245 resultados para eficiência do uso da água


Relevância:

40.00% 40.00%

Publicador:

Resumo:

The use of refrigeration and air conditioning systems is of fundamental importance when it comes to air-conditioning of environments. Also important is the use of electricity for equipments’ operation related to these systems. Due to high cost of charging for this type of energy, factors economy and efficiency occupy key roles among design parameters of a system. One of the ways to get this economy is the use of a technique called thermal storage, or cold storage, which intends to move the required loads during peak time and also their equalizing, so that the energy is transferred from the peak time to non-peak time, thereby reducing the cost of energy consumed. Cold can be stored in the form of ice or ice water. This work aims to perform a technical-economic analysis of a mall located in Vale do Paraíba checking the feasibility of deploying a thermal storage system to achieve an economy in the cost of the energy used by the establishment. Through the parameters measured by the concessionaire of energy we can get the values of energy demand and power consumed, which will serve as basis for calculation for the study. The results obtained allow the development of two alternative proposals to the current configuration, one chosen by the criteria and results presented by technical-economic and energy analysis

Relevância:

40.00% 40.00%

Publicador:

Resumo:

In civil engineering, a structure is the whole sustainment of a construction and, thus, it is important that it remains intact throughout its lifetime. An engineering construction must last for decades without losing its functionality. However its purpose may be altered and several times the original structure does not meet the new needs of use. Still, in new buildings, the functionality is altered due to possible flaws in execution and the structure, invariably does not reach the desired solicitation needs. In cases like this, the commonly adopted solutions are, basically, the demolishment followed by the reconstruction of the desired mold or the structural reinforcement. This second option, for long years, has not been put to practice due to certain factors such as the high costs for its implantation, use of inadequate reinforcement execution techniques, and the culture of people involved in the area regarding its use and, in this case, the option would always be the reconstruction. Thoughtout the years, some techniques were developed to allow the execution of structural reinforcements with low costs and in efficient ways. An interesting, fast, efficient and economical technique is the structural reinforcement through metal sheets put together with epoxy resin that can be applied in beams, slabs and pillars. In the present work the different behavior of beams reinforced with this technique. Steel is a very recommended material for these reinforcements due to its characteristics related to traction, compression and the effectiveness of the technique related to its cost. For the attachment the epoxy resin is recommended, since it allows the joining of two materials, in this case, steel and concrete. The efficiency of this union is so considerably high that it rarely produces any flaws in adherence and, normally, when it happens it is due to problems in the execution process, not in the union of materials

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Water is an essential element for life. The use of this element, to support the community, defines it as water resource. This feature is being misused and degraded by the dumping of highly contaminated effluents. The impoverishment of its quality poses a risk to human consumption. The necessity to manage this resource, treating the wastewater properly, requires the constant improvement of treatment systems. Another need is to adjust the cost of systems to the demands of communities with less financial clout. This study aimed to adapt and understand the systems of wetlands, improving its efficiency, in an attempt to collaborate with the enrichment of this technology. The practical evidence, with lab-scale prototypes, assembled in ETE Piracicamirim with urban sewage effluent contributed to highlight the problems and operating system design. The bibliographic review showed that several studies had effectiveness for treatment. But it was evident the need for better understanding of dimensioning definitions that better attempted to the answers into the project. Moreover, standardization of system conditions for the specific wastewater treatment is an interesting field, identified, for future studies yet contribute to environmental engineering and sanitation

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The purpose of this project is to verify whether anaerobic reactors applied to sewage treatment are energetically self-sufficient. This evaluation can be made by balancing the methane produced through the anaerobic transformation stages (hydrolysis, acidogenesis, acetogenesis and methanogenesis) and the reactor energy consumption requirements. The original project included methanogenic activity tests, which could not be performed due to setbacks in the installation of an analytical instrument. Scientific articles about bench- and full-scale anaerobic reactors were investigated instead. An average substrate-to-methane conversion efficiency of 58,2±18,6% was found for the bench-scale reactors and higher efficiencies (89,2%) were found for the cases which had higher Organic Loading Rates (OLRs) values. The average energy output was 0,013 kWh/Lsewage, value unable to meet the energy needs for the reactor operation, considering equipments normally used such as temperature controller. This balance can become positive if few hypotheses are made, for example (i) to eliminate the use of temperature controller (ii) to alter the operation pattern from continuous to intermittent. Based on energy balance assessment of eight bench-scale reactors, it was observed that the implementation of a system for biogas utilization is not energetically feasible. However, interesting results were found for a full-scale sewage treatment plant, ETE Ouro Verde – Foz do Iguaçu, PR, Brazil. Even though its substrate-tomethane conversion efficiency was about 10% only, the energy balance was quite positive, with energy consumption of 68 kWh/month and energy production of 660 kWh/month. This analysis leads us to conclude that energy recovery from full-scale sewage treatment plants should be practiced by other plants

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Este projeto investigou alternativa de tratamento simplificada para fins não potáveis para aplicação em escala industrial. É neste contexto que esta pesquisa alojou sua importância – nas possíveis estratégias de tratamento, em especial na utilização de sistema contendo filtro de pressão e no uso do amido natural de milho como coagulante, auxiliando no processo de filtração, visando aumento da segurança sanitária e da qualidade da água de chuva disponibilizada para aproveitamento. A hipótese do trabalho foi investigar a possibilidade da diminuição ou até eliminação do volume de água descartada na operação de abstração da primeira chuva. Para tal, foram realizados ensaios em escala de laboratório com uma precipitação coletada nos dias 10/03/08 e 03/04/2008. Os resultados da estratégia de tratamento delineada foram comparados com os obtidos pela estratégia convencional com descarte de 1,5 mm da primeira chuva, o que corresponde a um volume de 558 L de água de chuva. Utilizou-se a dosagem de 6,0 mg/L para fim de comparação com a água bruta, sem nenhum tratamento, e com a água somente filtrada. Os resultados não confirmaram a hipótese de que o tratamento com amido natural permite eliminar a etapa de abstração da primeira chuva, porém, vale ressaltar que a qualidade da água coletada já era muito boa previamente ao tratamento. Merece destaque o fato de que a amostra de precipitação submetida aos ensaios apresentados foi coletada em período de freqüente precipitação e, embora tenha sido observado o interstício de 3 dias consecutivos de estiagem a qualidade da água de chuva coletada pode ser considerada boa (34UH de cor aparente; 8,84 UT de turbidez e 238,2 (NMP) de coliformes totais e 3 (NMP) de coliformes termotolerantes). Acredita-se que, para o caso de precipitações ocorridas após longo período de estiagem, a necessidade de tratamento... (Resumo completo, clicar acesso eletrônico abaixo)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Elétrica - FEIS

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Pós-graduação em Agronomia (Ciência do Solo) - FCAV

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Introduction: Currently, there are many questions regarding the cleaning methods seeking greater efficiency and less loss of burs. Aim: the aim of this study was to evaluate the influence of cleaning methods on the cutting efficiency and morphological characteristics of stainless steel burs tungsten carbide (carbide). Materials and method: Thirty burs were divided into five groups (n = 5) according with the cleaning method: L1 - steel brush, L2 - nylon brush, L3 - ultrasound  +  distilled water, L4 - ultrasound + descaling solution and L5 - no cleaning method (control). The burs were used for the cutting of bovine enamel during six periods of 12 minutes each. After each period, the burs were cleaned (except L5 ) following the protocol established for each group. The cutting efficiency was determined by mass loss and morphological characteristics. Result: The average amount of wear after 72 minutes of use were L1  = 0.3558 g; L2  = 0.4275 g; L3  = 0.4652 g; L4  = 0.4396 g e L5  = 0.4854 g; significant differences in the time of use (p  <  0.001) and cleaning method (p  <  0.001). The L1 group showed the worst performance. Regardless of the experimental group, morphological analysis revealed alterations in the cutting blades soon after the first 12 minutes, being L1 the most affected group. Conclusion: The cleaning with wire brush was the most damaging method to the cutting efficiency and to the morphology of carbide burs.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Mecânica - FEG

Relevância:

40.00% 40.00%

Publicador:

Resumo:

O objetivo do presente trabalho foi avaliar a eficiência do tratamento da manipueira de extração de fécula de mandioca, em separado da água de lavagem das raízes, através de biodigestores anaeróbicos de fluxo ascendente, com separação das fases, sem controle de temperatura ou adição de produtos químicos e, avaliar sua adequabilidade, através de suas características físicas e químicas para lançamento em corpo receptor, sistema público coletor de esgotos ou, aplicação em processod e fertirrigação. Depois dos reatores estabilizados, foram realizados ensaios variando a vazão de alimentação com 8,0; 12,0 e 16,0 L/d, correspondentes a um tempo de retenção hidráulica de 8,17; 5,44 e 4,08 dias, respectivamente. Os melhores resultados para redução da carga orgânica foram obtidos com os tempos de retenção hidráulica (TRH) de 8,17 e 5,44 dias com eficiências médias de 89,8% e 80,9%, respectivamente. As características físicas e químicas dos efluentes tratados foram comparadas com os valores estabelecidos na legislação estadual, federal e, com os parâmetros utilizados pelo orgão ambiental fiscalizador. Os resultados obtidos mostraram que o efluente tratado atende parcialmente aos requisitos legais para o lançamento em corpos receptores, devido ao teor elevado de nitrogênio amoniacal. Por outro lado, foram atendidos integralmente os requisitos legais para o lançamento na rede pública coletora de esgotos. O efluente tratado não atendeu às recomendações requeridas pelo orgão ambiental fiscalizador para a sua disposição através do processo de fertirrigação devido aos teores elevados de ferro (Fe) e de fluoretos (F). Considerando os resultados obtidos, concluímos que, devido à simplicidade do sistema utilizado, com a implantação de melhorias como um pós-tratamento, poderiam ser atingidos os parâmetros que atenderiam integralmente a legislação.