273 resultados para Tensile strength.


Relevância:

60.00% 60.00%

Publicador:

Resumo:

The waste, exaggerated and incorrect disposal of biomass are common practices in modern times where everything is disposable. However the growing concern with the nature and the environment compel man to give nobler destinations for these products through sustainability and recycling of waste. Banana peel is a residual biomass, which is not consumed. It generates tons of waste per week in São Paulo city. This trash is disposed in dumps and landfills, which could be reduced by using it as reinforcement in natural composites. The high density polyethylene (HDPE) is a polymer derived from the ethylene polymerization and is easily recycled. Which makes it a sustainable material. In the present work characteristics of the natural composite composed with banana peel and high-density polyethylene were studied. It was noted that removing the lignin present in the banana peel, the fiber introduces a significant improvement in thermal resistance. The preparation of composite was made with a ratio of 5% and 10% of reinforcement in comparison with polymeric matrix mass. Composites were thermally, mechanically and microscopically characterized. The addition of fiber in the polymer increased the mechanical strength of the composite. The fiber surface treatment with distilled water removed the amorphous material present in the fibers, improving significantly thermal stability and increasing crystallinity of the celullose. The addition of 5% fiber in mass to the polymer increased significantly the tensile strength and elasticity modulus for the composite. With 10% of fiber addiction there were also an improvement when compared with pure HDPE, but when compared with 5% composite the mechanical properties are slightly lower. This may be due to the fiber particle size, which are small and eventually become a hub of tension ... (Complete abstract click electronic access below)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In order to study the mechanical properties of micro alloyed steel API 5L X70, a material used to manufacture pipes for pipeline transportation lines for use in oil and gas, a study was made of toughness, tensile strength, impact strength, hardness and microstructure steel. To perform these various tests were made where they can acquire the characteristics of the material. Were performed at the Faculty of Engineering in Guaratinguetá in the Department of Materials and Technology and the tensile tests, Charpy impact test, metallography and hardness testing of material API 5L X70, all tests were done with the help of technical laboratories. With these data can be an analysis of the material about his tenacity, his toughness and fragility, its hardness, its yield strength and its maximum voltage. After being asked the analyzes discussed the results showed that the micro alloyed steel API 5L X70 steel is a very tenacious, it absorbs impact energy of 300 Joules though without a break for the full body of evidence showing its tenacity

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Civil - FEIS

Relevância:

60.00% 60.00%

Publicador:

Resumo:

By means of tensile strength, NiCr total crowns were removed from machine-made conical abutments composed by an Ti-6Al-4V alloy. In a total of 20 abutments, 10 were used with it surface presenting high smoothness and 10 abutments had its surfaces modifi ed by laser both cemented with zinc phosphate. The mechanical test was performed at a MTS 810 universal machine adjusted to a speed of 0.5 mm/m. The statistical analysis was done by Levene’s test, which showed homogeneity of variances among groups (F =2.21; p < 0.1). “Student t test” showed that signifi cant differences were found between groups. The modifi cation of the abutment surface through laser caused an increase in pull-out resistance of crowns cemented with zinc phosphate from 430.66 N to 1.514,87 N.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In this work of tensile strength was evaluated the efficacy of 4 cements (S. S. White zinc phoshate, Ketac Cem Easymix glass ionomer, RelyX Luting 2 composite resin/glass ionomer and Panavia 21 TC special acrylic resin) used to fix NiCr crowns to usinated titanium alloy abutments. Were used 40 abutments distributed in groups of 10 elements, to each material. The mechanical essays were developed at a MTS 810 universal machine, adjusted to a 0.5 mm/m velocity. The ANOVA applied to data pointed out the existence of significant differences between groups; the subsequent Tukey´s test (p<0.05) also detected significant differences, except at comparisons of phosphate versus RelyX and phosphate versus Ketac Cem. The better performance was presented by Panavia 21 (1,127.996 N); RelyX (478.197 N) showed itself similar only to phosphate (430.662 N), wich had a performance similar to that of Ketac Cem (227.705 N).

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Civil - FEIS

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Pós-graduação em Biociências - FCLAS

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Civil - FEIS

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The present study aimed to analyze the effects of tooth bleaching with 10% carbamide peroxide (CP) gel on the bond strength of resin composite restorations to dentin. Material and Methods: Twenty cavities were prepared on the buccal surface of bovine teeth. After acid etching and application of bonding agent on dentin and enamel, the cavities were restored with composite resin. The specimens were divided into groups according to treatment on the surface of enamel / restoration: G1 - control (no treatment) and G2 (10% PC gel application for 8h/day during 14 days). After this period, the teeth were cut to produce beams with 0.81 mm2 cross-sectional area, which were subjected to microtensile test. The fractures were examined with a stereomicroscope and classified as cohesive in resin or dentin, adhesive, or mixed. Results: The statistical analysis (ANOVA / χ2) revealed that the factor treatment interfered with the bond strength, which was significantly higher for specimens of G2 (p <0.05). Adhesive fractures occurred in most of specimens of both groups with values ranging from 48.3% to 75%. Mixed fractures were the second more frequent in G1 and cohesive resin failure in G2. Conclusion: It was concluded that tooth bleaching with 10% of PC increased the bond strength of adhesive restorations to dentin.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The purpose of this study was to use a fluorescent dye and CLSM microscope to observe the effect of different light intensities on dentin tensile bond strength. Flat dentin surfaces were created on 16 intact human third molars and divided in 4 groups: Group G1 - halogen - KM -200R®; Group G2 - LED - Ultraled®; Group G3 - LED - UltraLume LED5® and Group G4 - LED - Biolux Single V®. For all the groups, the restoration procedure used Single Bond® adhesive, mixed with rodamin B and InTen-S® composite resin. Then, they were cut on serial sections to obtain 1 mm2 area and submitted to micro tensile test and after words, the fractures were analyzed with a digital microscope and CLSM. The statistical analysis showed that all in all groups, except Group G2, which had a significant smaller tensile bond strength ratio. The fracture mode analysis showed that there were significant differences when comparing groups G1 / G2, and G2 / G4. There is no evidence of relevant differences among the other groups. With these results, we conclude that the use of fluorescent dye and CLSM demonstrated to be a simple and nondestructive technique, and that there are evidences that light intensities influenced the dentine tensile.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This study aimed to characterize and evaluate the performance of four models self-compensating drippers commonly used in drip irrigation systems in Brazil. To perform the study it was taking a sample of 25 emitters of each model. Evaluating their tubes (b) coefficient of manufacturing variation (c) wall thickness, (d) characteristic equation of the dripper, (e) internal diameter of the pipe, (f) spacing between emitters, (g) resistance water pressure at ambient temperature and to 40°C and (h) the tensile strength of the pipe with tension of 160 N and 180 N. The analysis showed variation coefficient of less than 0.045 for all manufacturing drippers (0.07 is maximum according to ABNT NBR ISO 9261). The exponents x of the equation pressure versus discharge ranged from 0.0082 to 0.0691 classifying them as self-compensating. From the results obtained it is clear that the tested products which are used in Brazil and used by irrigators had a satisfactory hydraulic performance in accordance with the standard.