256 resultados para Efluentes de estação de tratamento de esgoto


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Civil - FEIS

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study was developed to evaluate the performance of different coagulant and pH dosages by applying the use of Dissolved Air Flotation (FAD) to enable its use in effluent treatment of the extraction process of palm oil. The study was developed in the laboratory, where studies about emulsions stability were made for the production of a synthetic effluent which best suit the characteristics of raw effluent. The synthetic water that would be used in the tests of FAD was produced, once the stability and characterization which best approached the raw wastewater was obtained. Trials tested three coagulant doses, combined with various pH ranges and five upward velocities (Va), finding an optimal range of this combination. Some operating parameters such as time and gradient of rapid mixing (20 s / 1000 s-1), time and gradient flotation (15 min / 60 s-1), chamber pressure saturation (450 kPa) and recirculation rate (20%) were set. In this way, samples were collected for analysis of the removal of turbidity parameters, suspended solids and oils and greases. This one is obtained by a correlation turbidity x oils and greases, referring to the previous analysis. The degree of removal obtained were 73,97% for turbidity, 51,4% for total suspended solids and 86,2% for oils and greases. Removal rates may be increased in later studies, by ranging the velocity gradient and flocculation parameters and the recirculation ratio, and by using lower flotation speeds to these effluent characteristics.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The volume of liquid effluent generated in cattle slaughterhouses is quite high and cannot be released untreated in water bodies due to its high pollution load of predominantly organic origin. To minimize the environmental impacts of its industrial wastewater and meet the local environmental legislation, abattoirs shall make the treatment of these effluents. The present work aims to develop the study of a reactor by sequential batch pilot scale, in order to optimize their performance in treating wastewater from a cattle slaughterhouse. The treatment system used was developed and installed in the Laboratory of Wastewater Treatment, in Faculty of Science and Technology UNESP, Presidente Prudente campus. The procedure used followed the operation of sequential batch reactors, in which all processes and treatment operations occurring sequentially in a single unit, by establishing specific operating cycles, which comprise the following separated phases: aerobic reaction, anoxic reaction, sedimentation and emptying. Aiming to improve the quality of treatment was planned the addition of coagulant Poly Aluminum Chloride (PAC) in the reactor, by determining their optimal dosage by Jar-test trials. Were prepared four steps with specific operating cycles: step one or acclimatization (10 hour of aeration, one hour and 30 minutes of sedimentation and 30 minutes for exchanging the effluent); step 2 (6 hours of aeration or aerobic phase, 4 hours and 45 minutes of stirring or anoxic phase and 1 hour and 15 minutes for sedimentation and exchange effluent); step 3 (2 hours and 30 minutes of aeration, 8 hours and 15 minutes of stirring and 1 hour and 15 minutes for sedimentation and exchange) and step 4 (2 hours of aeration, 8 hours and 45 minutes of stirring and 1 hour and 15 minutes for sedimentation and exchange)... (Complete abstract click electronic access below)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Os riscos à saúde e os altos custos do uso de agrotóxicos e de outras substâncias que favoreçam a produção agrícola têm dado espaço para a Homeopatia atuar como mecanismo alternativo no controle de pragas e incremento na agricultura de sustentabilidade. Diversos trabalhos e experimentos, tradicionais e atuais, enfatizam a importância e a eficácia desta alternativa também à saúde dos humanos e dos animais. O uso de modelos vegetais nos estudos homeopáticos contribui para o entendimento dessa afirmação, pois o efeito placebo passa a não considerado. O objetivo deste trabalho foi verificar os efeitos das soluções homeopáticas derivadas de cristais de ácido giberélico e de ácido salicílico no enraizamento de estacas de hortelã (Mentha spicata L.). Estacas recém-formadas foram mergulhadas em soluções tratamento nas potências 6CH, 12CH, 18CH, 24 CH e 30CH com aplicação única ou suplementar; como testemunhas foram empregadas soluções de etanol 30% não dinamizado, etanol 30% dinamizado e água desmineralizada. Os resultados mostraram que as soluções derivadas do ácido salicílico promoveram melhores resultados que as soluções oriundas do ácido giberélico e dos tratamentos controle. Este aspecto concorda com a prática homeopática como um todo, pois o ácido salicílico é considerado agente inibidor das reações fisiológicas relacionadas com o enraizamento de estacas. Além disso, foi importante detectar que o uso de soluções homeopáticas em regime de dose única trouxe melhores resultados do que o seu uso contínuo

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The mechanical garages do varied types to activities related to the reparation from vehicles such as change from Motor oil, change and cleaning from car pieces, motor rectification, among others. These activities generate different kinds of waste and wastewater that when disposed in an inappropriate way can pollute the environmentand cause risks to the public health. Despite the environmental issues that involves these enterprises, they aren´t object of environmental licensing and there are any rules that regularizes their activities with the goal of these possible environmental impacts mitigation. The environmental diagnosis proposed by the present work has as goal the knowledge of the possible environmental aspects and their effects in the environment, for establishing control measures and from that to generate subsidy for environmental normatization of the sector in the municipal level. Furthermore, it should also define practices as waste production reduction, separation of them at the generator source and convenient final disposal, as well as wastewater production reduction and treatment of them before its launching in the wastewater network. The environmental diagnosis was based on a survey realized in garages from the city of São Carlos – SP, in order to define the more important characteristics of this activity that are related to the environment and public health. From the obtained information from the survey and the interpretation of the data, subsidy for the municipal environment management of the mechanical garages were generated.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Pós-graduação em Microbiologia Agropecuária - FCAV

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

O objetivo do presente trabalho foi avaliar a eficiência do tratamento da manipueira de extração de fécula de mandioca, em separado da água de lavagem das raízes, através de biodigestores anaeróbicos de fluxo ascendente, com separação das fases, sem controle de temperatura ou adição de produtos químicos e, avaliar sua adequabilidade, através de suas características físicas e químicas para lançamento em corpo receptor, sistema público coletor de esgotos ou, aplicação em processod e fertirrigação. Depois dos reatores estabilizados, foram realizados ensaios variando a vazão de alimentação com 8,0; 12,0 e 16,0 L/d, correspondentes a um tempo de retenção hidráulica de 8,17; 5,44 e 4,08 dias, respectivamente. Os melhores resultados para redução da carga orgânica foram obtidos com os tempos de retenção hidráulica (TRH) de 8,17 e 5,44 dias com eficiências médias de 89,8% e 80,9%, respectivamente. As características físicas e químicas dos efluentes tratados foram comparadas com os valores estabelecidos na legislação estadual, federal e, com os parâmetros utilizados pelo orgão ambiental fiscalizador. Os resultados obtidos mostraram que o efluente tratado atende parcialmente aos requisitos legais para o lançamento em corpos receptores, devido ao teor elevado de nitrogênio amoniacal. Por outro lado, foram atendidos integralmente os requisitos legais para o lançamento na rede pública coletora de esgotos. O efluente tratado não atendeu às recomendações requeridas pelo orgão ambiental fiscalizador para a sua disposição através do processo de fertirrigação devido aos teores elevados de ferro (Fe) e de fluoretos (F). Considerando os resultados obtidos, concluímos que, devido à simplicidade do sistema utilizado, com a implantação de melhorias como um pós-tratamento, poderiam ser atingidos os parâmetros que atenderiam integralmente a legislação.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Atualmente a implantação de qualquer planta industrial que possa gerar impacto ambiental, ou até mesmo adequação de equipamentos já instalados para a não geração de poluentes ou geração dentro de limites adequados, passa cada vez mais por fiscalização rigorosa dos órgãos ambientais. A ventilação industrial tem sido e continua sendo a principal medida de controle efetiva para ambientes de trabalho que contenham dispersão de efluentes gasosos e material particulado de natureza prejudiciais, e baseado neste fato de relevância inegável é que se fundamenta este estudo. Um sistema de tratamento de gases com enfoque em ventilação local exaustora engloba vários equipamentos, e dentre eles o filtro de mangas é considerado um dos principais, pois sua função é a de efetuar a filtração dos gases proporcionando emissões dentro das tolerâncias dos órgãos ambientais, refletindo desta forma o objeto principal deste estudo de caso, a eficiência do equipamento. Especificamente neste estudo apresentam-se dados de eficiência do filtro de mangas em questão, componente de um sistema de desempoeiramento de uma caldeira de queima de resíduos sólidos. Foram utilizados dados coletados em campo em dois pontos do circuito do sistema, entrada do filtro de mangas e descarga de gases limpos, além de análise do elemento filtrante. As coletas e análises foram realizadas de acordo com as normas para a correta aferição dos dados gerados. Os resultados permitiram observar patamares de eficiência de filtração para os resíduos gerados na queima, demonstrando os cuidados a serem tomados no dimensionamento do equipamento para esta aplicação.