253 resultados para Transferência de carga
Resumo:
In spite of education it was not main element of Freud's work, in elapsing of work he considered it in chapter denominated “Education Interest of the psychoanalysis” (1913). The objective is to intend to the teacher to consider the importance of psychoanalytic focus in pedagogic extent, demonstrating her contribution for understanding of the students' formative processes. Consequently, to contemplate, starting from the Freudian work, on transfer concept in that relationship introducing intervention forms in the teaching process and learning. We adopted the revision of literature related to the psychoanalytic aspect that it approaches the education, in interface with school physical education. In other words, we specifically looked for aspects on the theme of transfer in the interface of psychoanalysis with pedagogy. Also, part of the Freudian work was used regarding the theme approached in analytical indexes. Since then, we detected that the observed authors affirm that between teachers and students relationship transferencial exists. Therefore, the selection of contents sends the educators to organize and systematize as it will be worked in curriculum and transmitted to the students, since it should go to the encounter of students’ expectations, doing with that school physical education has sense and meaning. Therefore, it is important the physical education teacher, in school, to analyze that when working with the human being there are just no effects of work on content or about the use of correct teaching methodology, but, also the actions transferenciais that are present in learning process.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Tradicionalmente a prescrição de exercícios físicos é baseada unicamente em relação à carga externa. Entretanto, as adaptações fisiológicas em função do treinamento físico dependem da carga interna. Assim, a carga interna deve ser levada em consideração para uma otimização da prescrição exercícios físicos, principalmente durante exercícios em grupos que normalmente são utilizados para a população idosa. Porém, o envelhecimento parece acarretar em deteriorações na capacidade de interocepção, colocando em questionamento a validade de um dos principais métodos de quantificação da carga interna, o método que utiliza a percepção subjetiva de esforço (PSE). Desse modo, o objetivo do presente estudo foi comparar os métodos de quantificação da carga interna que utilizam a frequência cardíaca (FC), considerado o padrão-ouro para o presente estudo, com o método que utiliza a PSE na população idosa. Quarenta idosos praticantes de ginástica aeróbia (A) ou musculação (M) foram avaliados durante uma sessão de exercícios físicos. A determinação da carga interna pela FC e pela PSE foram realizadas através dos métodos de Edwards e de Foster, respectivamente. Os valores de carga interna (expressos em unidades arbitrárias) calculados pelo método da FC e PSE foram 69,4 ± 40,0 e 151,5 ± 83,5 para o grupo M e 73,3 ± 37,1 e 134,7 ± 41,6 para o grupo A, respectivamente. O valor de carga interna para os dois grupos em conjunto foi de 71,3 ± 38,2 pelo método da FC e de 143,1 ± 65,7 pela PSE. A relação entre os métodos foi determinada usando-se o coeficiente de correlação de Pearson para todos os participantes em conjunto (T), assim como para os grupos M e A. As correlações encontradas foram de r = 0,33 (p < 0,05) para T, r = 0,37 (p = 0,11) para M e r = 0,32 (p = 0,17) para A. A moderada correlação obtida coloca em questão a utilização do método da PSE para a quantificação de carga interna...
Resumo:
Pós-graduação em Agronomia (Ciência do Solo) - FCAV
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Análise parâmetros elétricos consumo, fator de carga e demanda de empresas de refino de óleo vegetal
Resumo:
Empresas muitas vezes tem seu consumo de energia elétrica descontrolados por possuírem motores elétricos muitas vezes super-dimensionados, trabalhando em vazio ou em horário de pico. Sendo este tipo de atividade responsável por grande parte do gasto energético da empresa. Existem dois fatores que avaliam o modo de utilização desta energia, denominados fator de potência (fp) e fator de carga (fc), que indicam a eficiência e racionalidade da forma de utilização da energia elétrica, respectivamente. A necessidade de uma avaliação global da utilização da energia, levando em consideração os dois fatores citados, é realizada por especialistas da área energética para a determinação da situação real da empresa. Podendo ser uma tarefa árdua muitas vezes demorada. Para isto é necessária uma análise estatística descritiva dos dados. Este trabalho tem como objetivo realizar esta analise de dados de uma empresa de refino de óleo vegetal.
Resumo:
In the pumping pipelines the located load losses are very important since they have direct influence on hydraulic design of an irrigation system, especially regarding the concentric reducers used in the distribution lines. Hence this work was conducted in the Laboratório de Hidráulica do Centro Federal de Educação Tecnológica de Uberaba. We analyzed 03 concentric reducers PVC 75 x 50 mm, 50 mm and 35 x 35 x 1 "operating at different flow rates. The performance of the tests with the variation of flow in every situation possible to obtain equations to estimate the loss. The equation models presented a high setting, thus enabling the determination of the localized head loss in a situation closer to field reality. For the reduction of 75 x 50 x 35 mm and 50 mm at a flow rate 16.97 m³ h-1 the pressure drop reduction was obtained respectively 0.9263 and 2.7408 mca. To the reduction of 35 x 1 "at a flow rate of 6.02 m³ h-1 was obtained 2.9304 mca pressure drop reduction. The located losses produced by these reductions are relatively high and should be considered with great discretion in hydraulic design of the irrigation system.
Resumo:
No-till has been used in many different regions of Brazil. However, depending on the location and intensity of machinery traffic, this has caused the problem of soil compaction and many producers are scarification the land as a solution to break through the layer that is restricting plant growth. The objective of this study was to evaluate the influence of scarification (0.30 m) in the physical properties of a dystrophic Alfisol comparing the results with a non-scarified contiguous area; both were previously conducted using no-till. The density and pressure of pre-consolidation were sampled in two areas of non-tillage, one with chiseling (PDCE) and one without (PDSE) by using the UMAS -Mobile Soil Sampling Unit built by NEMPA – Agroforestry Machinery and Tire Testing Center/FCA / UNESP, Botucatu ,SP. The UMAS is equipped with GPS which allows the samples to be georeferenced. The samples were evaluated in the laboratory through the collection of standardized rings. Sampling was performed at a dimension of 15 x 50 m, with 160 rings being collected. The samples containing rings which were used in determining the density and also for testing the consolidometer, were collected from the layers of 0 to 0.10 m, 0.10 to 0.20 m, 0.20 to 0.30 0.30 to I 0.40 m. For the odometer test the undisturbed sample rings were used in obtaining the load bearing capacity of the soil. The soil management adopted provided a decrease in soil density using no-tillage with scarification depths from 0.0 to 0.10 0.10 to 0.20 m while the other depths did not show any decrease. The pre-consolidation pressure in combination with soil aggregate resistance identified that the management process PDCE within all layers was subjected to water content reliability regarding a greater load bearing capacity of the soil. For the PDSE that only was possible in the 0 to 0.10 m, showing greater consolidation of this layer.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
In Geotechnical engineering the foundation projects depend on the bearing capacity and the acceptable displacements. One of the possible ways to predict the bearing capacity of foundations is through semi-empirical statistical methods which correlate in-situ tests (SPT and CPT). The piles breaking loads are defined by the interpretation of the load x head displacement curve and the experimental data acquired through the load test. In this work it is studied the behavior of bored piles executed in the Araquari/SC region, comparing the bearing capacity values predicted by the methods DECOURT & QUARESMA MODIFICADO (1996), AOKI & VELLOSO MODIFICADO MONTEIRO (2000), MILITITISKY E ALVES (1985), DECOURT & QUARESMA (1978), MÉTODO DE AOKI & VELLOSO (1975) e PHILOPANNAT (1986), with the results of the load test, evaluating their differences and discussing parameters that have direct effects on the prediction