278 resultados para Ruído de fase


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Schilder(1980) defines body image as the figuration of the body in your mind,ie to the way the body is presented to all. This image is constructed from six months in the infant´s contact with his mother by touch,thought the reflection of his image in the mirror and then in the contexto f activies préschool- didatic educator pedagogical proposes by consolidating the six years age. This importance of stdying the construction of body image pré-school educator is to prevent a failure in the process causing the child to change that image generating blocks and physical or psychological dificulties in the socialization process of children by promoting distortion of body image . O study objective is to understand how such package is the process of building up this image in preschool and your contribution to the process of learning of child. A methodology was a research review on amaig body, enconpassing the overall development of child and adult disorders the failure of the process constructive in this picture and a brief educational propose of how early childhood educator can work with this theme in pré-school. This study concluded that this topic is important to be working in the Field of education encompasses a degree in Physical Education and Pedagogy words.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Since discovery, computed tomography is a widely used diagnostic modality. However, this modality imparts relatively high doses to the patients and with fast technological advancement, it is necessary optimize the doses used and ensure the quality of the images through a quality assurance program. This work intended to compare Computed Tomography Dose Index (CTDIW) and effective dose with components of image quality: the Contrast-to-Noise Ratio (CNR) and Signal-to-Noise Ratio (SNR), and a quality factor (Q) deduced by the Rose model for two groups of computed tomography units. The first group was composed by equipments with 10 up to 16 slices and the second one presented 40 up to 320 slices detectors, for the protocols of head and abdomen. It was realized a comparison between different selectable parameters in the protocol of a Philips Brilliance 16, too. The results of the first group to CTDIW, effective dose, SNR and CNR showed variations of 28%, 33%, 37% and 32% respectively for head protocol, and 21%, 27%, 43% and 37% respectively for abdomen protocol. The results of the group 2 to CTDIW, effective dose, SNR and CNR showed variations of 15%, 26%, 36% and 34% respectively for the head protocol, and 8%, 13%, 50% and 60% respectively for abdomen protocol. The comparison between both groups demonstrated similar levels of doses impartation to patients though having so many different configurations, if the uncertainties associated with this measurement were considered. The results of the comparison between different parameters in the Philips Brilliance 16 scanner were in agreement with expected

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The signal-to-noise ratio and image uniformity analysis parameters are very important in quality control of an MRI scanner. They are measured in regular tests with phantoms. In these tests, however, used to quadrature coil, which has been most widely used clinically, and, therefore, was replaced in the procedures for body coil. In order to understand the difference between these two parameters in these coils, the study aimed to analyze the images acquired from four different phantoms in the same equipment under the same conditions for comparison purposes. With these results, it can be concluded that the body coil signal-to-noise ratio has always smaller than the quadrature in any projection, whereas the image uniformity is larger

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Of the four lacustrine deltaic models, which were found in the Pendência formation, two are represented in the Serraria field. Respectively the deltaic models 1 and 3 shows the reservoir zones A and B. The Zone A is divided into six sub-areas. Each is representing a smaller cycle of development of sigmoidal lobes of deltaic front. Zone B produces in reservoirs of Model 3, or so called Full delta. The Zone B is formed by overlapping the deltaic plain system over the deltaic/prodeltaic front (model 1). This work uses the method of zooming with the aim to contextualize the geometric aspects of the sand bodies, highlighting the analysis of facies and diagenesis with help of pictures and testimonies of thin sections. The sigmoidal lobes of Zone A are fine to very fine sandstones, well sorted, with a arcosian composition.;practically with a weak compaction and cementation of a kind of film of clay (if very fine) and overgrowth feldspar (fine texture). This silicate phases are succeeded by cementation of poiquilotópica calcite, and after this a stage of dissolution, containing only regular permoporosity for this reservoir. Zone B has a combination of two types of deltaic plain reservoir. One is the rarest of distributary channel and the other the most common of lobes of crevasse. In the channel coarse to medium-grained and poor to moderate sorted sandstones are formed (tuning up), and with a lytic arcosiana nature. Rarely there are cements, including growth of feldspar and rhombohedral dolomite, which prevent a high permoporosity of the reservoir. In the crevasse lobes, the sandstones are laminated, fine and well sorted, arkosic, rarely with overgrowth feldspar and calcite poiquilotópica, and with a good intergranular permoporosity

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the eld of synthetical materials, often called in the literature as organic/molecular conductors or charge-transfer salts, the most prominient examples are the quasi onedimensional systems (TMTTF)2X and (TMTSF)2X, where TMTTF, TMTSF and X refers to tetrametiltetratiafuvaline, tetrametiltetraselenafuvaline and a monovalent anion (X = PF6

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Considering the growing degradation of the urban environmental quality resulting from the progressive sound pollution increase, as well as the consequent harmful effects about the human health, the present study had its central objective the argument and management tools implementation of the urban noise that can be integrated to the environmental planning in the city of Rio Claro (SP). Therefore, normative and bibliographical revisions were developed, that made feasible the directives of control argument and prevention of the urban noise, as well as the technical procedures of sound levels and evaluation’s definition and especially about the criteria applicable for the elaboration of an urban acoustic zoning methodology. Among the main results obtained detach: (1) the applicable legislation to the management of urban noise’s synthesis and argument; (2) the methodology of urban acoustic zoning development and (3) its implementation to determined areas of Rio Claro (SP) with the (4) respective cartography representation; (5) the mapping of sound levels in the central zone of Rio Claro (SP), (6) the obtaining and analysis of noise describers (LAeq, Lmáx, L10, L50, L90, Lmin and TNI) and the subsequent (7) acoustic maps elaboration for the main describers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this study was to compare the power corresponding to maximal lactate steady state determined through continuous (MLSSC) and intermittent protocol with active recovery (MLSSI). Ten trained male cyclists (25 ± 4 yr, 72.5 ± 10.6 kg, 178.5 ± 4.0 cm), performed the following tests on different days on a cycle ergometer: (1) incremental test in order to determine the anaerobic threshold (AT) and maximal power (Pmax); (2) two to five constant workload tests to determine MLSSC, and; 3) two to three constant workload tests to determine MLSSI, consisting on 8 x 4 minutes bouts interspersed by two minutes of active recovery at 50% Pmax (i.e., 46 min of exercise protocol). MLSS intensity was defined as the highest workload at which blood lactate concentration did not increase by more than 1 mM between minutes 10 and 30 of the constant workload. The workload corresponding to MLSSC (273.2 ± 21.4 W) was significantly lower than that corresponding to MLSSI (300.5 ± 23.9 W). With base on these data, it can be verified that the intermittent exercise mode utilized in this study, allows an increase of 10% approximately, in the exercise intensity corresponding to MLSS.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A launching rocket and its payload are submitted to strong acoustic loads in some moments of its flight like lift off, during transonic flight and in the instant of maximum dynamic pressure. These loads could affect the payload and other rocket internal equipment. It must be taken into account that in the higher stages, where delicate control equipment and the payload are placed, the acoustic excitations are dominant. The knowledge of the acoustic loads is of great importance in order to provide estimated loads for the design phase, define intensity level to specify qualification and acceptation acoustic tests to which subsystems and elements of the launcher and its payload shall be submitted and to design an acoustic … (Complete abstract click electronic access below)