268 resultados para Contração muscular


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Desenvolvimento Humano e Tecnologias - IBRC

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Among the numerous possibilities of physical exercise, it has been recommended that stretching routines should be incorporated into training programs focused on the elderly population, and that these routines should be preferentially performed on the same strength or aerobic training session. However, studies have shown that muscle strength production can be acutely impaired if it is preceded by static stretching exercises (AE). Although there seems to be a relationship between the number of stretched muscles and strength response, no studies were found examining such relationship in the same study, simultaneously. Thus, the objective of this study is to analyze the acute effect of stretching of different muscle groups on strength performance in older women. Nineteen physically active older women participated in the study (67.8 ± 5.3 years, 68.9 ± 12.4 kg, 157.2 ± 6.4 cm)-usar ponto final em inglês e não vírgula. The participants visited the lab for six consecutive days, three of which were intended to familiarization. Over the next three days, all the participants performed the experimental conditions: control; quadriceps stretching alone and complete stretching, involving the major extensors muscle groups of knees and hips. Both the two stretching conditions were realized with three series of 30s (total volume of 90 seconds for each exercise). All experimental conditions was be performed with an interval of at least 24 hours and order of execution was be randomized. The force transducer was connected to a leg press apparatus, where the isometric force time curve and electromyographic activity of the vastus medial and vastus lateralis were recorded. Measurements were registered immediately after each experimental condition, during five seconds. Statistical analysis comprised descriptive procedures and the One way ANOVA test for repeated measures (p<0.05). No statistically significant differences between the control and the two...

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Several methods are used towards delayed onset muscle soreness appraisal. This study's goal was to investigate, amongst three commonly adopted methods, which one would be the most effective (the one that shows higher values) in the quantification of this phenomenon. 10 male subjects, of age 22.8 ± 3.1 years old, weight 80 ± 12.4 kg, height 174 ± 0.07 cm, without recent experience with strength training (lower limbs) and/or running took place in this study. All subjects carried out a muscle damage induction protocol, which consisted of 30 minute downhill running (-16% or -9.09º) at 80% speed compared to their maximum oxygen consumption. Muscle damage determinants such as isometric peak torque, knee joint range of motion and circumference of the medial portion of the thight were measured before, during, 24, 48, 72 and 96 hours after downhill running. The subjective pain perception was measured simultaneously with the other determinants through three different tests: sitting on and getting up of a chair; climbing and descending from a 45cm step; and self thigh palpation. After going through all subjective pain perception tests, the subjects filled out a visual analog scale with their perception of pain. Muscle damage changes over time were compared through variance analysis (ANOVA) one way for repeated measures. Subjective pain perception values obtained in all three different tests were compared through two way ANOVAs for repeated numbers. The significance level adopted in this study was z ≤ 0.05. The results showed that the step test was the on which better evaluated the delayed onset muscle soreness. No significant differences were found through the ADM and CIR recovery markers. Downhil running determined reduced of PTI (~22.4%). Significant links between pain were obtained for both subjective pain perception tests starting at 24 and 48 hours, where the highest registered average happened in the step test after 48h, with high...

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Biologia Geral e Aplicada - IBB

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To evaluate the volumetric changes due to polymerization and thermocycling on different resin-composites. Methods: Thirteen A2 Universal Dentin shade resin-composites (n = 10) from eight manufacturers were evaluated (4Seasons, Grandio, Venus, Amelogen Plus, P90, Z350, Esthet-X, Amaris, Vita-l-escence, Natural-Look, Charisma, Z250 and Opallis). The polymerization shrinkage percentage (PS) was calculated using an image measurement device (ACUVOL - Bisco Dental). Equal volumes of material, standardized by a semisphere polyurethane matrix (d = 3mm) were used and, after 5 minutes of relaxation, the baseline volume measurements were obtained with 18 J of energy dose from the LED light-curing unit. Measurements were obtained after 5 minutes and PS values calculated. Specimens were stored in a drydark environment for 24 hours and re-measured. Specimens were then thermocycled in distilled water between 5oC and 55oC for 20,000 cycles, subjected to another volume measurement at 5,000 cycle intervals. Specimens were gently dried prior to each measurement. Results: Repeated measurements were made using ANOVA (α = 0.05) showed that all resin-composite volumes were influenced by the number of cycles. Volumes at 5 minutes post-polymerization (12.47 ± 0.08) were significantly lower than those at baseline (12.80 ± 0.09). Volumes at 24 hours (12.43 ± 0.19) were insignificantly lower than those at 5 minutes postpolymerization. With regards to the impact of thermocycling, all specimens showed statistically significant increases in volume after 5,000 cycles (13.04 ± 0.22). Although statistically different from those after 5,000 cycles, there was no statistically significant difference between volumes measured at 10,000 (12.87±0.21), 15,000 (12.92±0.24), and 20,000 (12.84±0.23) cycles. Conclusion: According to the video-imaging analysis, thermocycling caused a significant expansion in resin-composites tested, the volume increase was not able to...

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Ciências da Motricidade - IBRC

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In order to evaluate the hygienic-sanitary conditions of lamb carcasses for human consumption, this study aimed at quantifying populations of indicator microorganisms, such as: mesophiles and psychrotrophs, molds and yeasts, Escherichia coli, Staphylococcus spp. and at identifying pathogenic microorganisms (Salmonella sp. and Listeria spp.). The study was conducted in one lamb slaughterhouse located in the State of São Paulo. Swab samples were collected from muscle surface of forequarter and hindquarter regions of 30 half-carcasses after skinning, evisceration and washing processes. Population counts were between the following values in log10: 2,00 ± 0,32 and 2,59 ± 0,76 UFC/cm2 for mesophiles; 1,52 ± 0,98 and 2,35 ± 1,17 UFC/cm2 for psychrotrophs; 0,75 ± 0,87 and 1,23 ± 0,97 UFC/cm2 for molds and yeasts; 0,00 ± 0,00 and 0,31 ± 0,84 NMP/cm2 for Escherichia coli and 1,75 ± 0,71 and 1,95 ± 0,68 UFC/cm2 for Staphylococcus spp. Salmonella sp. and Listeria spp. were not detected from any of the sampled points. These results indicate the necessity to improve the hygienic-sanitary conditions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)