responses of pacu, Piaractus mesopotamicus, that were subjected to different fasting/refeeding cycles and infected with the Dolops carvalhoi. The schemes were: (i) control group fish (FD), (ii) food-restricted and controlled refeeding group (FR/Rc), and (iii) food-restricted and refeeding to satiation group (FR/Rs). After 84 d, the fish were exposed to D. carvalhoi for 30 h. The fish subjected to food restriction did not exhibit compensatory growth. Cortisol levels decreased in all groups within 30 h after infection. Glucose levels increased 6 h after the D. carvalhoi in the FR/Rs and 30 h after infection in the FD. In all of the fish groups, the hematocrit values were reduced after infection, and it was associated with a reduction in the mean corpuscular volume and erythrocytes. At 30 h after infection, the number of erythroblasts increased. The use of the feeding schemes does not indicate a failure of the pacu physiological responses.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The head is the most important and specialized region in the body because it contains a range of specialized organs and, because it has interconnections between specialized organs, there is a great overlap of images. Thus, computed tomography (CT) helps in diagnosing diseases in this region, such as oral conditions, as they provide millimetric slices or cuts and demonstrate the relationship between the various anatomical structures involved, in volume and depth. Within dentistry, CT helps in the identification of pathological processes such as infection, tumors, visualization of embedded teeth and bone bed. This study aimed to assess the density of the mandibular alveolar bone at a determined point to later predict how periodontal disease is involved in bone resorption. For this, we performed a blind retrospective study (n = 124) of the CT scan files of dog skulls at FMVZ-UNESP in order to determine the density of the jaw bone using a Hounsfield scale, in the region of the dental apex of the cranial root of the first molar tooth in dogs. The results obtained were evaluated using mean and standard deviation (27.28 +/- 9.53 HU) in order to predict the normal density of the mandibular alveolar bone in the studied region. Thus, this data analysis allows a more concise evaluation of bone resorption of mandibular alveolar bone and, therefore, provides an adequate surgical planning in cases of osteosynthesis given mainly by the presence of installed periodontal disease.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

To evaluate the effect of surface treatment with Er:YAG and Nd:YAG laser on resin composite bond strength to recently bleached dentin. Material and Methods: In this study 120 bovine incisors were used and distributed into two groups: Group C: without bleaching treatment; Group B: with bleaching treatment (35% hydrogen peroxide). Each group was divided into three subgroups: Subgroup N: without laser treatment; Subgroup Nd: irradiation with Nd:YAG laser; Subgroup Er: irradiation with Er:YAG laser. Next, the adhesive system (Adper Single Bond 2) was applied and composite buildups were constructed with Z350 composite. The teeth were sectioned to obtain dentin-resin sticks (1x1mm) and analyzed by microtensile bond testing. The data were statistically analyzed by the ANOVA and Tukey tests. Results: The results showed that the bond strength values in the bleached control group (16.17 MPa) presented no significant difference in comparison with the group bleached and irradiated with Er:YAG laser (14.69 MPa). The non bleached control group (26.79 MPa) presented significant difference in bond strength when compared with the non bleached group irradiated with Er:YAG laser (22.82 MPa) and with the group treated by bleaching and irradiation with Nd:YAG laser (28,792 MPa). The group without bleaching treatment and irradiated with Nd:YAG (36.1 MPa) presented a significant increase in bond strength in comparison with the other groups. Conclusion: The use of Nd:YAG laser on bleached specimens was able of completely reversing the immediate effects of bleaching, obtaining bond strength values similar to those of the control group

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)