295 resultados para Cleaning
Resumo:
Pós-graduação em Comunicação - FAAC
Resumo:
Objective: To assess the attitudes and knowledge about hepatitis by scholars and dental practitioners from Recife and its metropolitan region. Method: The research protocol was submitted and approved by the Ethics and Human Research Committee of the Federal University of Pernambuco. There were included 230 undergraduate students in dentistry and 104 dentists who exercise their professional activity in Recife and its Metropolitan Region. They signed a consent form and answered a questionnaire, the evaluative instrument, with objective questions about biosafety, transmission of hepatitis and sexually transmitted diseases. Results: About the types of hepatitis 133 (57.8%) students and 61 (58.7%) professionals claimed to know the types A, B and C. Concerning transmission 31 (13.5%) students and 25 (24.0%) professionals said that the main route of transmission were sexual and bloodstream respectively. Relating to imunization 221 (96.1%) students and 99 (95.2%) professionals reported that have been vaccinated against hepatitis B, however, only 126 (54.8%) students and 55 (52.9%) professionals have followed the immunization’s schema. Regarding the cleaning of the office equipment, 18.7% of the students replied that they do not know who does it. 56.7% of professionals said that it was performed with alcohol 70 ° GL.Conclusions: The findings indicate that there is a concern for biosafety but the knowledge about the forms of hepatitis transmission and biosecurity measures need to be better settled.
Resumo:
Nanotechnology, the science of minuscule, has developed products which are able t o manipulate atoms and molecules that could be applied in the sterilization process of dental instruments. Objetives: The objective of the present study was to evaluate the self-cleaning action of TiO2 and Ag nanoparticles coating on dental instruments by the photocataliys process under UV and visible light irradiation. Material and method: Microbiologic tests were done using dental cement spatulas coated with TiO2 and Ag nanoparticles (one or three layers), and contaminated with 10 mcrl of Pseudomonas aeruginosa and Enterococcus faecalis, respectively. After contamination, they were exposed to ultraviolet light and visible light for 120 minutes. Next, they were transferred to and stored in test tubes with BHI (Brain Heart Infusion) and incubated in 35 to 37 °C. Checking times for bacterial growth and for control and retrieval tests were done at: 24, 48, 72 and 96 hours. Result: The Pseudomonas aeruginosa was inactive after 120 minutes of ultraviolet light irradiation, thus confirming the heterogeneous photocatalytic activity of TiO2 and Ag. The Pseudomonas aeruginosa was not inactivated under visible light irradiation and the Enterococcus faecalis was not inactivated under UV and visible light irradiation of the dental cement spatulas coated with TiO2 and Ag nanoparticles in the readings to 96 hours, showing bacterial growth. Conclusion: There were no influence of one or three layers of TiO2 and Ag nanoparticles coating of the spatulas in the results. The heterogeneous photocatalysis activity of TiO2 and Ag under UV light irradiation was confirmed for Pseudomonas aeruginosa but not under visible light. Enterococcus faecalis did not confirmed the photocatalytics activity of TiO2 and Ag under UV light irradiation and visible lights irradiation.
Resumo:
The aim of this study was to review the literature on the systems used to decontaminate the implant's surface. Different instruments have been proposed, but there is no agreement in the literature about which methods would be more efficient with no damage to the implant surface. It was reported the use of plastic, carbon fiber, stainless-steel and titanium curettes and also the use of other systems such as ultrasonic points with different tips, rubber cups and air abrasion. Literature review: In most of the studies, the injury caused on the titanium surface at the time of instrumentation was examined. In others, the cell adhesion on the titanium dental implants following instrumentation of the implant surface was observed. Moreover, to enhance cleaning around implants, ultrasonic systems were recently tested. Conclusion: Metal instruments can lead to major damage to implant surface, therefore, they are not indicated for decontamination of dental implants surfaces. Furthermore, non-metallic instruments, such as plastic curettes, rubber cups, air abrasion and some ultrasonic systems seem to be better choices to remove calculus and plaque of the sub- and supra-gingival peri-implant area. It is noteworthy that more studies evaluating the effects of these systems are required to establish best practices to be used in the treatment of patients with dental implants.
Resumo:
Introduction: Currently, there are many questions regarding the cleaning methods seeking greater efficiency and less loss of burs. Aim: the aim of this study was to evaluate the influence of cleaning methods on the cutting efficiency and morphological characteristics of stainless steel burs tungsten carbide (carbide). Materials and method: Thirty burs were divided into five groups (n = 5) according with the cleaning method: L1 - steel brush, L2 - nylon brush, L3 - ultrasound + distilled water, L4 - ultrasound + descaling solution and L5 - no cleaning method (control). The burs were used for the cutting of bovine enamel during six periods of 12 minutes each. After each period, the burs were cleaned (except L5 ) following the protocol established for each group. The cutting efficiency was determined by mass loss and morphological characteristics. Result: The average amount of wear after 72 minutes of use were L1 = 0.3558 g; L2 = 0.4275 g; L3 = 0.4652 g; L4 = 0.4396 g e L5 = 0.4854 g; significant differences in the time of use (p < 0.001) and cleaning method (p < 0.001). The L1 group showed the worst performance. Regardless of the experimental group, morphological analysis revealed alterations in the cutting blades soon after the first 12 minutes, being L1 the most affected group. Conclusion: The cleaning with wire brush was the most damaging method to the cutting efficiency and to the morphology of carbide burs.
Resumo:
The main objective of this work was to mount and test an experimental model to measure the hydraulic conductance of ex vivo dentin. Seventeen healthy third molars, with indication of extraction of healthy donors aged between 15 and 30 years were obtained by informed consent. After cleaning them, disinfecting them, including them in resin epoxy and cutting them, there were 17 samples of dentin, corresponding to a disk of resin with a coronal section of tooth showing the dentin exposed on both sides of it. Three machines to measure the hydraulic conductance of the dentin were assembled according to the description of the model of Pashley. Samples were installed in a Chamber of diffusion, connected by using silicone tubes to a graduated transfer pipette and a 20cm water column. Through the displacement of a bubble of water in the inside of the pipette, the hydraulic conductance of each sample was measured 3 times on the 14th, 21st, 28th and 35th day post extraction. The data were tabulated and analyzed statistically. There is no SS difference in the rate of flow of a measured sample in the three machines (p=0.5937). There is no SS difference in measurements of the hydraulic conductance of 13 samples of human dentin measured in days 14, 21, 28 and 35 postextraction (p=0.0704). It is possible to mount an experimental model to study the hydraulic conductance of dentin ex vivo, based on the model of Pashley. The model seems to be reliable, but more research is needed in order to validate its reliability.
Resumo:
Endodontics is a science that embodies etiology, diagnosis, prevention, and treatment of apical periodontitis and its repercussion in the organism. Technological resources in diagnosis and root canal negotiation, and new strategies , associated to mainly cleaning and eliminating the infection of the root canal system, shaping, and filling the endodontic space, according to biological bases, will allow us to reach higher standards of post-treatment success.
Resumo:
Endodontic sealer residues on dentinal surface have negative effects on adhesion of adhesives system and/or can cause discoloration of the dental crown. Objective: To evaluate the efficacy of 95% ethanol in removal of residues of epoxy-based (AH Plus), methacrylate-based (Epiphany SE) or calcium-based (Sealapex) sealers on dentinal surface. Material and methods: Thirty-two bovine incisor dental crown fragments (0.5 mm x 0.5 mm) were treated with 17% EDTA and 2.5% NaOCl. The specimens were divided into three experimental groups (n = 10): G1 (AH Plus), G2 (Epiphany SE) and G3 (Sealapex). In each group was applied a coating of one endodontic sealer type and were left undisturbed for 5 minutes. After this period, the specimens were cleaned with 95% ethanol. The control group was composed by two specimens that did not receive any sealer or cleaning treatment. The sealer residues persistence after cleaning with 95% ethanol was evaluated by scanning electron microscopy (x500) and a score system was applied. Data obtained were analyzed by Kruskal-Wallis and Dunn tests (α = 5%). Results: Moderate amount of endodontic sealer residues were observed in all groups, regardless of the endodontic sealer compositions. G1, G2 and G3 presented similar amount of sealer residues on dentinal surface after cleaning with 95% ethanol (p > 0.05). Conclusion: 95% ethanol was inefficiency to remove completely AH Plus, Epiphany SE and Sealapex residues of sealer-contaminated dentin.
Resumo:
The irrigation of root canals aims to their cleaning and disinfection, improving endodontic treatment success. OBJECTIVE: To investigate the influence of the diameter and type of irrigation needle and the root canal enlargement on the mechanical efficacy of endodontic irrigation. MATERIAL AND METHODS: Twelve human single-rooted mandibular incisors were used. During some instrumentation stages (enlargement by #20, #30, and #40 K file), root canals were filled with radiographic contrast solution mixed to propyleneglycol and zinc oxide. Needles with different diameters and designs were employed: G1 – 23G and lateral opening; G2 – 22G and apical opening; G3 – 30G and lateral opening; G4 – 30G and apical opening. The needles were inserted up to resistance, with 1 mm step-back to avoid root canal obliteration. The irrigation was performed with 2 mL of distilled water. Before and after irrigation/aspiration, teeth were radiographed at bucco-lingual and mesiodistal direction, using a digital radiographic system. Then, root canal areas, before (filled by contrast solution) and after irrigation (remnant of contrast solution), were submitted to image subtraction with Adobe Photoshop CS4 software. Subsequently, the areas were measured by Image Tool 3.0 software, allowing the obtaining of the cleaning percentage for each modality. Data were analysed by using Anova and Tukey's test. The level of significance was set at P < 0.05. RESULTS: For all root canal enlargements, 30G needles (G3 e G4) presented a better cleaning efficacy. In all groups, higher cleaning efficacy percentage was observed at #30 and #40 K file enlargement. CONCLUSION: Regardless their design, thinner needles were more effective; a better cleaning efficacy occurred in more enlarged root canals.
Resumo:
Introduction: The irrigation of root canals aims to their cleaning and disinfection, improving endodontic treatment success. Objective: To investigate the influence of the diameter and type of irrigation needle and the root canal enlargement on the mechanical efficacy of endodontic irrigation. Material and methods: Twelve human single-rooted mandibular incisors were used. During some instrumentation stages (enlargement by #20, #30, and #40 K file), root canals were filled with radiographic contrast solution mixed to propyleneglycol and zinc oxide. Needles with different diameters and designs were employed: G1 – 23G and lateral opening; G2 – 22G and apical opening; G3 – 30G and lateral opening; G4 – 30G and apical opening. The needles were inserted up to resistance, with 1 mm step-back to avoid root canal obliteration. The irrigation was performed with 2 mL of distilled water. Before and after irrigation/aspiration, teeth were radiographed at bucco-lingual and mesiodistal direction, using a digital radiographic system. Then, root canal areas, before (filled by contrast solution) and after irrigation (remnant of contrast solution), were submitted to image subtraction with Adobe Photoshop CS4 software. Subsequently, the areas were measured by Image Tool 3.0 software, allowing the obtaining of the cleaning percentage for each modality. Data were analysed by using Anova and Tukey’s test. The level of significance was set at P < 0.05. Results: For all root canal enlargements, 30G needles (G3 e G4) presented a better cleaning efficacy. In all groups, higher cleaning efficacy percentage was observed at #30 and #40 K file enlargement. Conclusion: Regardless their design, thinner needles were more effective; a better cleaning efficacy occurred in more enlarged root canals.
Resumo:
Introduction: Endodontic sealer residues on dentinal surface have negative effects on adhesion of adhesives system and/or can cause discoloration of the dental crown. Objective: To evaluate the efficacy of 95% ethanol in removal of residues of epoxy-based (AH Plus), methacrylate-based (Epiphany SE) or calcium-based (Sealapex) sealers on dentinal surface. Material and methods: Thirty-two bovine incisor dental crown fragments (0.5 mm x 0.5 mm) were treated with 17% EDTA and 2.5% NaOCl. The specimens were divided into three experimental groups (n = 10): G1 (AH Plus), G2 (Epiphany SE) and G3 (Sealapex). In each group was applied a coating of one endodontic sealer type and were left undisturbed for 5 minutes. After this period, the specimens were cleaned with 95% ethanol. The control group was composed by two specimens that did not receive any sealer or cleaning treatment. The sealer residues persistence after cleaning with 95% ethanol was evaluated by scanning electron microscopy (x500) and a score system was applied. Data obtained were analyzed by Kruskal-Wallis and Dunn tests (α = 5%). Results: Moderate amount of endodontic sealer residues were observed in all groups, regardless of the endodontic sealer compositions. G1, G2 and G3 presented similar amount of sealer residues on dentinal surface after cleaning with 95% ethanol (p > 0.05). Conclusion: 95% ethanol was inefficiency to remove completely AH Plus, Epiphany SE and Sealapex residues of sealercontaminated dentin.
Resumo:
Introduction The aim of this study was to compare the effect of QMix, BioPure MTAD, 17 % EDTA, and saline on the penetrability of a resin-based sealer into dentinal tubules using a confocal laser scanning microscope (CLSM) and to describe the cleaning of root canal walls by SEM. Methods Eighty distobuccal roots from upper molars were selected and randomly divided into four groups (n=20) before root canal preparation according to the solution used in the final rinse protocol (FRP): QG (QMix), MG (BioPure MTAD), EG (17 % EDTA), and CG (control group: saline). Ten roots of each group were prepared for SEM, and images (×2000) from the canal walls were acquired. The remaining canals were filled with a single gutta-percha cone and AH Plus with 0.1 % Rhodamine B. The specimens were horizontally sectioned at 4 mm from the apex, and the slices were analyzed in CLSM (×10). Sealer penetration was analyzed with Adobe Photoshop software. Results QG and EG presented similar amounts of sealer penetration (P>.05). MG and CG presented the lowest penetrability values (P<.05). The best results for smear layer removal of the apical third of the root canal were achieved by the QG and EG groups when compared with MG and CG (P<.05). Conclusions Seventeen percent EDTA and QMix promoted sealer penetration superior to that achieved by BioPure MTAD and saline. Clinical relevance Despite studies have not confirmed the relationship between sealing ability of endodontic sealers and their penetration in dentinal tubules, sealer penetration assumes importance, since endodontic sealers, unlike guttapercha, are able to penetrate in dentinal tubules, isthmus, and accessory canals, filling the root canal system.
Resumo:
Introduction: Despite tooth avulsion following trauma being relatively common in children, the available studies show that adults have limited knowledge about it. Aim: The purpose of this study was to assess, by a questionnaire, the mothers’ general knowledge about the immediate management of tooth avulsion. Material and method: This descriptive study was carried out on a convenient sample of mothers (n= 65) who participated of the “Pastoral da Criança”, from Araraquara, SP, Brazil. The questionnaire comprised 15 questions about personal data and knowledge on tooth avulsion management. Results: Participants were, on average, 35 years old. A total of 30.8% of the mothers reported that their children suffered dental trauma. The majority had never received advice on this subject (76.9%); and did not know how teeth are kept in the dental arch (69.2%). Almost a half of the sample believed that an avulsed tooth can be replanted (49.2%). In relation to the management of tooth avulsion, 40% of them would clean the avulsed tooth with water, even if it was not dirty (38.5%). Most of them (69.2%) would take the tooth by hand for cleaning purposes, regardless the tooth region; and believed that brushing the tooth was important to take the dirty out (67.7%). Conclusion: The general knowledge of mothers about the immediate management of tooth avulsion was considered inadequate endangering the successful treatment of tooth avulsion.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Pós-graduação em Engenharia Mecânica - FEB