237 resultados para simulating
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
This study tested the fluoride-release rate and the root caries inhibitory effect of dental adhesives. In phase 1, the fluoride released from samples (n = 5) of the adhesives A (Optibond Solo), B (One-up Bond F), C (Prime & Bond NT), D (Tenure Quick), and also of the controls [+] (glass-ionomer cement) and [-] (non-fluoride releasing adhesive), was quantified on a daily basis during a pH-cycling, caries-simulating phenomenon. In phase 2, restorations were made in bovine root dentine slabs (n = 16) with the same adhesives associated with a non-fluoridated composite. Control [+] restorations were made entirely with glass-ionomer cement. Specimens were thermocycled and submitted to the pH-cycling regimen. Demineralization areas and the presence of the wall lesion (WL) and the inhibition zone (IZ) were determined by polarizing light microscopy in dentine adjacent to the restoration. The highest concentration of fluoride was released by the control [+]; adhesives A, B and C, also released fluoride. No detectable amount of fluoride was released by D or [-]. Smaller areas of demineralization were found with control [+], whereas the demineralization areas of adhesives A-D and [-] did not differ from each other. No WL was detected, and higher percentages of IZ were recorded to [+] and to adhesive A. Although some dental adhesives were able to release fluoride, they could not inhibit secondary caries development as well as the glass-ionomer cement.
Resumo:
Since the use of bovine instead of human dentine to evaluate cariogenic and anticariogenic substances is not well established, this in situ study was conducted. Eleven volunteers wore palatal acrylic devices containing 4 dentine slabs (2 human and 2 bovine). Sucrose solution (20%) was dripped over all slabs 4 times a day, simulating a cariogenic challenge. Dentifrice slurries, fluoridated or not, were dripped over specified dentine slabs 3 times a day to evaluate caries reduction. After 14 days, the biofilm formed on the dentine slabs was collected for microbiological analysis. In dentine, mineral loss (DeltaZ) and lesion depth (LD) were determined by cross-sectional microhardness and by polarized light microscopy, respectively. The total streptococci and mutans streptococci counts in the biofilm formed either on human or on bovine slabs, whether treated or not with fluoride dentifrice, were not statistically different. The DeltaZ and the LID values of dentine treated with fluoride dentifrice were significantly lower than the values of dentine treated with non-fluoride dentifrice. The differences in the DeltaZ and LD values between the human and bovine dentine were not statistically significant. The results suggest that bovine dentine can be used instead of human to evaluate caries development and inhibition. Copyright (C) 2003 S. Karger AG, Basel.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
In the seed production system, genetic purity is one of the fundamental requirements for its commercialization. The present work had the goal of determined the sample size for genetic purity evaluation, in order to protect the seed consumer and the producer and to evaluate the sensitivity of microsatellite technique for discriminating hybrids from their respective relatives and for detecting mixtures when they are present in small amounts in the samples. For the sequential sampling, hybrid seeds were marked and mixed in with the seed lots, simulating the following levels of contamination: 0.25, 0.5, 1.0, 2.0, 4.0, and 6.0%. After this, groups of 40 seeds were taken in sequence, up to a maximum of 400 seeds, with the objective of determining the quantity of seeds necessary to detect the percentage of mixture mentioned above. The sensitivity of microsatellite technique was evaluated by mixing different proportions of DNA from the hybrids with their respective seed lines. For the level of mixture was higher than 1:8 (1P1:8P2; 8P1:1P2), the sensitivity of the marker in detecting different proportions of the mixture varied according to the primer used. In terms of the sequential sampling, it was verified that in order to detect mixture levels higher than 1% within the seed lot- with a risk level for both the producer and the consumer of 0.05- the size of the necessary sample was smaller than the size needed for the fixed sample size. This also made it possible to reduce costs, making it possible to use microsatellites to certify the genetic purity of corn seeds lots.
Resumo:
The Rio Claro Formation, Tertiary-Quaternary age, is composed of unconsolidated sediments deposited by fluvial systems. In Paulínia (SP) region geological studies comprising sedimentological, structural and geomorphological aspects indicate that the Rio Claro Formation is constituted by deposits of a meandering fluvial system. Data from SPT drillings were used to obtain sedimentary textural information in order to generate stochastic stratigraphic models. Particle size analysis was carried with the core samples which resulted in the distinction of five litofacies, three of which can be grouped into only one mudstone unit. The other two facies represent channel belt facies, being clayey sands and medium to coarse sands. Geostatistical modeling of the stratigraphic architecture followed together with correlation of analogue outcrop data and conceptual models for this type of depositional system. 100 models were generated with the SPT drillings and 50 models were generated with data from an analogue outcrop, which allowed constraining of both simulation sets to the depositional model given for the region. T-PROGS methodology has good applicability in simulating stratigraphic frameworks and its inherent limitations may be approached with parallel studies, such as stochastic modeling of analogue outcrops or geophysical methods
Resumo:
This work is initially based in give a solution to a problem consisting of lifting a load in a warehouse focusing specifically on the solution´s project and comparison of the results obtained following the sequence of the book and comparing these results with the finite elements simulation based on the 3D components modeling. Starting from that was realized the project of the worm gear reducer to solve the problem and makes the work easier. The project consisted basically of the study, project itself and simulation by software of a worm gear reducer and projects steps, starting with the initial problem conditions (to lifting a load up to an specific height at a given time) following all the reducer project sequence, starting by the preliminary draft and electric motor selection using iterative process, material selection, worm gear dimensioning, axles, keyways, bearings and coupling. After that was performed the three dimensional modeling of the components using SolidWorks software and simulating these components using Ansys software. The results show the importance of the CAD in terms of improving project development speed and reducing costs with prototypes
Resumo:
Human development and population growth during the twentieth century increased the water demand, tripling its consumption between 1950 and 1990. As the water streams were polluted; and as water is the source of minerals and also regulates vital functions, it becomes the vehicle of transmission and consequently spreads many diseases. Probably, the industries are the major responsible for this pollution when they dump untreated effluents to water streams, saturating the already insufficient net of sanitation facilities polluting water and soil. An effective treatment has been established with low cost in Europe and the United States, through constructed systems on wetlands Constructed Wetland Systems - CWSs, gradually used in other countries in the last three decades. Lately, we observe a continuous growth in Brazilian poultry business, and poultry industry showed greatest dynamism in the country, following the global market. Pondering this information and the efficiency of such treatment, this work aimed to study prototypes, in a laboratory scale, simulating ascending and descending types of CWSs, vegetated with aquatic macrophytes Eichhornia crassipes and the uses of aggregates and soil, to treat industrial wastewater from slaughterhouses and aviary. We conducted the initial characterization of the effluent to have an idea of its constituents and to scale the system and the continuous flow. Furthermore, we characterized the soil to be used in this system. The collects are periodically made in the refrigeration industry FRICOCK FRIGORIFICAÇÃO AVICULTURA INDÚSTRIA E COMÉRCIO LTDA. for local treatment simulation. The effluent that was treated with 12 prototypes of CWSs are analyzed with some frequency. The results of these reviews were compared to the effluent coming from the industry... (Complete abstract click electronic access below)
Resumo:
The study of mathematical modeling assists in evaluation of the capacity of production and measurement of generation time of biogas in landfills, enabling the implantation of projects of energy generation from methane. Thus, the work aims, by simulating scenarios of potential methane generation in the landfill in Rio Claro, the use of field data from methane flow and waste grounded parameters as references for selecting values of k e L0 used to estimate methane generation model in LandGEM. As a result it was found that compared the characteristics adopted in the four scenarios recommended by the USEPA literature with those found in the landfill of Rio Claro (high amount of organic matter in the waste landed and daily practice of leachate recirculation), the scenario that apparently better represent the rate of methane generation is the scenario 01, with k = 0.7 and L0 = 96. Now, the adjustment of parameters in relation to the data field of methane flow, the value of L0 which best fits the methane generation from the landfill in Rio Claro is 150, while for k the line behavior that best represents the reality are values between 0.7 and 0.3. Regarding the parameters of the waste grounded, between the suggested values of k, 0,3 is most consistent with the intermediate level of biological degradation of the residue grounded, while L0 due to the biodegradability of the waste, a new value between 120 and 150 may be more appropriate for the study
Resumo:
Due to greater productivity in the auto industry and the high competition in the current market, employees are required to perform repeated movements and often, with short intervals of rest. This daily exposure causes muscle tension and overloads occasional, thus creating problems and psychosocial stress. Currently companies are concerned with the welfare of the employee, where the main focus is product quality and life of the worker, thus justifying such a study. Therefore , this technical work to assist the master's thesis of graduate student Daniel Rodriguez , was developed with the objective is to analyze , develop, design and construct a coupled to a load cell device simulating a stitcher to be used in an industry the posts stapling upholstery of seats . Are the stages of design and construction detailed in this work and its positive results in relation to the technical part of the study
Resumo:
The biomagnetic techniques use different magnetic field detectors to measure parameters of the human physiology. Those techniques present the advantage of being noninvasive and radiation free. Among them we can show up the Superconducting Quantum Interference Device (SQUID), the Current Alternate Biosusceptometry (ACB) and, more recently, the employment of anisotropic magnetoresistive sensors. Those magnetic sensors have a low cost and good sensitivity to measure different physiological parameters using magnetic markers. The biomagnetic techniques have being used successfully through study on the characteristics of the gastrointestinal tract. Recent research, the magnetoresistors were used to evaluate the transit time and localization of magnetic sources in different parts of the gastrointestinal tract. The objective of this work is the characterization, with in vitro tests, of a biomagnetic instrumentation using two 3-axis magnetoresistors arranged in a gradiometric coplanar setup to evaluate esophageal transit time, analyze and compare the results of experimental signals and the magnetic theory, as well as evaluate the instrumentation gain with use of tri-axial sensor front to the mono-axial sensor. The instrumentation is composed by two three-axis sensing magnetometers, precision power supply and amplifier electronic circuits. The sensors fixed in a coplanar setup were separate by distance of 18 cm. The sensitivity tests had been carried through using a cylindrical magnet (ø = 4 mm and h = 4 mm) of neodymium-iron-boron (grid 35). The tests were done moving the permanent magnet on the sensors parallel axis, simulating the food transit in... (Complete abstract click electronic access below)
Resumo:
The market of digital games have grown in the last years, becoming popular between many ages, the number of smartphones and tablets users have also showed a recent increase, including the ones using Android as operational system. The main objective of a digital game is the ludic activity but also it can be used as a tool to education, learning and even simulation. This work proposes the development of a game for smartphones or tablet running on Android operational system, this game will simulate living beings in an environment, each one with different behaviors, based in the concepts of artificial live, cellular automata and emergence. This way simulating the behavior of a living being community with a computational base in artificial live and following concepts of game design. The game can represent visually some characteristics of living beings, as well behaviors and interactions between them, in a very simple way. The game can be upgraded in the future to represent better living beings using more details to the simulation of these