256 resultados para Bone implants
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The correction of bone defects can be performed using autogenous or alloplastic materials, such as beta-tricalcium phosphate (β-TCP). This study compared the changes in bone volume (CBV) after maxillary sinus lifting using autogenous bone (n=12), autogenous bone associated with β-TCP 1:1 (ChronOS; DePuy Synthes, Paoli, CA, USA) (n=9), and β-TCP alone (n=11) as grafting material, by means of cone beam computed tomography (CBCT). CBV was evaluated by comparing CBCT scans obtained in the immediate postoperative period (5-7 days) and at 6 months postoperative in each group using OsiriX software (OsiriX Foundation, Geneva, Switzerland). The results showed an average resorption of 45.7±18.6% for the autogenous bone group, 43.8±18.4% for the autogenous bone+β-TCP group, and 38.3±16.6% for the β-TCP group. All bone substitute materials tested in this study presented satisfactory results for maxillary sinus lifting procedures regarding the maintenance of graft volume during the healing phase before the insertion of implants, as assessed by means of CBCT.
Resumo:
The aim of this study was to evaluate the survival of single dental implants subjected to immediate function. Twelve patients with edentulous areas in the posterior mandible were included in the study. All received at least one regular platform dental implant (3.75mm×11mm or 3.75mm×13mm). Clinical and radiographic parameters were evaluated. The survival rate after 12 months was 83.3%. The implants showed no clinical mobility, had implant stability quotient values (ISQ; Osstell) around 70, bone loss of up to 2mm, and a probing depth of ≤3mm. Although the posterior mandible is an area in which the immediate loading of dental implants should be performed with caution, this treatment presented a good success rate in the present study sample.
Resumo:
To compare peri-implant soft- and hard-tissue integration at implants installed juxta- or sub-crestally. Furthermore, differences in the hard and soft peri-implant tissue dimensions at sites prepared with drills or sonic instruments were to be evaluated. Three months after tooth extraction in six dogs, recipient sites were prepared in both sides of the mandible using conventional drills or a sonic device (Sonosurgery(®) ). Two implants with a 1.7-mm high-polished neck were installed, one with the rough/smooth surface interface placed at the level of the buccal bony crest (control) and the second placed 1.3 mm deeper (test). After 8 weeks of non-submerged healing, biopsies were harvested and ground sections prepared for histological evaluation. The buccal distances between the abutment/fixture junction (AF) and the most coronal level of osseointegration (B) were 1.6 ± 0.6 and 2.4 ± 0.4 mm; between AF and the top of the bony crest (C), they were 1.4 ± 0.4 and 2.2 ± 0.2 mm at the test and control sites, respectively. The top of the peri-implant mucosa (PM) was located more coronally at the test (1.2 ± 0.6 mm) compared to the control sites (0.6 ± 0.5 mm). However, when the original position of the bony crest was taken into account, a higher bone loss and a more apical position of the peri-implant mucosa resulted at the test sites. The placement of implants into a sub-crestal location resulted in a higher vertical buccal bone resorption and a more apical position of the peri-implant mucosa in relation to the level of the bony crest at implant installation. Moreover, peri-implant hard-tissue dimensions were similar at sites prepared with either drills or Sonosurgery(®) .
Resumo:
To evaluate the peri-implant soft and hard tissue adaptation at implants with different modified surfaces and configurations. Six Beagle dogs were used. Mandibular premolars and first molars were extracted bilaterally. After 3 months, full-thickness flaps were elevated, and two different types of trans-mucosal implants (ICX-Gold®, Medentis Medical GmbH, Dernau, Germany and SLActive®, Institute Straumann, Bern, Switzerland) and two different surfaces were randomly installed in the distal regions of one side of the mandible. Abutments were applied, and a nonsubmerged healing was allowed. After 1 month, the procedures were performed in the other side of the mandible, and after a further month, the animals were sacrificed, biopsies were collected, and ground sections prepared for histological examination. Similar results in marginal bone and soft tissues dimensions were observed after 1 month of healing at the two implant systems used, and no major changes could be observed after 2 months of healing. After 1 month, the percentage of new bone was 69.0% and 68.8% at ICX-Gold and SLActive surfaces, respectively. After 2 months, the percentage of new bone was 67.8% and 71.9% at ICX-Gold Medentis and SLActive surfaces, respectively. No statistically significant differences in osseointegration were found. The two implant systems used resulted in similar osseointegration after 1 and 2 months of healing.
Resumo:
To discuss important characteristics of the use of dental implants in posterior quadrants and the rehabilitation planning. An electronic search of English articles was conducted on MEDLINE (PubMed) from 1990 up to the period of March 2014. The key terms were dental implants and posterior jaws, dental implants/treatment planning and posterior maxilla, and dental implants/treatment planning and posterior mandible. No exclusion criteria were used for the initial search. Clinical trials, randomized and non randomized studies, classical and comparative studies, multicenter studies, in vitro and in vivo studies, case reports, longitudinal studies and reviews of the literature were included in this review. One hundred and fifty-two articles met the inclusion criteria of treatment planning of dental implants in posterior jaw and were read in their entirety. The selected articles were categorized with respect to their context on space for restoration, anatomic considerations (bone quantity and density), radiographic techniques, implant selection (number, position, diameter and surface), tilted and pterygoid implants, short implants, occlusal considerations, and success rates of implants placed in the posterior region. The results derived from the review process were described under several different topic headings to give readers a clear overview of the literature. In general, it was observed that the use of dental implants in posterior region requires a careful treatment plan. It is important that the practitioner has knowledge about the theme to evaluate the treatment parameters. The use of implants to restore the posterior arch presents many challenges and requires a detailed treatment planning.
Resumo:
For oral rehabilitation with implant-supported prostheses, there are required procedures to create the bone volume needed for installation of the implants. Thus, bone grafts from intraoral or extraoral donor sites represent a very favorable opportunity. This study aimed to review the literature on the subject, seeking to discuss parameters for the indications, advantages and complications of techniques for autogenous bone grafts.
Resumo:
This work aimed to analyze clinically and histologically the allogen bone graft behavior at 6 and 9 months. A leukoderm, female, 55 years old patient sought dental care for oral rehabilitation with dental implants and implant supported fixed prosthesis in the maxilla. Bilateral sinus lifting procedure were performed in a same patient, the analysis were made after 6 and 9 months, respectively. At 6 months, there was lack of a better bone remodeling in the region, associated to the presence of fibrous connective tissue within the collected tissue, showing us that this is not the best stage of tissue maturation to place dental implants. The 9 months period showed an improvement, with a more organized bone tissue surrounding particles of homogenous bone, what possibly had increased implant stability at the time of surgery. There is no doubt about the increase of clinical applications of FFBA, but there are no studies available regarding the standardization of time to load implants inserted in allografts. So papers with long-term monitoring are necessary to eliminate questions that still remain to be answered.
Resumo:
Although the search for the ideal bone substitute has been the focus of a large number of studies, autogenous bone is still the gold standard for the filling of defects caused by pathologies and traumas, and mainly, for alveolar ridge reconstruction, allowing the titanium implants installation. OBJECTIVES: The aim of this study was to evaluate the dynamics of autogenous bone graft incorporation process to surgically created defects in rat calvaria, using epifluorescence microscopy. MATERIAL AND METHODS: Five adult male rats weighing 200-300 g were used. The animals received two 5-mm-diameter bone defects bilaterally in each parietal bone with a trephine bur under general anesthesia. Two groups of defects were formed: a control group (n=5), in which the defects were filled with blood clot, and a graft group (n=5), in which the defects were filled with autogenous bone block, removed from the contralateral defect. The fluorochromes calcein and alizarin were applied at the 7th and 30th postoperative days, respectively. The animals were killed at 35 days. RESULTS: The mineralization process was more intense in the graft group (32.09%) and occurred mainly between 7 and 30 days, the period labeled by calcein (24.66%). CONCLUSIONS: The fluorochromes showed to be appropriate to label mineralization areas. The interfacial areas between fluorochrome labels are important sources of information about the bone regeneration dynamics.
Resumo:
The purpose of this study was to evaluate the repair process in the reconstruction of the anterior wall of the frontal sinus of monkeys with bovine bone matrix. Four adult Cebus apella monkeys underwent an ostectomy of the anterior wall of the frontal sinus. The frontal sinus mucosa and the nasofrontal duct were not manipulated. Reconstruction occurred with implants of bovine bone matrix laminae measuring 2.0 x 2.5 cm and 0.4 mm thick, stabilized under pressure in the lateral wall of the frontal sinus. The monkeys were sacrificed over a period of 150 days and routine laboratory procedures were followed for hematoxylin-eosin staining and histologic evaluation of the specimens. Neoformed bone tissue was observed in contact with the frontal sinus mucosa and the bovine bone matrix. The frontal sinus mucosa remained whole without fibrous tissue or cystic formations. There was no occurrence of cellularization as well as revascularization of the bovine bone matrix, though it has permitted bone conduction on this surface. It was possible to conclude that the demineralized bovine bone matrix was biotolerable, being incorporated into the bone without the presence of inflammatory cells with characteristics of inertness and antigenicity and behaved as an osteoconductive material.
Resumo:
Background. Although the long-term success of implant treatment has been well- established, failures can still occur and the smoking habit has been reported as a risk factor for implant loss. A literature review on the effects of smoking on the survival of dental implants was undertaken. Methods and Results. Medline database was used to carry out the review with the keywords “osseointegration”, “smoking” and “bone healing”. The cigarette has more than 4,000 bioactive chemical components with potential toxic effects to human tissues including bone. Nicotine is the main component of the cigarette and it is frequently associated with bone healing failures. Since smoking negatively affects the osseointegration of dental implants, the main target is to quit the consumption of cigarettes. Conclusion. Nevertheless, the smoking habit should not be an absolute contraindication for implant treatment, but, patients should be advised that they are at a greater risk of implant failure.
Resumo:
Purpose: The aim of this study was to assess the contributions of some prosthetic parameters such as crown-to-implant (C/I) ratio, retention system, restorative material, and occlusal loading on stress concentrations within a single posterior crown supported by a short implant. Materials and Methods: Computer-aided design software was used to create 32 finite element models of an atrophic posterior partially edentulous mandible with a single external-hexagon implant (5 mm wide × 7 mm long) in the first molar region. Finite element analysis software with a convergence analysis of 5% to mesh refinement was used to evaluate the effects of C/I ratio (1:1; 1.5:1; 2:1, or 2.5:1), prosthetic retention system (cemented or screwed), and restorative material (metal-ceramic or all ceramic). The crowns were loaded with simulated normal or traumatic occlusal forces. The maximum principal stress (σmax) for cortical and cancellous bone and von Mises stress (σvM) for the implant and abutment screw were computed and analyzed. The percent contribution of each variable to the stress concentration was calculated from the sum of squares analysis. Results: Traumatic occlusion and a high C/I ratio increased stress concentrations. The C/I ratio was responsible for 11.45% of the total stress in the cortical bone, whereas occlusal loading contributed 70.92% to the total stress in the implant. The retention system contributed 0.91% of the total stress in the cortical bone. The restorative material was responsible for only 0.09% of the total stress in the cancellous bone. Conclusion: Occlusal loading was the most important stress concentration factor in the finite element model of a single posterior crown supported by a short implant.
Resumo:
PURPOSE: In view of reports in the literature on the benefits achieved with the use of platform switching, described as the use of an implant with a larger diameter than the abutment diameter, the goal being to prevent the (previously) normal bone loss down to the first thread that occurs around most implants, thus enhancing soft tissue aesthetics and stability and the need for implant inclination due to bone anatomy in some cases, the aim of this study was to evaluate bone stress distribution on peri-implant bone, by using three-dimensional finite element analysis to simulate the influence of implants with different abutment angulations (0 and 15 degrees) in platform switching. METHODS: Four mathematical models of an implant-supported central incisor were created with varying abutment angulations: straight abutment (S1 and S2) and angulated abutment at 15 degrees (A1 and A2), submitted to 2 loading conditions (100 N): S1 and A1-oblique loading (45 degrees) and S2 and A2-axial loading, parallel to the long axis of the implant. Maximum (σmax) and minimum (σmin) principal stress values were obtained for cortical and trabecular bone. RESULTS: Models S1 and A1 showed higher σmax in cortical and trabecular bone when compared with S2 and A2. The highest σmax values (in MPa) in the cortical bone were found in S1 (28.5), followed by A1 (25.7), S2 (11.6), and A2 (5.15). For the trabecular bone, the highest σmax values were found in S1 (7.53), followed by A1 (2.87), S2 (2.85), and A2 (1.47). CONCLUSIONS: Implants with straight abutments generated the highest stress values in bone. In addition, this effect was potentiated when the load was applied obliquely.
Resumo:
Objective In the last decades aroused the interest for bone tissue bank as an alternative to autogenous grafting, avoiding donor sites morbidity, surgical time, and costs reduction. The purpose of the study was to compare allografts (ALg) with autografts (AUg) using histology, immunochemistry, and tomographic analysis. Material and methods Fifty-six New Zealand White rabbits were submitted to surgical procedures. Twenty animals were donors and 36 were actually submitted to onlay grafting with ALg (experimental group) and AUg (control group) randomly placed bilaterally in the mandible. Six animals of each group were sacrificed at 3, 5, 7, 10, 20, and 60 postoperative days. Immunolabeling was accomplished with osteoprotegerin (OPG); receptor activator of nuclear factor-k ligand (RANKL); alkaline phosphatase (ALP); osteopontin (OPN); vascular endothelial growth factor (VEGF); tartrate-resistant acid phosphatase (TRAP); collagen type I (COL I); and osteocalcin (OC). Density and volume of the grafts was evaluated on tomography obtained at the surgery and sacrifice. Results The ALg and AUg exhibited similar patterns of density and volume throughout the experiments. The intra-group data showed statistical differences at days 7 and 60 in comparison with other time points (P = 0.001), in both groups. A slight graft expansion from fixation until day 20 (P = 0.532) was observed in the AUg group and then resorbed significantly at the day 60 (P = 0.015). ALg volume remained stable until day 7 and decreased at day 10 (P = 0.045). The light microscopy analysis showed more efficient incorporation of AUg onto the recipient bed if compared with the ALg group. The immunohistochemical labeling picked: at days 10 and 20 with OPG in the AUg group and at day 7 with TRAP in the ALg group (P = 0.001 and P = 0.002, respectively). Conclusions ALg and AUg were not differing in patterns of volume and density during entire experiment. Histological data exhibit more efficient AUg incorporation into recipient bed compared with the ALg group. Immunohistochemistry outcomes demonstrated similar pattern for both ALg and AUg groups, except for an increasing resorption activity in the ALg group mediated by TRAP and in the AUg group by higher OPG labeling. However, this latter observation does not seem to influence clinical outcomes.
Resumo:
Dentoalveolar traumatisms, particularly those that affect the anterior teeth, interfere adversely in the patient s life.Among them, tooth avulsion is pointed out because it is characterized as a complex injury that affects multiple tissues, andbecause there is no effective treatment available for its resolution with a stable long-term outcome.Aim/Hypothesis: The aim of the present study was to relate a clinical case of complete reconstruction of atrophy of the alveolarbone corresponding to tooth 11, lost by tooth resorption 10 years after the tooth reimplantation procedure.Material and methods: Reconstruction was performed with autogenous bone harvested from the mentum donor site. Surgicalaccess began in the receptor area with a Newman mucoperiosteal incision using a scalpel blade 15 mounted in a scalpel handlefor detachment and exposure of the receptor site. Extensive bone resorption was observed in the vestibular-palatine direction,proved by the thinness of the receptor bed. Decorticalization of the vestibular bone plate was performed. After preparing thereceptor bed, and incision was made in the mucosa in the depth of the anterior vestibular fornix, then a perpendicular muscleperiostealincision to detach and exposure the donor area. The bone graft necessary for reconstruction of the donor area wasdelimited, followed by monocortical osteotomy and the monocortical graft was removed. The next stage was to perform shapingfor passive graft accommodation and fixation by means of two bicortical screws. After fixation of the graft the sharp angles wererounded off in order to avoid possible exposure and/or fenestrations of the reconstructed area, then the receptor and donor areawere sutured. After the 6-month period to allow incorporation of the autogenous graft, an osseointegrated dental implant wasinserted. At the end of the 6-month period of waiting for osseointegration to occur, the process of fabricating the screw-retainedmetal ceramic