701 resultados para NETTRA-G3-FIFO
Resumo:
Purpose: To evaluate a bone morphogenetic protein (BMP) implant with and without platelet-rich plasma (PRP), which is supposed to accelerate fracture consolidation in the orbit fracture treatment. Methods: Thirty-six white rabbits were subjected to orbital fracture and treated in three groups: BMP implant fracture repair (G1), BMP plus PRP implant fracture repair (G2), and fracture and spontaneous repair (G3). The animals were sacrificed at 7, 30, 90, and 180 days after surgery. A radiology evaluation was carried out on the 7th day after the fracture and at the sacrifice moments. After the animals' death, the orbital content material was removed and prepared for morphological and morphometric analysis. Results: Radiology suggested intramembranous and progressive cavitation and ossification without a reduction in implant size and with signs of calcium deposition; these events were confirmed by histological analysis, which showed a lymphomononuclear inflammatory reaction in G1 and G2, more intense 7 days after surgery and reducing after 30 days. Associating PRP with BMP did not accelerate bone induction. Conclusion: BMP implant promotes bone induction, integration at fracture site, scarce inflammatory reaction, and may be a good alternative in orbit fracture reconstruction. The addition of PRP to the BMP plate did not accelerate the resolution, and its use is not necessary. Copyright © Informa Healthcare USA, Inc.
Resumo:
The aim of this study was to evaluate the urinary fluoride excretion of 2- to 7-year-old children exposed to different water fluoride concentrations in the city of Catolé do Rocha, PB, Brazil. Forty-two children were allocated to 3 groups according to the concentration of fluoride in the water: G1 (n=10; 0.5-1.0 ppm F), G2 (n=17; 1.1-1.5 ppm F) and G3 (n= 15; >1.51 ppm F). The study was carried out in two 1-week phases with 1-month interval between the moments of data collection: in the first phase, the children used a fluoride toothpaste (FT) (1,510 ppm F) for 1 week, whereas in the second phase a non-fluoride toothpaste (NFT) was used. The urine was collected in a 24-h period in each week-phase according to Marthaler's protocol. The urinary fluoride excretion data expressed as mean (SD) in ì g/24 h were: G1-FT= 452.9 (290.2); G1-NFT= 435.1 (187.0); G2-FT= 451.4 (224.0); G2-NFT= 430.3 (352.5); G3-FT=592.3 (390.5); and G3-NFT=623.6 (408.7). There was no statistically significant difference between the water fluoride groups, and regardless of the week phase (ANOVA, p>0.05). The use of fluoride toothpaste (1,510 ppmF) did not promote an increase in urinary fluoride excretion. There was a trend, though not significant, as to the increase of urine fluoride concentration in relation to fluoride concentrations in the water. The excretion values suggest that some children are under risk to develop dental fluorosis and information about the appropriate use of fluoride is necessary in this area.
Resumo:
This study evaluated the effect of mechanical cycling on the bond strength of zirconia posts to root dentin. Thirty single-rooted human teeth were transversally sectioned to a length of 16 mm. The canal preparation was performed with zirconia post system drills (CosmoPost, Ivoclar) to a depth of 12 mm. For post cementation, the canals were treated with total-etch, 3-steps All-Bond 2 (Bisco), and the posts were cemented with Duolink dual resin cement (Bisco). Three groups were formed (n = 10): G1 - control, no mechanical cycling; G2 - 20,000 mechanical cycles; G3 - 2,000,000 mechanical cycles. A 1.6-mm-thick punch induced loads of 50 N, at a 45° angle to the long axis of the specimens and at a frequency of 8 Hz directly on the posts. To evaluate the bond strengths, the specimens were sectioned perpendicular to the long axis of the teeth, generating 2-mm-thick slices, approximately (5 sections per teeth), which were subjected to the push-out test in a universal testing machine at a 1 mm/min crosshead speed. The push-out bond strength was affected by the mechanical cycling (1-way ANOVA, p = .0001). The results of the control group (7.7 ± 1.3 MPa) were statistically higher than those of G2 (3.9 ± 2.2 MPa) and G3 (3.3 ± 2.3 MPa). It was concluded that the mechanical cycling damaged the bond strength of zirconia posts to root dentin.
Resumo:
The aim of this study was to evaluate the effect of radiotherapy on the radiopacity and flexural strength of composite resin. Forty Z250 composite resin specimens were polymerized using a halogen light-curing unit and divided into 5 groups, in accordance with the radiotherapy dose: G1- without irradiation, G2- 30 Gy, G3- 40 Gy, G4- 50 Gy and GS- 60 Gy Digital images were obtained using a GE 100 X-ray. Radiopacity values were obtained with the Digora digital imaging system and the flexural strength was evaluated with an EMIC universal testing machine. Data were submitted to ANOVA and Tukey 's test. G1 presented the highest radiopacity value, followed by G3, G5, G4 and G2. For flexural strength, G1 presented the lowest value, followed by G2, G5, G3 and G4. Differences were no significant (p>0.05). The commonly used dosage of radiotherapy treatment, did not cause alteration in the radiopacity and flexural strength of resin-based composites.
Resumo:
Objective: To assess the effect of bleaching agents on the microhardness of nanoparticle resin composite. Methods: Twenty-eight cylindrical test specimens (8× 1mm) of Filtek™ Supreme XT resin (3M/ESPE) were prepared and divided into 5 groups. The initial Vickers microhardness was measured (load of 50 grams force for 30 seconds) on the top surface of the test specimens. The groups were treated and divided as follows: G1 - artificial saliva (21 days - control); G2 - 7% hydrogen peroxide gel applied for 4h/day, for 14 days; G3 - 10% carbamide peroxide for 4h/day, for 14 days: G4 - 35% hydrogen peroxide gel applied in three sessions of 30 minutes each, with an interval of one week (21 days) between the sessions; G5 - 35% carbamide peroxide, three sessions of 30 minutes each, with an interval of one week (21 days) between the sessions. The top surfaces of the test specimens received treatment and were submitted to the Vickers microhardness test. Results: The results obtained were submitted to the Analysis of Variance at a fixed criterion, at a level of significance of p=0.05. No significant differences were observed among the treatments tested (p=0.42) when compared with G1. Significant differences (Tukey test) were found when the initial microhardness values were compared with the values after experimental treatments (p<0.01). Conclusion: The application of bleaching agents did not alter the microhardness of resin composites. Therefore, there is no need to change restorations after bleaching.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Creatine kinase (CK) and aspartate aminotransferase (AST) are mainly muscle-specific enzymes, which can be associated with muscle tissue damage. The aim of this study was to assess the activities of CK and AST during the postoperative period, after conventional (G1) and videolaparoscopic ovariectomy (G2), in queens. A further group (G3) was subjected to anaesthesia only. Results demonstrate that there were significant differences between groups. The highest levels of CK were recorded in Gl, however at a confidence level of p < 0.05 there was no significant difference between groups during the first 6 hours after surgery. A significant (p < 0.05) increase of CK values was identified between 0h and 3h in both groups (Gl and G2). Regarding AST activity there was no significant variation between groups, but again there was a significant difference between values at 0h and 3h after surgery. In conclusion, ovariectomy performed by videolap-aroscopy seems to cause less muscle damage when compared to the conventional method. © 2009 by Verlag Hans Huber, Hogrefe AG, Bem.
Resumo:
The purpose of this study was to evaluate the transmittance of seven different composite resins. Ten specimens were prepared (10 mm diameter, 2 mm thickness) for each experimental group, as follows: G1- Charisma® A 2 (Heraeus-Kulzer); G2- Filtek™ Supreme A 2E (3M/ESPE); G3- Filtek™ Supreme A2B (3M/ESPE); G4-Filtek™ Supreme YT (3M/ESPE); G5- Esthet-X® A2 (Dentsply); G6- Esthet-X® YE (Dentsply); G7- Durafill® A 2 (Heraeus-Kulzer) and G8- Filtek™ Z-100 A2 (3M/ESPE). The transmittance mode was measured using a UV-visible spectrophotometer (Cary Instruments) at 400-760 nm. The specimens were evaluated at three different times: zero hour (initial), 24 hours and 10 days after immersion in artificial saliva. The differences in transmittance were determined by two-way analysis of variance (ANOVA) and Tukey's test. The various composite resins showed significant differences in the wavelength dependence of transmittance. The mean values of transmittance increased significantly, with wavelengths increasing from 400 to 760 nm. The performance of the experimental groups was similar in terms of immersion time, considering that at time zero and after 10 days, all the groups showed similar results, which were statistically higher than the values obtained after 24 hours of immersion. The Filtek™ Supreme YT composite resin presented the highest mean transmittance values along the wavelengths at the three measured times. Esthet-X® YE and Durafill® yielded similar mean transmittance values, which were higher than those of the other groups. This study shows that the transmittance values of composite resins are directly related with the type, size and amount of inorganic filler particles.
Resumo:
The aim of this study was to evaluate the effect of desensitizing agents on the micro-shear bond strength of adhesive systems to dentin. Forty bovine teeth were divided into 8 groups (n=5): G1--Single Bond (SB); G2--GH.F + SB; G3-- Desensibilize + SB; G4--essensiv + SB; G5 --ingle Bond 2 (SB2); G6--H.E + SB2; G7--esensibilize + SB2; G8--Dessensiv + SB2. In all of the groups, the desensitizing agents were applied after phosphoric acid etching and before the dentin adhesive application. Z250 composite resin tubes were bonded on the treated surface. After 24 hours, the teeth were tested in a universal machine. Data were submitted to ANOVA and Tukey's test (5%). The results showed that the groups where Desensibilize and Dessensiv were applied exhibited smaller bond strength values.
Resumo:
The study, evaluated the addition of different concentrations of Se in mineral mixture affecting creatine kinase (CK) serum concentrations in cattle. 60 male, Nellore cattle, at about 12 months old, were randomly assigned to groups (15 calves/ group), Gc, G3,6, G5,4 or G6,4 (0, 3.6, 5.4, and 6.4 mg Se/bovine/day). The levels of serum CK in the cattle were not affected by neither the interaction selenium concentration x time nor the concentration of supplementation. However, CK levels increased over the experiment irrespective of dietary selenium concentration. In addition, the frequency of animals with CK levels above normal increased (p<0.10) in group G6,4. The concentrations of selenium studied here do not affect serum CK in cattle, but the daily concentration of 6.4 mg selenium is not recommended because it is possibly toxic effect.
Resumo:
The aim of this study was to evaluate the trans-enamel and trans-dentinal effects of a 35% hydrogen peroxide (H2O2) bleaching gel on odontoblast-like cells. Enamel/dentin discs obtained from bovine incisors were mounted in artificial pulp chambers (APCs). Three groups were formed: G1- 35% H2O2; G2- 35% H2O2 + halogen light application; G3- control. The treatments were repeated 5 times and the APCs were incubated for 12 h. Then, the extract was collected and applied for 24 h on the cells. Cell metabolism, total protein dosage and cell morphology were evaluated. Cell metabolism decreased by 62.09% and 61.83% in G1 and G2, respectively. The depression of cell metabolism was statistically significant when G1 and G2 were compared to G3. Total protein dosage decreased by 93.13% and 91.80% in G1 and G2, respectively. The cells in G1 and G2 exhibited significant morphological alterations after contact with the extracts. Regardless of halogen light application, the extracts caused significantly more intense cytopathic effects compared to the control group. After 5 consecutive applications of a 35% H2O2 bleaching agent, either catalyzed or not by halogen light, products of gel degradation were capable to diffuse through enamel and dentin causing toxic effects to the cells.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Objective: To identify the effect of a self-instructive method (comic strip), applied with distinct approaches and evaluated over two periods, on the oral health of schoolchildren. Method: The sample comprised 2nd year elementary schoolchildren chosen randomly and divided into four groups: a control group (G1) which received no material, a reading group (G2), which was given the comic strip and read it in the classroom, a discussion group (G3), who received the comic strip, which was read out loud in the classroom and discussed, and a complete group (G4), which received the comic strip and which, after reading it, was asked to rewrite the story. O'Leary's plaque index was used as an evaluation instrument, measured immediately prior to application of the program and again 30 days later. The plaque index measured after and 30 days was compared, in each group, using the Wilcoxon test. The plaque index of the diferents groups was compared using the Kruskal-Walis test, in two moments diferents. The significance level was 5%. Results: The results of the evaluation revealed a statistically significant reduction (p<0.05) of the plaque index presented between the two periods in the four groups studied here. However, this reduction was considerably greater in the discussion and complete groups. Conclusion: The use of the self-instruction method associated with work on its content, as occurred in the discussion and complete groups, led to a better understanding of the subject matter, resulting in a higher reduction of plaque indices.
Resumo:
The aim of this study is to evaluate the flexural resistance of three types of restorative materials: compomer (Freedom), resin-modified glass-ionomer (Vitremer) and composite resin (Esthet-X), observing whether the application of bleaching agent can cause alterations of their flexural properties. Sixty samples were made using a 10 x 1 x 1 mm brass mold, and divided into three groups: G1- Freedom (SDI); G2- Vitremer (3M ESPE); G3- Esthet-X (Dentsply). On half of the samples of each group (10 samples) the bleaching treatment was applied and the other half used as control, was stored in distilled water at a temperature of 37 degrees C. Whiteness HP Maxx bleaching system was applied on the sample surface following the manufacturer's recommendations, simulating the bleaching treatment at the clinic. After this period, a flexural strength (three-point bending) test was conducted using (EMIC DL 1000) machine until the samples fractured. The data were submitted to ANOVA and Tukey tests. Of the restorative materials studied, G3-(87.24 +/- 31.40 MPa) presented the highest flexural strength, followed by G1-(61.67 +/- 21.32 MPa) and G2-(61.67 +/- 21.32 MPa). There was a statistical difference in flexural strength after the bleaching treatment. It was concluded that the use of a beaching agent can promote significant alteration of the flexural strength of these restorative materials.
Resumo:
The ELISA technique was used to evaluate and compare young ovine humoral immune response during crotalic antiserum production. Animals were clinically evaluated throughout this process, and the neutralizing capacity of antisera raised against natural (NV) and Cobalt-60 irradiated (IrV) venoms of Crotalus durissus terrificus (C.d.t.) was verified by means of in vitro challenges. Three groups of six animals each were used: G1 received NV; G2 was inoculated with IrV; and G3 was used as control. Animals received six immunizations during 84 days at 14-day intervals. ELISA of antibody profile showed significant difference (p<5%) between experimental groups (G1